summaryrefslogtreecommitdiffstats
path: root/drivers/net/s2io.h
diff options
context:
space:
mode:
authorAnanda Raju <Ananda.Raju@neterion.com>2005-10-31 16:55:31 -0500
committerJeff Garzik <jgarzik@pobox.com>2005-11-05 14:40:27 -0500
commitda6971d8ece2ec9762509e20dda6808335b5a10b (patch)
tree9ae532e7ab6314400fb601f6b7c5e6042166429f /drivers/net/s2io.h
parent29b09fcc341ede8dc08c900b132903fdd0231400 (diff)
downloadop-kernel-dev-da6971d8ece2ec9762509e20dda6808335b5a10b.zip
op-kernel-dev-da6971d8ece2ec9762509e20dda6808335b5a10b.tar.gz
[PATCH] S2io: Multi buffer mode support
Hi, This patch provides dynamic two buffer-mode and 3 buffer-mode options. Previously 2 buffer-mode was compilation option. Now with this patch applied one can load driver in 2 buffer-mode with module-load parameter ie. #insmod s2io.ko rx_ring_mode=2 This patch also provides 3 buffer-mode which provides header separation functionality. In 3 buffer-mode skb->data will have L2/L3/L4 headers and "skb_shinfo(skb)->frag_list->data" will have have L4 payload. one can load driver in 3 buffer-mode with same above module-load parameter ie. #insmod s2io.ko rx_ring_mode=3 Please review the patch. Signed-off-by: Ananda Raju <ananda.raju@neterion.com> Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
Diffstat (limited to 'drivers/net/s2io.h')
-rw-r--r--drivers/net/s2io.h91
1 files changed, 47 insertions, 44 deletions
diff --git a/drivers/net/s2io.h b/drivers/net/s2io.h
index 1cc24b5..419aad7 100644
--- a/drivers/net/s2io.h
+++ b/drivers/net/s2io.h
@@ -418,7 +418,7 @@ typedef struct list_info_hold {
void *list_virt_addr;
} list_info_hold_t;
-/* Rx descriptor structure */
+/* Rx descriptor structure for 1 buffer mode */
typedef struct _RxD_t {
u64 Host_Control; /* reserved for host */
u64 Control_1;
@@ -439,49 +439,54 @@ typedef struct _RxD_t {
#define SET_RXD_MARKER vBIT(THE_RXD_MARK, 0, 2)
#define GET_RXD_MARKER(ctrl) ((ctrl & SET_RXD_MARKER) >> 62)
-#ifndef CONFIG_2BUFF_MODE
-#define MASK_BUFFER0_SIZE vBIT(0x3FFF,2,14)
-#define SET_BUFFER0_SIZE(val) vBIT(val,2,14)
-#else
-#define MASK_BUFFER0_SIZE vBIT(0xFF,2,14)
-#define MASK_BUFFER1_SIZE vBIT(0xFFFF,16,16)
-#define MASK_BUFFER2_SIZE vBIT(0xFFFF,32,16)
-#define SET_BUFFER0_SIZE(val) vBIT(val,8,8)
-#define SET_BUFFER1_SIZE(val) vBIT(val,16,16)
-#define SET_BUFFER2_SIZE(val) vBIT(val,32,16)
-#endif
-
#define MASK_VLAN_TAG vBIT(0xFFFF,48,16)
#define SET_VLAN_TAG(val) vBIT(val,48,16)
#define SET_NUM_TAG(val) vBIT(val,16,32)
-#ifndef CONFIG_2BUFF_MODE
-#define RXD_GET_BUFFER0_SIZE(Control_2) (u64)((Control_2 & vBIT(0x3FFF,2,14)))
-#else
-#define RXD_GET_BUFFER0_SIZE(Control_2) (u8)((Control_2 & MASK_BUFFER0_SIZE) \
- >> 48)
-#define RXD_GET_BUFFER1_SIZE(Control_2) (u16)((Control_2 & MASK_BUFFER1_SIZE) \
- >> 32)
-#define RXD_GET_BUFFER2_SIZE(Control_2) (u16)((Control_2 & MASK_BUFFER2_SIZE) \
- >> 16)
+
+} RxD_t;
+/* Rx descriptor structure for 1 buffer mode */
+typedef struct _RxD1_t {
+ struct _RxD_t h;
+
+#define MASK_BUFFER0_SIZE_1 vBIT(0x3FFF,2,14)
+#define SET_BUFFER0_SIZE_1(val) vBIT(val,2,14)
+#define RXD_GET_BUFFER0_SIZE_1(_Control_2) \
