md: make merge_bvec_fn more robust in face of personality changes.
There is no locking around calls to merge_bvec_fn(), so it is possible that calls which coincide with a level (or personality) change could go wrong. So create a central dispatch point for these functions and use rcu_read_lock(). If the array is suspended, reject any merge that can be rejected. If not, we know it is safe to call the function. Signed-off-by: NeilBrown <neilb@suse.de>
Diffstat (limited to 'drivers/md/raid10.c')
-rw-r--r--drivers/md/raid10.c7
1 files changed, 3 insertions, 4 deletions
diff --git a/drivers/md/raid10.c b/drivers/md/raid10.c
index fb6b886..407c81a 100644
--- a/drivers/md/raid10.c
+++ b/drivers/md/raid10.c
@@ -674,7 +674,7 @@ static sector_t raid10_find_virt(struct r10conf *conf, sector_t sector, int dev)
/**
* raid10_mergeable_bvec -- tell bio layer if a two requests can be merged
- * @q: request queue
+ * @mddev: the md device
* @bvm: properties of new bio
* @biovec: the request that could be merged to it.
*
@@ -682,11 +682,10 @@ static sector_t raid10_find_virt(struct r10conf *conf, sector_t sector, int dev)
* This requires checking for end-of-chunk if near_copies != raid_disks,
* and for subordinate merge_bvec_fns if merge_check_needed.
*/
-static int raid10_mergeable_bvec(struct request_queue *q,
+static int raid10_mergeable_bvec(struct mddev *mddev,
struct bvec_merge_data *bvm,
struct bio_vec *biovec)
{
- struct mddev *mddev = q->queuedata;
struct r10conf *conf = mddev->private;
sector_t sector = bvm->bi_sector + get_start_sect(bvm->bi_bdev);
int max;
@@ -3756,7 +3755,6 @@ static int run(struct mddev *mddev)
stripe /= conf->geo.near_copies;
if (mddev->queue->backing_dev_info.ra_pages < 2 * stripe)
mddev->queue->backing_dev_info.ra_pages = 2 * stripe;
- blk_queue_merge_bvec(mddev->queue, raid10_mergeable_bvec);
}
if (md_integrity_register(mddev))
@@ -4717,6 +4715,7 @@ static struct md_personality raid10_personality =
.start_reshape = raid10_start_reshape,
.finish_reshape = raid10_finish_reshape,
.congested = raid10_congested,
+ .mergeable_bvec = raid10_mergeable_bvec,
};