diff options
author | Axel Lin <axel.lin@ingics.com> | 2013-04-17 21:42:23 +0800 |
---|---|---|
committer | Mark Brown <broonie@opensource.wolfsonmicro.com> | 2013-04-23 11:47:37 +0100 |
commit | 58fa6ab42c29156b2808f8db231b2ffd8fa25502 (patch) | |
tree | a8e34ac587ff6024813f8a6996627c133b9089c4 /drivers/regulator/dbx500-prcmu.h | |
parent | 41ef2d5678d83af030125550329b6ae8b74618fa (diff) | |
download | op-kernel-dev-58fa6ab42c29156b2808f8db231b2ffd8fa25502.zip op-kernel-dev-58fa6ab42c29156b2808f8db231b2ffd8fa25502.tar.gz |
regulator: tps80031: Fix LDO2 track mode for TPS80031 or TPS80032-ES1.0
Currently we have a special code in tps80031_ldo_set_voltage_sel() to handle
LDO2 track mode for TPS80031 or TPS80032-ES1.0. The purpose is to address below
issues:
Issue description:
- LDO2 traking mode is enabled
- LDO2 tracks SMPS2 voltage.
- LDO2 automatically switch-off when LDO2_CFG_VOLTAGE is changed to some discrete values (non exhaustive list):
00011001, 00011010, 00011011, 00011100, .
- LDO2 switch-on again when LDO2_CFG_VOLTAGE is changed to other values (non exhaustive list):
00011000, 00010111, .
LDOs have reserved codes. For these codes, LDO is switch-off.
In tracking, LDO2 ref comes from SMPS2.
However LDO2 enable is still gated by LDO2 VSEL decoding.
As a result, in tracking mode LDO2 will be disabled for following code (SMPS VSEL format):
000000 & 100000 (MSB not decoded)
011001 & 111001 (MSB not decoded)
011010 & 111010 (MSB not decoded)
011100 & 111100 (MSB not decoded)
011101 & 111101 (MSB not decoded)
011110 & 111110 (MSB not decoded)
However, current code has below bugs:
1. It uses regulator_list_voltage_linear, so list_voltage() still shows above
invalid selectors have supported voltage.
2. Current code may return -EINVAL in tps80031_ldo_set_voltage_sel() for
supported voltage. This is because when we use regulator_list_voltage_linear
as list_voltage callback, regulator core will default use
regulator_map_voltage_linear(). regulator_map_voltage_linear() has an
assumption that the voltages are linear which is not true for this case.
For example,
when request voltage range is: min_uV=950000 uV && max_uV=1200000 uV
regulator_map_voltage_linear() returns the selector is 29 (0x1D),
set_voltage_sel() returns -EINVAL.
(The selector is in invalid range, 0x19 ~ 0x1f).
In above case, map_voltage() should find the lowest valid voltage within
specific range (selector = 0x20) and set_voltage_sel() should successfully
set the voltage to 987500 uV.
This patch fixes these issues by:
1. Add checking valid setting for LDO2 track mode of TPS80031 or TPS80032-ES1.0
in list_voltage. So it returns -EINVAL for invalid selectors.
2. Implement tps80031_ldo_map_voltage, use regulator_map_voltage_iterate()
to find the lowest voltage within specific range for TPS80031 or
TPS80032-ES1.0. This is required when the voltage map is no longer linear.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Diffstat (limited to 'drivers/regulator/dbx500-prcmu.h')
0 files changed, 0 insertions, 0 deletions