summaryrefslogtreecommitdiffstats
path: root/drivers/i2c/busses
diff options
context:
space:
mode:
authorMika Westerberg <mika.westerberg@linux.intel.com>2017-02-01 19:20:59 +0300
committerWolfram Sang <wsa@the-dreams.de>2017-02-09 17:39:16 +0100
commit9827f9eb79c56424eac6409197a290601cf78eee (patch)
tree20a3aa88d84a22cb858667521f37bde7c3673391 /drivers/i2c/busses
parente278d64190c2dafc49f63857dd1e0e7689a15bfa (diff)
downloadop-kernel-dev-9827f9eb79c56424eac6409197a290601cf78eee.zip
op-kernel-dev-9827f9eb79c56424eac6409197a290601cf78eee.tar.gz
i2c: i801: Add support for Intel Gemini Lake
Intel Gemini Lake has the same SMBus host controller than Intel Broxton. Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com> Signed-off-by: Jean Delvare <jdelvare@suse.de> Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
Diffstat (limited to 'drivers/i2c/busses')
-rw-r--r--drivers/i2c/busses/Kconfig1
-rw-r--r--drivers/i2c/busses/i2c-i801.c3
2 files changed, 4 insertions, 0 deletions
diff --git a/drivers/i2c/busses/Kconfig b/drivers/i2c/busses/Kconfig
index 27192084..c64221d 100644
--- a/drivers/i2c/busses/Kconfig
+++ b/drivers/i2c/busses/Kconfig
@@ -128,6 +128,7 @@ config I2C_I801
DNV (SOC)
Broxton (SOC)
Lewisburg (PCH)
+ Gemini Lake (SOC)
This driver can also be built as a module. If so, the module
will be called i2c-i801.
diff --git a/drivers/i2c/busses/i2c-i801.c b/drivers/i2c/busses/i2c-i801.c
index e242db4..6484fa6 100644
--- a/drivers/i2c/busses/i2c-i801.c
+++ b/drivers/i2c/busses/i2c-i801.c
@@ -65,6 +65,7 @@
* Lewisburg (PCH) 0xa1a3 32 hard yes yes yes
* Lewisburg Supersku (PCH) 0xa223 32 hard yes yes yes
* Kaby Lake PCH-H (PCH) 0xa2a3 32 hard yes yes yes
+ * Gemini Lake (SOC) 0x31d4 32 hard yes yes yes
*
* Features supported by this driver:
* Software PEC no
@@ -213,6 +214,7 @@
#define PCI_DEVICE_ID_INTEL_BRASWELL_SMBUS 0x2292
#define PCI_DEVICE_ID_INTEL_DH89XXCC_SMBUS 0x2330
#define PCI_DEVICE_ID_INTEL_COLETOCREEK_SMBUS 0x23b0
+#define PCI_DEVICE_ID_INTEL_GEMINILAKE_SMBUS 0x31d4
#define PCI_DEVICE_ID_INTEL_5_3400_SERIES_SMBUS 0x3b30
#define PCI_DEVICE_ID_INTEL_BROXTON_SMBUS 0x5ad4
#define PCI_DEVICE_ID_INTEL_LYNXPOINT_SMBUS 0x8c22
@@ -1012,6 +1014,7 @@ static const struct pci_device_id i801_ids[] = {
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_WELLSBURG_SMBUS_MS1) },
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_WELLSBURG_SMBUS_MS2) },
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_COLETOCREEK_SMBUS) },
+ { PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_GEMINILAKE_SMBUS) },
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_WILDCATPOINT_SMBUS) },
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_WILDCATPOINT_LP_SMBUS) },
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_BAYTRAIL_SMBUS) },
OpenPOWER on IntegriCloud