summaryrefslogtreecommitdiffstats
path: root/drivers/infiniband/hw/ehca/ehca_irq.c
diff options
context:
space:
mode:
authorStephen Rothwell <sfr@canb.auug.org.au>2009-01-16 14:55:28 -0800
committerRoland Dreier <rolandd@cisco.com>2009-01-16 14:55:28 -0800
commit3750f60557b68776eb749859ad68af70d1a01ad0 (patch)
tree13b968eafa143fccc13dbdeb40105d6d6a42ca5e /drivers/infiniband/hw/ehca/ehca_irq.c
parente0b325d310a6b11f1538413fd557d2eb98f2fae5 (diff)
downloadop-kernel-dev-3750f60557b68776eb749859ad68af70d1a01ad0.zip
op-kernel-dev-3750f60557b68776eb749859ad68af70d1a01ad0.tar.gz
IB/ehca: Fix printk format warnings from u64 type change
Commit fe333321 ("powerpc: Change u64/s64 to a long long integer type") changed u64 from unsigned long to unsigned long long, which means that printk formats for printing u64 values should use "ll" instead of "l" to avoid warnings. Fix all the places affected by this in ehca. Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au> Signed-off-by: Roland Dreier <rolandd@cisco.com>
Diffstat (limited to 'drivers/infiniband/hw/ehca/ehca_irq.c')
-rw-r--r--drivers/infiniband/hw/ehca/ehca_irq.c18
1 files changed, 9 insertions, 9 deletions
diff --git a/drivers/infiniband/hw/ehca/ehca_irq.c b/drivers/infiniband/hw/ehca/ehca_irq.c
index 3128a50..99bcbd7 100644
--- a/drivers/infiniband/hw/ehca/ehca_irq.c
+++ b/drivers/infiniband/hw/ehca/ehca_irq.c
@@ -99,7 +99,7 @@ static void print_error_data(struct ehca_shca *shca, void *data,
return;
ehca_err(&shca->ib_device,
- "QP 0x%x (resource=%lx) has errors.",
+ "QP 0x%x (resource=%llx) has errors.",
qp->ib_qp.qp_num, resource);
break;
}
@@ -108,21 +108,21 @@ static void print_error_data(struct ehca_shca *shca, void *data,
struct ehca_cq *cq = (struct ehca_cq *)data;
ehca_err(&shca->ib_device,
- "CQ 0x%x (resource=%lx) has errors.",
+ "CQ 0x%x (resource=%llx) has errors.",
cq->cq_number, resource);
break;
}
default:
ehca_err(&shca->ib_device,
- "Unknown error type: %lx on %s.",
+ "Unknown error type: %llx on %s.",
type, shca->ib_device.name);
break;
}
- ehca_err(&shca->ib_device, "Error data is available: %lx.", resource);
+ ehca_err(&shca->ib_device, "Error data is available: %llx.", resource);
ehca_err(&shca->ib_device, "EHCA ----- error data begin "
"---------------------------------------------------");
- ehca_dmp(rblock, length, "resource=%lx", resource);
+ ehca_dmp(rblock, length, "resource=%llx", resource);
ehca_err(&shca->ib_device, "EHCA ----- error data end "
"----------------------------------------------------");
@@ -152,7 +152,7 @@ int ehca_error_data(struct ehca_shca *shca, void *data,
if (ret == H_R_STATE)
ehca_err(&shca->ib_device,
- "No error data is available: %lx.", resource);
+ "No error data is available: %llx.", resource);
else if (ret == H_SUCCESS) {
int length;
@@ -164,7 +164,7 @@ int ehca_error_data(struct ehca_shca *shca, void *data,
print_error_data(shca, data, rblock, length);
} else
ehca_err(&shca->ib_device,
- "Error data could not be fetched: %lx", resource);
+ "Error data could not be fetched: %llx", resource);
ehca_free_fw_ctrlblock(rblock);
@@ -514,7 +514,7 @@ static inline void process_eqe(struct ehca_shca *shca, struct ehca_eqe *eqe)
struct ehca_cq *cq;
eqe_value = eqe->entry;
- ehca_dbg(&shca->ib_device, "eqe_value=%lx", eqe_value);
+ ehca_dbg(&shca->ib_device, "eqe_value=%llx", eqe_value);
if (EHCA_BMASK_GET(EQE_COMPLETION_EVENT, eqe_value)) {
ehca_dbg(&shca->ib_device, "Got completion event");
token = EHCA_BMASK_GET(EQE_CQ_TOKEN, eqe_value);
@@ -603,7 +603,7 @@ void ehca_process_eq(struct ehca_shca *shca, int is_irq)
ret = hipz_h_eoi(eq->ist);
if (ret != H_SUCCESS)
ehca_err(&shca->ib_device,
- "bad return code EOI -rc = %ld\n", ret);
+ "bad return code EOI -rc = %lld\n", ret);
ehca_dbg(&shca->ib_device, "deadman found %x eqe", eqe_cnt);
}
if (unlikely(eqe_cnt == EHCA_EQE_CACHE_SIZE))
OpenPOWER on IntegriCloud