ab8500_btemp: Get rid of 'enum adc_therm'
This is the same as abx500_adc_therm, but when the former is used, the following warning flood pops up: drivers/power/ab8500_btemp.c: In function 'ab8500_btemp_batctrl_volt_to_res': ab8500_btemp.c:150:25: warning: comparison between 'enum abx500_adc_therm' and 'enum adc_therm' [-Wenum-compare] ab8500_btemp.c: In function 'ab8500_btemp_curr_source_enable': ab8500_btemp.c:212:25: warning: comparison between 'enum abx500_adc_therm' and 'enum adc_therm' [-Wenum-compare] ab8500_btemp.c:244:32: warning: comparison between 'enum abx500_adc_therm' and 'enum adc_therm' [-Wenum-compare] ab8500_btemp.c: In function 'ab8500_btemp_measure_temp': ab8500_btemp.c:462:25: warning: comparison between 'enum abx500_adc_therm' and 'enum adc_therm' [-Wenum-compare] ab8500_btemp.c: In function 'ab8500_btemp_id': ab8500_btemp.c:528:121: warning: comparison between 'enum abx500_adc_therm' and 'enum adc_therm' [-Wenum-compare] ab8500_btemp.c:551:25: warning: comparison between 'enum abx500_adc_therm' and 'enum adc_therm' [-Wenum-compare] This patch fixes the issue by switching the driver to use more namespace-friendly enum. Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/ab8500_btemp.c13
1 files changed, 7 insertions, 6 deletions
diff --git a/drivers/power/ab8500_btemp.c b/drivers/power/ab8500_btemp.c
index 443bc7d..d8bb993 100644
--- a/drivers/power/ab8500_btemp.c
+++ b/drivers/power/ab8500_btemp.c
@@ -147,7 +147,7 @@ static int ab8500_btemp_batctrl_volt_to_res(struct ab8500_btemp *di,
return (450000 * (v_batctrl)) / (1800 - v_batctrl);
}
- if (di->bat->adc_therm == ADC_THERM_BATCTRL) {
+ if (di->bat->adc_therm == ABx500_ADC_THERM_BATCTRL) {
/*
* If the battery has internal NTC, we use the current
* source to calculate the resistance, 7uA or 20uA
@@ -209,7 +209,7 @@ static int ab8500_btemp_curr_source_enable(struct ab8500_btemp *di,
return 0;
/* Only do this for batteries with internal NTC */
- if (di->bat->adc_therm == ADC_THERM_BATCTRL && enable) {
+ if (di->bat->adc_therm == ABx500_ADC_THERM_BATCTRL && enable) {
if (di->curr_source == BTEMP_BATCTRL_CURR_SRC_7UA)
curr = BAT_CTRL_7U_ENA;
else
@@ -241,7 +241,7 @@ static int ab8500_btemp_curr_source_enable(struct ab8500_btemp *di,
__func__);
goto disable_curr_source;
}
- } else if (di->bat->adc_therm == ADC_THERM_BATCTRL && !enable) {
+ } else if (di->bat->adc_therm == ABx500_ADC_THERM_BATCTRL && !enable) {
dev_dbg(di->dev, "Disable BATCTRL curr source\n");
/* Write 0 to the curr bits */
@@ -459,7 +459,7 @@ static int ab8500_btemp_measure_temp(struct ab8500_btemp *di)
id = di->bat->batt_id;
- if (di->bat->adc_therm == ADC_THERM_BATCTRL &&
+ if (di->bat->adc_therm == ABx500_ADC_THERM_BATCTRL &&
id != BATTERY_UNKNOWN) {
rbat = ab8500_btemp_get_batctrl_res(di);
@@ -528,7 +528,7 @@ static int ab8500_btemp_id(struct ab8500_btemp *di)
dev_dbg(di->dev, "Battery detected on %s"
" low %d < res %d < high: %d"
" index: %d\n",
- di->bat->adc_therm == ADC_THERM_BATCTRL ?
+ di->bat->adc_therm == ABx500_ADC_THERM_BATCTRL ?
"BATCTRL" : "BATTEMP",
di->bat->bat_type[i].resis_low, res,
di->bat->bat_type[i].resis_high, i);
@@ -548,7 +548,8 @@ static int ab8500_btemp_id(struct ab8500_btemp *di)
* We only have to change current source if the
* detected type is Type 1, else we use the 7uA source
*/
- if (di->bat->adc_therm == ADC_THERM_BATCTRL && di->bat->batt_id == 1) {
+ if (di->bat->adc_therm == ABx500_ADC_THERM_BATCTRL &&
+ di->bat->batt_id == 1) {
dev_dbg(di->dev, "Set BATCTRL current source to 20uA\n");
di->curr_source = BTEMP_BATCTRL_CURR_SRC_20UA;
}
OpenPOWER on IntegriCloud