[TG3]: Prescaler fix
Internal hardware timers become inaccurate after link events. Clock frequency switches performed by the CPMU fail to adjust timer prescalers. The fix is to detect core clock frequency changes during link events and adjust the timer prescalers accordingly. Signed-off-by: Matt Carlson <mcarlson@broadcom.com> Signed-off-by: Michael Chan <mchan@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/tg3.c')
-rw-r--r--drivers/net/tg3.c16
1 files changed, 16 insertions, 0 deletions
diff --git a/drivers/net/tg3.c b/drivers/net/tg3.c
index bb3b734..ecd64a22 100644
--- a/drivers/net/tg3.c
+++ b/drivers/net/tg3.c
@@ -3154,6 +3154,22 @@ static int tg3_setup_phy(struct tg3 *tp, int force_reset)
err = tg3_setup_copper_phy(tp, force_reset);
}
+ if (tp->pci_chip_rev_id == CHIPREV_ID_5784_A0) {
+ u32 val, scale;
+
+ val = tr32(TG3_CPMU_CLCK_STAT) & CPMU_CLCK_STAT_MAC_CLCK_MASK;
+ if (val == CPMU_CLCK_STAT_MAC_CLCK_62_5)
+ scale = 65;
+ else if (val == CPMU_CLCK_STAT_MAC_CLCK_6_25)
+ scale = 6;
+ else
+ scale = 12;
+
+ val = tr32(GRC_MISC_CFG) & ~GRC_MISC_CFG_PRESCALAR_MASK;
+ val |= (scale << GRC_MISC_CFG_PRESCALAR_SHIFT);
+ tw32(GRC_MISC_CFG, val);
+ }
+
if (tp->link_config.active_speed == SPEED_1000 &&
tp->link_config.active_duplex == DUPLEX_HALF)
tw32(MAC_TX_LENGTHS,