authorLinus Torvalds <torvalds@woody.linux-foundation.org>2007-10-22 19:20:52 -0700
committerLinus Torvalds <torvalds@woody.linux-foundation.org>2007-10-22 19:20:52 -0700
commit0c326331c8b107abc0a160e8899d749150b8f76a (patch)
tree186df49fe26b66ca7c003d26152ef734a5ff35fd /drivers/power
parentad792f4f46e12bae58298fc64f5139b99664a773 (diff)
parent2a721dfc8c677588fc98d818dfad3354081c6ddb (diff)
downloadop-kernel-dev-0c326331c8b107abc0a160e8899d749150b8f76a.zip
op-kernel-dev-0c326331c8b107abc0a160e8899d749150b8f76a.tar.gz
Merge git://git.infradead.org/battery-2.6
* git://git.infradead.org/battery-2.6: apm_power: calculate to_full/to_empty time using energy apm_power: improve battery finding algorithm apm_power: fix obviously wrong logic for time reporting
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/apm_power.c141
1 files changed, 102 insertions, 39 deletions
diff --git a/drivers/power/apm_power.c b/drivers/power/apm_power.c
index 39a90a6..bbf3ee1 100644
--- a/drivers/power/apm_power.c
+++ b/drivers/power/apm_power.c
@@ -26,65 +26,124 @@ static struct power_supply *main_battery;
static void find_main_battery(void)
{
struct device *dev;
- struct power_supply *bat, *batm;
+ struct power_supply *bat = NULL;
+ struct power_supply *max_charge_bat = NULL;
+ struct power_supply *max_energy_bat = NULL;
union power_supply_propval full;
int max_charge = 0;
+ int max_energy = 0;
main_battery = NULL;
- batm = NULL;
+
list_for_each_entry(dev, &power_supply_class->devices, node) {
bat = dev_get_drvdata(dev);
- /* If none of battery devices cantains 'use_for_apm' flag,
- choice one with maximum design charge */
- if (!PSY_PROP(bat, CHARGE_FULL_DESIGN, &full)) {
+
+ if (bat->use_for_apm) {
+ /* nice, we explicitly asked to report this battery. */
+ main_battery = bat;
+ return;
+ }
+
+ if (!PSY_PROP(bat, CHARGE_FULL_DESIGN, &full) ||
+ !PSY_PROP(bat, CHARGE_FULL, &full)) {
if (full.intval > max_charge) {
- batm = bat;
+ max_charge_bat = bat;
max_charge = full.intval;
}
+ } else if (!PSY_PROP(bat, ENERGY_FULL_DESIGN, &full) ||
+ !PSY_PROP(bat, ENERGY_FULL, &full)) {
+ if (full.intval > max_energy) {
+ max_energy_bat = bat;
+ max_energy = full.intval;
+ }
}
+ }
- if (bat->use_for_apm)
- main_battery = bat;
+ if ((max_energy_bat && max_charge_bat) &&
+ (max_energy_bat != max_charge_bat)) {
+ /* try guess battery with more capacity */
+ if (!PSY_PROP(max_charge_bat, VOLTAGE_MAX_DESIGN, &full)) {
+ if (max_energy > max_charge * full.intval)
+ main_battery = max_energy_bat;
+ else
+ main_battery = max_charge_bat;
+ } else if (!PSY_PROP(max_energy_bat, VOLTAGE_MAX_DESIGN,
+ &full)) {
+ if (max_charge > max_energy / full.intval)
+ main_battery = max_charge_bat;
+ else
+ main_battery = max_energy_bat;
+ } else {
+ /* give up, choice any */
+ main_battery = max_energy_bat;
+ }
+ } else if (max_charge_bat) {
+ main_battery = max_charge_bat;
+ } else if (max_energy_bat) {
+ main_battery = max_energy_bat;
+ } else {
+ /* give up, try the last if any */
+ main_battery = bat;
}
- if (!main_battery)
- main_battery = batm;
}
-static int calculate_time(int status)
+static int calculate_time(int status, int using_charge)
{
- union power_supply_propval charge_full, charge_empty;
- union power_supply_propval charge, I;
+ union power_supply_propval full;
+ union power_supply_propval empty;
+ union power_supply_propval cur;
+ union power_supply_propval I;
+ enum power_supply_property full_prop;
+ enum power_supply_property full_design_prop;
+ enum power_supply_property empty_prop;
+ enum power_supply_property empty_design_prop;
