drm/i915: Cleanup test data during long/short hotplug
Automated test data that is updated when a test is requested is not cleared till next automated test request is recevied which can cause various problems. This patch fixes this by clearing this during the next short pulse and on hot unplug. For example, when TEST_LINK_TRAINING is requested it is updated to appropriate variable inside intel_dp_handle_test_request but is also cleared only inside the same function. if the next short pulse does not have the AUTOMATED_TEST_REQUEST bits set the variable will not be cleared resulting in carrying incorrect test status in local variables. v2: Added comments and moved nack and defer variables before set_edid (Sonika) Signed-off-by: Sivakumar Thulasimani <sivakumar.thulasimani@intel.com> Signed-off-by: Shubhangi Shrivastava <shubhangi.shrivastava@intel.com> Reviewed-by: Sonika Jindal <sonika.jindal@intel.com Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch>
Diffstat (limited to 'drivers/gpu/drm/i915/intel_dp.c')
-rw-r--r--drivers/gpu/drm/i915/intel_dp.c30
1 files changed, 22 insertions, 8 deletions
diff --git a/drivers/gpu/drm/i915/intel_dp.c b/drivers/gpu/drm/i915/intel_dp.c
index 8071247..92504fc 100644
--- a/drivers/gpu/drm/i915/intel_dp.c
+++ b/drivers/gpu/drm/i915/intel_dp.c
@@ -4163,13 +4163,6 @@ static void intel_dp_handle_test_request(struct intel_dp *intel_dp)
uint8_t rxdata = 0;
int status = 0;
- intel_dp->compliance_test_active = 0;
- intel_dp->compliance_test_type = 0;
- intel_dp->compliance_test_data = 0;
-
- intel_dp->aux.i2c_nack_count = 0;
- intel_dp->aux.i2c_defer_count = 0;
-
status = drm_dp_dpcd_read(&intel_dp->aux, DP_TEST_REQUEST, &rxdata, 1);
if (status <= 0) {
DRM_DEBUG_KMS("Could not read test request from sink\n");
@@ -4285,6 +4278,14 @@ intel_dp_check_link_status(struct intel_dp *intel_dp)
WARN_ON(!drm_modeset_is_locked(&dev->mode_config.connection_mutex));
+ /*
+ * Clearing compliance test variables to allow capturing
+ * of values for next automated test request.
+ */
+ intel_dp->compliance_test_active = 0;
+ intel_dp->compliance_test_type = 0;
+ intel_dp->compliance_test_data = 0;
+
if (!intel_encoder->base.crtc)
return;
@@ -4663,8 +4664,13 @@ intel_dp_detect(struct drm_connector *connector, bool force)
status = ironlake_dp_detect(intel_dp);
else
status = g4x_dp_detect(intel_dp);
- if (status != connector_status_connected)
+ if (status != connector_status_connected) {
+ intel_dp->compliance_test_active = 0;
+ intel_dp->compliance_test_type = 0;
+ intel_dp->compliance_test_data = 0;
+
goto out;
+ }
intel_dp_probe_oui(intel_dp);
@@ -4678,6 +4684,14 @@ intel_dp_detect(struct drm_connector *connector, bool force)
goto out;
}
+ /*
+ * Clearing NACK and defer counts to get their exact values
+ * while reading EDID which are required by Compliance tests
+ * 4.2.2.4 and 4.2.2.5
+ */
+ intel_dp->aux.i2c_nack_count = 0;
+ intel_dp->aux.i2c_defer_count = 0;
+
intel_dp_set_edid(intel_dp);
if (intel_encoder->type != INTEL_OUTPUT_EDP)
OpenPOWER on IntegriCloud