authorJean Delvare <khali@linux-fr.org>2008-10-17 17:51:09 +0200
committerJean Delvare <khali@mahadeva.delvare>2008-10-17 17:51:09 +0200
commit6388a388ffb720f40fc8046c261252ea2be9c12f (patch)
tree1b5bcc83cd1fb6cac9fd222914545a43e1d7b3d4 /drivers/hwmon/lm90.c
parent2e532d68a2b3e2aa6b19731501222069735c741c (diff)
downloadop-kernel-dev-6388a388ffb720f40fc8046c261252ea2be9c12f.zip
op-kernel-dev-6388a388ffb720f40fc8046c261252ea2be9c12f.tar.gz
hwmon: (lm90) Move 16-bit value read to a separate function
Move the code which aggregates two 8-bit register values into a 16-bit value to a separate function. We'll need to do it a second time soon and I don't want to duplicate the code. Signed-off-by: Jean Delvare <khali@linux-fr.org> Acked-by: Martyn Welch <martyn.welch@gefanuc.com>
Diffstat (limited to 'drivers/hwmon/lm90.c')
-rw-r--r--drivers/hwmon/lm90.c72
1 files changed, 43 insertions, 29 deletions
diff --git a/drivers/hwmon/lm90.c b/drivers/hwmon/lm90.c
index c24fe36..73a1c62 100644
--- a/drivers/hwmon/lm90.c
+++ b/drivers/hwmon/lm90.c
@@ -1,7 +1,7 @@
/*
* lm90.c - Part of lm_sensors, Linux kernel modules for hardware
* monitoring
- * Copyright (C) 2003-2006 Jean Delvare <khali@linux-fr.org>
+ * Copyright (C) 2003-2008 Jean Delvare <khali@linux-fr.org>
*
* Based on the lm83 driver. The LM90 is a sensor chip made by National
* Semiconductor. It reports up to two temperatures (its own plus up to
@@ -736,6 +736,38 @@ static int lm90_remove(struct i2c_client *client)
return 0;
}
+static int lm90_read16(struct i2c_client *client, u8 regh, u8 regl, u16 *value)
+{
+ int err;
+ u8 oldh, newh, l;
+
+ /*
+ * There is a trick here. We have to read two registers to have the
+ * sensor temperature, but we have to beware a conversion could occur
+ * inbetween the readings. The datasheet says we should either use
+ * the one-shot conversion register, which we don't want to do
+ * (disables hardware monitoring) or monitor the busy bit, which is
+ * impossible (we can't read the values and monitor that bit at the
+ * exact same time). So the solution used here is to read the high
+ * byte once, then the low byte, then the high byte again. If the new
+ * high byte matches the old one, then we have a valid reading. Else
+ * we have to read the low byte again, and now we believe we have a
+ * correct reading.
+ */
+ if ((err = lm90_read_reg(client, regh, &oldh))
+ || (err = lm90_read_reg(client, regl, &l))
+ || (err = lm90_read_reg(client, regh, &newh)))
+ return err;
+ if (oldh != newh) {
+ err = lm90_read_reg(client, regl, &l);
+ if (err)
+ return err;
+ }
+ *value = (newh << 8) | l;
+
+ return 0;
+}
+
static struct lm90_data *lm90_update_device(struct device *dev)
{
struct i2c_client *client = to_i2c_client(dev);
@@ -744,7 +776,7 @@ static struct lm90_data *lm90_update_device(struct device *dev)
mutex_lock(&data->update_lock);
if (time_after(jiffies, data->last_updated + HZ * 2) || !data->valid) {
- u8 oldh, newh, l;
+ u8 h, l;
dev_dbg(&client->dev, "Updating lm90 data.\n");
lm90_read_reg(client, LM90_REG_R_LOCAL_TEMP, &data->temp8[0]);
@@ -754,39 +786,21 @@ static struct lm90_data *lm90_update_device(struct device *dev)
lm90_read_reg(client, LM90_REG_R_REMOTE_CRIT, &data->temp8[4]);
lm90_read_reg(client, LM90_REG_R_TCRIT_HYST, &data->temp_hyst);
- /*
- * There is a trick here. We have to read two registers to
- * have the remote sensor temperature, but we have to beware
- * a conversion could occur inbetween the readings. The
- * datasheet says we should either use the one-shot
- * conversion register, which we don't want to do (disables
- * hardware monitoring) or monitor the busy bit, which is
- * impossible (we can't read the values and monitor that bit
- * at the exact same time). So the solution used here is to
- * read the high byte once, then the low byte, then the high
- * byte again. If the new high byte matches the old one,
- * then we have a valid reading. Else we have to read the low
- * byte again, and now we believe we have a correct reading.
- */
- if (lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPH, &oldh) == 0
- && lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPL, &l) == 0
- && lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPH, &newh) == 0
- && (newh == oldh
- || lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPL, &l) == 0))
- data->temp11[0] = (newh << 8) | l;
-
- if (lm90_read_reg(client, LM90_REG_R_REMOTE_LOWH, &newh) == 0
+ lm90_read16(client, LM90_REG_R_REMOTE_TEMPH,
+ LM90_REG_R_REMOTE_TEMPL, &data->temp11[0]);
+
+ if (lm90_read_reg(client, LM90_REG_R_REMOTE_LOWH, &h) == 0
&& lm90_read_reg(client, LM90_REG_R_REMOTE_LOWL, &l) == 0)
- data->temp11[1] = (newh << 8) | l;
- if (lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHH, &newh) == 0
+ data->temp11[1] = (h << 8) | l;
+ if (lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHH, &h) == 0
&& lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHL, &l) == 0)
- data->temp11[2] = (newh << 8) | l;
+ data->temp11[2] = (h << 8) | l;
if (data->kind != max6657) {
if (lm90_read_reg(client, LM90_REG_R_REMOTE_OFFSH,
- &newh) == 0
+ &h) == 0
&& lm90_read_reg(client, LM90_REG_R_REMOTE_OFFSL,
&l) == 0)
- data->temp11[3] = (newh << 8) | l;
+ data->temp11[3] = (h << 8) | l;
}
lm90_read_reg(client, LM90_REG_R_STATUS, &data->alarms);
OpenPOWER on IntegriCloud