+ enum power_supply_property cur_avg_prop;
+ enum power_supply_property cur_now_prop;
- if (MPSY_PROP(CHARGE_FULL, &charge_full)) {
- /* if battery can't report this property, use design value */
- if (MPSY_PROP(CHARGE_FULL_DESIGN, &charge_full))
+ if (MPSY_PROP(CURRENT_AVG, &I)) {
+ /* if battery can't report average value, use momentary */
+ if (MPSY_PROP(CURRENT_NOW, &I))
return -1;
}
- if (MPSY_PROP(CHARGE_EMPTY, &charge_empty)) {
- /* if battery can't report this property, use design value */
- if (MPSY_PROP(CHARGE_EMPTY_DESIGN, &charge_empty))
- charge_empty.intval = 0;
+ if (using_charge) {
+ full_prop = POWER_SUPPLY_PROP_CHARGE_FULL;
+ full_design_prop = POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN;
+ empty_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
+ empty_design_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
+ cur_avg_prop = POWER_SUPPLY_PROP_CHARGE_AVG;
+ cur_now_prop = POWER_SUPPLY_PROP_CHARGE_NOW;
+ } else {
+ full_prop = POWER_SUPPLY_PROP_ENERGY_FULL;
+ full_design_prop = POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN;
+ empty_prop = POWER_SUPPLY_PROP_ENERGY_EMPTY;
+ empty_design_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
+ cur_avg_prop = POWER_SUPPLY_PROP_ENERGY_AVG;
+ cur_now_prop = POWER_SUPPLY_PROP_ENERGY_NOW;
}
- if (MPSY_PROP(CHARGE_AVG, &charge)) {
- /* if battery can't report average value, use momentary */
- if (MPSY_PROP(CHARGE_NOW, &charge))
+ if (_MPSY_PROP(full_prop, &full)) {
+ /* if battery can't report this property, use design value */
+ if (_MPSY_PROP(full_design_prop, &full))
return -1;
}
- if (MPSY_PROP(CURRENT_AVG, &I)) {
+ if (_MPSY_PROP(empty_prop, &empty)) {
+ /* if battery can't report this property, use design value */
+ if (_MPSY_PROP(empty_design_prop, &empty))
+ empty.intval = 0;
+ }
+
+ if (_MPSY_PROP(cur_avg_prop, &cur)) {
/* if battery can't report average value, use momentary */
- if (MPSY_PROP(CURRENT_NOW, &I))
+ if (_MPSY_PROP(cur_now_prop, &cur))
return -1;
}
if (status == POWER_SUPPLY_STATUS_CHARGING)
- return ((charge.intval - charge_full.intval) * 60L) /
- I.intval;
+ return ((cur.intval - full.intval) * 60L) / I.intval;
else
- return -((charge.intval - charge_empty.intval) * 60L) /
- I.intval;
+ return -((cur.intval - empty.intval) * 60L) / I.intval;
}
static int calculate_capacity(int using_charge)
@@ -200,18 +259,22 @@ static void apm_battery_apm_get_power_status(struct apm_power_info *info)
info->units = APM_UNITS_MINS;
if (status.intval == POWER_SUPPLY_STATUS_CHARGING) {
- if (MPSY_PROP(TIME_TO_FULL_AVG, &time_to_full)) {
- if (MPSY_PROP(TIME_TO_FULL_NOW, &time_to_full))
- info->time = calculate_time(status.intval);
- else
- info->time = time_to_full.intval / 60;
+ if (!MPSY_PROP(TIME_TO_FULL_AVG, &time_to_full) ||
+ !MPSY_PROP(TIME_TO_FULL_NOW, &time_to_full)) {
+ info->time = time_to_full.intval / 60;
+ } else {
+ info->time = calculate_time(status.intval, 0);
+ if (info->time == -1)
+ info->time = calculate_time(status.intval, 1);
}
} else {
- if (MPSY_PROP(TIME_TO_EMPTY_AVG, &time_to_empty)) {
- if (MPSY_PROP(TIME_TO_EMPTY_NOW, &time_to_empty))
- info->time = calculate_time(status.intval);
- else
- info->time = time_to_empty.intval / 60;
+ if (!MPSY_PROP(TIME_TO_EMPTY_AVG, &time_to_empty) ||
+ !MPSY_PROP(TIME_TO_EMPTY_NOW, &time_to_empty)) {
+ info->time = time_to_empty.intval / 60;
+ } else {
+ info->time = calculate_time(status.intval, 0);
+ if (info->time == -1)
+ info->time = calculate_time(status.intval, 1);
}
}
OpenPOWER on IntegriCloud