summaryrefslogtreecommitdiffstats
path: root/drivers/net/wireless
diff options
context:
space:
mode:
authorEmmanuel Grumbach <emmanuel.grumbach@intel.com>2013-11-05 16:27:59 +0200
committerEmmanuel Grumbach <emmanuel.grumbach@intel.com>2013-11-25 23:00:20 +0200
commit9fc3fe96c36ca26f1cf028ded9ee41c47d9e9d4a (patch)
treea1004b66d0b7cc6d158fe135b7c4fa0cf77158ec /drivers/net/wireless
parent56c07a9c95afa93c089824cb02bf4133ca4eb180 (diff)
downloadop-kernel-dev-9fc3fe96c36ca26f1cf028ded9ee41c47d9e9d4a.zip
op-kernel-dev-9fc3fe96c36ca26f1cf028ded9ee41c47d9e9d4a.tar.gz
iwlwifi: mvm: don't WARN about unsuccessful time event
Time event notification can have a failure status even if the time event was scheduled: * in START notification, this can happen if the time event was scheduled later than the requested apply time. * in STOP notification, this can happen if the time event is truncated. Even if both happened, the offchannel packets sent during the remain on channel are very likely to have been sent. Hence, don't WARN when this happens, but rather print a discrete line in the kernel log. Signed-off-by: Emmanuel Grumbach <emmanuel.grumbach@intel.com> Reviewed-by: Johannes Berg <johannes.berg@intel.com>
Diffstat (limited to 'drivers/net/wireless')
-rw-r--r--drivers/net/wireless/iwlwifi/mvm/time-event.c7
1 files changed, 5 insertions, 2 deletions
diff --git a/drivers/net/wireless/iwlwifi/mvm/time-event.c b/drivers/net/wireless/iwlwifi/mvm/time-event.c
index 33cf56f..95ce4b6 100644
--- a/drivers/net/wireless/iwlwifi/mvm/time-event.c
+++ b/drivers/net/wireless/iwlwifi/mvm/time-event.c
@@ -176,8 +176,11 @@ static void iwl_mvm_te_handle_notif(struct iwl_mvm *mvm,
* P2P Device discoveribility, while there are other higher priority
* events in the system).
*/
- if (WARN_ONCE(!le32_to_cpu(notif->status),
- "Failed to schedule time event\n")) {
+ if (!le32_to_cpu(notif->status)) {
+ bool start = le32_to_cpu(notif->action) &
+ TE_V2_NOTIF_HOST_EVENT_START;
+ IWL_WARN(mvm, "Time Event %s notification failure\n",
+ start ? "start" : "end");
if (iwl_mvm_te_check_disconnect(mvm, te_data->vif, NULL)) {
iwl_mvm_te_clear_data(mvm, te_data);
return;