authorTejun Heo <tj@kernel.org>2009-09-22 17:34:48 +0900
committerJesse Barnes <jbarnes@virtuousgeek.org>2009-11-04 08:47:11 -0800
commit15ea76d407d560f985224b65fe59c9db01692a0d (patch)
treedd9dd1cd4cab4bff26c34853a1c67898e8500243 /drivers/pcmcia
parent4c0eec7a86303ce6e3edf7825d0ef1d414e76767 (diff)
downloadop-kernel-dev-15ea76d407d560f985224b65fe59c9db01692a0d.zip
op-kernel-dev-15ea76d407d560f985224b65fe59c9db01692a0d.tar.gz
pccard: configure CLS on attach
For non hotplug PCI devices, the system firmware usually configures CLS correctly. For pccard devices system firmware can't do it and Linux PCI layer doesn't do it either. Unfortunately this leads to poor performance for certain devices (sata_sil). Unless MWI, which requires separate configuration, is to be used, CLS doesn't affect correctness, so the configuration should be harmless. This patch makes pci_set_cacheline_size() always built and export it and make pccard call it during attach. Please note that some other PCI hotplug drivers (shpchp and pciehp) also configure CLS on hotplug. Signed-off-by: Tejun Heo <tj@kernel.org> Cc: Daniel Ritz <daniel.ritz@gmx.ch> Cc: Dominik Brodowski <linux@dominikbrodowski.net> Cc: Greg KH <greg@kroah.com> Cc: Kenji Kaneshige <kaneshige.kenji@jp.fujitsu.com> Cc: Axel Birndt <towerlexa@gmx.de> Signed-off-by: Jesse Barnes <jbarnes@virtuousgeek.org>
Diffstat (limited to 'drivers/pcmcia')
-rw-r--r--drivers/pcmcia/cardbus.c23
1 files changed, 15 insertions, 8 deletions
diff --git a/drivers/pcmcia/cardbus.c b/drivers/pcmcia/cardbus.c
index db77e1f..98789c0 100644
--- a/drivers/pcmcia/cardbus.c
+++ b/drivers/pcmcia/cardbus.c
@@ -184,26 +184,33 @@ fail:
=====================================================================*/
-/*
- * Since there is only one interrupt available to CardBus
- * devices, all devices downstream of this device must
- * be using this IRQ.
- */
-static void cardbus_assign_irqs(struct pci_bus *bus, int irq)
+static void cardbus_config_irq_and_cls(struct pci_bus *bus, int irq)
{
struct pci_dev *dev;
list_for_each_entry(dev, &bus->devices, bus_list) {
u8 irq_pin;
+ /*
+ * Since there is only one interrupt available to
+ * CardBus devices, all devices downstream of this
+ * device must be using this IRQ.
+ */
pci_read_config_byte(dev, PCI_INTERRUPT_PIN, &irq_pin);
if (irq_pin) {
dev->irq = irq;
pci_write_config_byte(dev, PCI_INTERRUPT_LINE, dev->irq);
}
+ /*
+ * Some controllers transfer very slowly with 0 CLS.
+ * Configure it. This may fail as CLS configuration
+ * is mandatory only for MWI.
+ */
+ pci_set_cacheline_size(dev);
+
if (dev->subordinate)
- cardbus_assign_irqs(dev->subordinate, irq);
+ cardbus_config_irq_and_cls(dev->subordinate, irq);
}
}
@@ -228,7 +235,7 @@ int __ref cb_alloc(struct pcmcia_socket * s)
*/
pci_bus_size_bridges(bus);
pci_bus_assign_resources(bus);
- cardbus_assign_irqs(bus, s->pci_irq);
+ cardbus_config_irq_and_cls(bus, s->pci_irq);
/* socket specific tune function */
if (s->tune_bridge)
OpenPOWER on IntegriCloud