+ (u16)((_Control_2 & MASK_BUFFER0_SIZE_1) >> 48)
+ u64 Buffer0_ptr;
+} RxD1_t;
+/* Rx descriptor structure for 3 or 2 buffer mode */
+
+typedef struct _RxD3_t {
+ struct _RxD_t h;
+
+#define MASK_BUFFER0_SIZE_3 vBIT(0xFF,2,14)
+#define MASK_BUFFER1_SIZE_3 vBIT(0xFFFF,16,16)
+#define MASK_BUFFER2_SIZE_3 vBIT(0xFFFF,32,16)
+#define SET_BUFFER0_SIZE_3(val) vBIT(val,8,8)
+#define SET_BUFFER1_SIZE_3(val) vBIT(val,16,16)
+#define SET_BUFFER2_SIZE_3(val) vBIT(val,32,16)
+#define RXD_GET_BUFFER0_SIZE_3(Control_2) \
+ (u8)((Control_2 & MASK_BUFFER0_SIZE_3) >> 48)
+#define RXD_GET_BUFFER1_SIZE_3(Control_2) \
+ (u16)((Control_2 & MASK_BUFFER1_SIZE_3) >> 32)
+#define RXD_GET_BUFFER2_SIZE_3(Control_2) \
+ (u16)((Control_2 & MASK_BUFFER2_SIZE_3) >> 16)
#define BUF0_LEN 40
#define BUF1_LEN 1
-#endif
u64 Buffer0_ptr;
-#ifdef CONFIG_2BUFF_MODE
u64 Buffer1_ptr;
u64 Buffer2_ptr;
-#endif
-} RxD_t;
+} RxD3_t;
+
/* Structure that represents the Rx descriptor block which contains
* 128 Rx descriptors.
*/
-#ifndef CONFIG_2BUFF_MODE
typedef struct _RxD_block {
-#define MAX_RXDS_PER_BLOCK 127
- RxD_t rxd[MAX_RXDS_PER_BLOCK];
+#define MAX_RXDS_PER_BLOCK_1 127
+ RxD1_t rxd[MAX_RXDS_PER_BLOCK_1];
u64 reserved_0;
#define END_OF_BLOCK 0xFEFFFFFFFFFFFFFFULL
@@ -492,18 +497,13 @@ typedef struct _RxD_block {
* the upper 32 bits should
* be 0 */
} RxD_block_t;
-#else
-typedef struct _RxD_block {
-#define MAX_RXDS_PER_BLOCK 85
- RxD_t rxd[MAX_RXDS_PER_BLOCK];
-#define END_OF_BLOCK 0xFEFFFFFFFFFFFFFFULL
- u64 reserved_1; /* 0xFEFFFFFFFFFFFFFF to mark last Rxd
- * in this blk */
- u64 pNext_RxD_Blk_physical; /* Phy ponter to next blk. */
-} RxD_block_t;
#define SIZE_OF_BLOCK 4096
+#define RXD_MODE_1 0
+#define RXD_MODE_3A 1
+#define RXD_MODE_3B 2
+
/* Structure to hold virtual addresses of Buf0 and Buf1 in
* 2buf mode. */
typedef struct bufAdd {
@@ -512,7 +512,6 @@ typedef struct bufAdd {
void *ba_0;
void *ba_1;
} buffAdd_t;
-#endif
/* Structure which stores all the MAC control parameters */
@@ -539,10 +538,17 @@ typedef struct {
typedef tx_curr_get_info_t tx_curr_put_info_t;
+
+typedef struct rxd_info {
+ void *virt_addr;
+ dma_addr_t dma_addr;
+}rxd_info_t;
+
/* Structure that holds the Phy and virt addresses of the Blocks */
typedef struct rx_block_info {
- RxD_t *block_virt_addr;
+ void *block_virt_addr;
dma_addr_t block_dma_addr;
+ rxd_info_t *rxds;
} rx_block_info_t;
/* pre declaration of the nic structure */
@@ -578,10 +584,8 @@ typedef struct ring_info {
int put_pos;
#endif
-#ifdef CONFIG_2BUFF_MODE
/* Buffer Address store. */
buffAdd_t **ba;
-#endif
nic_t *nic;
} ring_info_t;
@@ -647,8 +651,6 @@ typedef struct {
/* Default Tunable parameters of the NIC. */
#define DEFAULT_FIFO_LEN 4096
-#define SMALL_RXD_CNT 30 * (MAX_RXDS_PER_BLOCK+1)
-#define LARGE_RXD_CNT 100 * (MAX_RXDS_PER_BLOCK+1)
#define SMALL_BLK_CNT 30
#define LARGE_BLK_CNT 100
@@ -678,6 +680,7 @@ struct msix_info_st {
/* Structure representing one instance of the NIC */
struct s2io_nic {
+ int rxd_mode;
#ifdef CONFIG_S2IO_NAPI
/*
* Count of packets to be processed in a given iteration, it will be indicated
OpenPOWER on IntegriCloud