summaryrefslogtreecommitdiffstats
path: root/drivers/regulator
diff options
context:
space:
mode:
authorAxel Lin <axel.lin@ingics.com>2013-07-19 13:06:22 +0800
committerMark Brown <broonie@linaro.org>2013-07-19 19:08:37 +0100
commit6625d9d297f28741d42a4ba712338a05f7464bd6 (patch)
treeb03364d11eb0250c0449ec65c572507e1cf7dd75 /drivers/regulator
parent7c45f60b42e0f916aaf31fedf8e8afeaf585ee90 (diff)
downloadop-kernel-dev-6625d9d297f28741d42a4ba712338a05f7464bd6.zip
op-kernel-dev-6625d9d297f28741d42a4ba712338a05f7464bd6.tar.gz
regulator: 88pm800: Add missing n_voltages setting for bucks
Some regulator APIs are broken if n_voltages setting is not set. e.g. regulator_count_voltages(), regulator_list_voltage(), and regulator_can_change_voltage() do not work if n_voltages setting is missing. Signed-off-by: Axel Lin <axel.lin@ingics.com> Signed-off-by: Mark Brown <broonie@linaro.org>
Diffstat (limited to 'drivers/regulator')
-rw-r--r--drivers/regulator/88pm800.c14
1 files changed, 8 insertions, 6 deletions
diff --git a/drivers/regulator/88pm800.c b/drivers/regulator/88pm800.c
index fc0c352..b4c29b1 100644
--- a/drivers/regulator/88pm800.c
+++ b/drivers/regulator/88pm800.c
@@ -91,8 +91,9 @@ struct pm800_regulators {
* amax - the current
* Buck has 2 kinds of voltage steps. It is easy to find voltage by ranges,
* not the constant voltage table.
+ * n_volt - Number of available selectors
*/
-#define PM800_BUCK(vreg, ereg, ebit, amax, volt_ranges) \
+#define PM800_BUCK(vreg, ereg, ebit, amax, volt_ranges, n_volt) \
{ \
.desc = { \
.name = #vreg, \
@@ -100,6 +101,7 @@ struct pm800_regulators {
.type = REGULATOR_VOLTAGE, \
.id = PM800_ID_##vreg, \
.owner = THIS_MODULE, \
+ .n_voltages = n_volt, \
.linear_ranges = volt_ranges, \
.n_linear_ranges = ARRAY_SIZE(volt_ranges), \
.vsel_reg = PM800_##vreg, \
@@ -204,11 +206,11 @@ static struct regulator_ops pm800_volt_table_ops = {
/* The array is indexed by id(PM800_ID_XXX) */
static struct pm800_regulator_info pm800_regulator_info[] = {
- PM800_BUCK(BUCK1, BUCK_ENA, 0, 3000000, buck1_volt_range),
- PM800_BUCK(BUCK2, BUCK_ENA, 1, 1200000, buck2_5_volt_range),
- PM800_BUCK(BUCK3, BUCK_ENA, 2, 1200000, buck2_5_volt_range),
- PM800_BUCK(BUCK4, BUCK_ENA, 3, 1200000, buck2_5_volt_range),
- PM800_BUCK(BUCK5, BUCK_ENA, 4, 1200000, buck2_5_volt_range),
+ PM800_BUCK(BUCK1, BUCK_ENA, 0, 3000000, buck1_volt_range, 0x55),
+ PM800_BUCK(BUCK2, BUCK_ENA, 1, 1200000, buck2_5_volt_range, 0x73),
+ PM800_BUCK(BUCK3, BUCK_ENA, 2, 1200000, buck2_5_volt_range, 0x73),
+ PM800_BUCK(BUCK4, BUCK_ENA, 3, 1200000, buck2_5_volt_range, 0x73),
+ PM800_BUCK(BUCK5, BUCK_ENA, 4, 1200000, buck2_5_volt_range, 0x73),
PM800_LDO(LDO1, LDO_ENA1_1, 0, 200000, ldo1_volt_table),
PM800_LDO(LDO2, LDO_ENA1_1, 1, 10000, ldo2_volt_table),
OpenPOWER on IntegriCloud