summaryrefslogtreecommitdiffstats
path: root/drivers/power
diff options
context:
space:
mode:
authorRamakrishna Pallala <ramakrishna.pallala@intel.com>2012-05-05 21:33:54 +0530
committerAnton Vorontsov <anton.vorontsov@linaro.org>2012-05-06 04:46:18 -0700
commitfcc015cda7dfe1af26e17bbed21eecb742183b7e (patch)
treeb7121101f98a6beb33213a381174097f48d98ef0 /drivers/power
parent9a8422d205ea142a27c2573e5ca3d2cc87d75260 (diff)
downloadop-kernel-dev-fcc015cda7dfe1af26e17bbed21eecb742183b7e.zip
op-kernel-dev-fcc015cda7dfe1af26e17bbed21eecb742183b7e.tar.gz
smb347-charger: Clean up battery attributes
CURRENT_NOW and VOLTAGE_NOW should be instantaneous readings from power supply(ex: battery). smb347 charger driver reports charge voltage for VOLTAGE_NOW and charge current for CURRENT_NOW attributes which are not instantaneous readings. This patch removes the battery VOLTAGE_NOW and CURRENT_NOW properties from the driver and also removes hw_to_current() which is not required anymore. Signed-off-by: Ramakrishna Pallala <ramakrishna.pallala@intel.com> Acked-by: Mika Westerberg <mika.westerberg@linux.intel.com> Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/smb347-charger.c49
1 files changed, 0 insertions, 49 deletions
diff --git a/drivers/power/smb347-charger.c b/drivers/power/smb347-charger.c
index cf31b31..09d19d2 100644
--- a/drivers/power/smb347-charger.c
+++ b/drivers/power/smb347-charger.c
@@ -195,14 +195,6 @@ static const unsigned int ccc_tbl[] = {
1200000,
};
-/* Convert register value to current using lookup table */
-static int hw_to_current(const unsigned int *tbl, size_t size, unsigned int val)
-{
- if (val >= size)
- return -EINVAL;
- return tbl[val];
-}
-
/* Convert current to register value using lookup table */
static int current_to_hw(const unsigned int *tbl, size_t size, unsigned int val)
{
@@ -891,7 +883,6 @@ static int smb347_battery_get_property(struct power_supply *psy,
struct smb347_charger *smb =
container_of(psy, struct smb347_charger, battery);
const struct smb347_charger_platform_data *pdata = smb->pdata;
- unsigned int v;
int ret;
ret = smb347_update_ps_status(smb);
@@ -943,44 +934,6 @@ static int smb347_battery_get_property(struct power_supply *psy,
val->intval = pdata->battery_info.voltage_max_design;
break;
- case POWER_SUPPLY_PROP_VOLTAGE_NOW:
- if (!smb347_is_ps_online(smb))
- return -ENODATA;
- ret = regmap_read(smb->regmap, STAT_A, &v);
- if (ret < 0)
- return ret;
-
- v &= STAT_A_FLOAT_VOLTAGE_MASK;
- if (v > 0x3d)
- v = 0x3d;
-
- val->intval = 3500000 + v * 20000;
- break;
-
- case POWER_SUPPLY_PROP_CURRENT_NOW:
- if (!smb347_is_ps_online(smb))
- return -ENODATA;
-
- ret = regmap_read(smb->regmap, STAT_B, &v);
- if (ret < 0)
- return ret;
-
- /*
- * The current value is composition of FCC and PCC values
- * and we can detect which table to use from bit 5.
- */
- if (v & 0x20) {
- val->intval = hw_to_current(fcc_tbl,
- ARRAY_SIZE(fcc_tbl),
- v & 7);
- } else {
- v >>= 3;
- val->intval = hw_to_current(pcc_tbl,
- ARRAY_SIZE(pcc_tbl),
- v & 7);
- }
- break;
-
case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
val->intval = pdata->battery_info.charge_full_design;
break;
@@ -1002,8 +955,6 @@ static enum power_supply_property smb347_battery_properties[] = {
POWER_SUPPLY_PROP_TECHNOLOGY,
POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN,
POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
- POWER_SUPPLY_PROP_VOLTAGE_NOW,
- POWER_SUPPLY_PROP_CURRENT_NOW,
POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
POWER_SUPPLY_PROP_MODEL_NAME,
};
OpenPOWER on IntegriCloud