summaryrefslogtreecommitdiffstats
path: root/drivers/acpi/processor_thermal.c
diff options
context:
space:
mode:
authorThomas Renninger <trenn@suse.de>2004-09-16 11:07:00 -0400
committerLen Brown <len.brown@intel.com>2005-11-30 22:51:04 -0500
commit1cbf4c563c0eaaf11c552a88b374e213181c6ddd (patch)
tree6ec08fedd46526c3dbed911026e1581c82d50531 /drivers/acpi/processor_thermal.c
parentd2149b542382bfc206cb28485108f6470c979566 (diff)
downloadop-kernel-dev-1cbf4c563c0eaaf11c552a88b374e213181c6ddd.zip
op-kernel-dev-1cbf4c563c0eaaf11c552a88b374e213181c6ddd.tar.gz
[ACPI] Allow return to active cooling mode once passive mode is entered
http://bugzilla.kernel.org/show_bug.cgi?id=3410 https://bugzilla.novell.com/show_bug.cgi?id=131543 Signed-off-by: Thomas Renninger <trenn@suse.de> Signed-off-by: Konstantin Karasyov <konstantin.a.karasyov@intel.com> Signed-off-by: Alexey Starikovskiy <alexey.y.starikovskiy@intel.com> Signed-off-by: Yu Luming <luming.yu@gmail.com> Signed-off-by: Andrew Morton <akpm@osdl.org>
Diffstat (limited to 'drivers/acpi/processor_thermal.c')
-rw-r--r--drivers/acpi/processor_thermal.c38
1 files changed, 23 insertions, 15 deletions
diff --git a/drivers/acpi/processor_thermal.c b/drivers/acpi/processor_thermal.c
index 37528c3..f375840 100644
--- a/drivers/acpi/processor_thermal.c
+++ b/drivers/acpi/processor_thermal.c
@@ -101,9 +101,7 @@ static unsigned int acpi_thermal_cpufreq_is_init = 0;
static int cpu_has_cpufreq(unsigned int cpu)
{
struct cpufreq_policy policy;
- if (!acpi_thermal_cpufreq_is_init)
- return -ENODEV;
- if (!cpufreq_get_policy(&policy, cpu))
+ if (!acpi_thermal_cpufreq_is_init || cpufreq_get_policy(&policy, cpu))
return -ENODEV;
return 0;
}
@@ -127,13 +125,13 @@ static int acpi_thermal_cpufreq_decrease(unsigned int cpu)
if (!cpu_has_cpufreq(cpu))
return -ENODEV;
- if (cpufreq_thermal_reduction_pctg[cpu] >= 20) {
+ if (cpufreq_thermal_reduction_pctg[cpu] > 20)
cpufreq_thermal_reduction_pctg[cpu] -= 20;
- cpufreq_update_policy(cpu);
- return 0;
- }
-
- return -ERANGE;
+ else
+ cpufreq_thermal_reduction_pctg[cpu] = 0;
+ cpufreq_update_policy(cpu);
+ /* We reached max freq again and can leave passive mode */
+ return !cpufreq_thermal_reduction_pctg[cpu];
}
static int acpi_thermal_cpufreq_notifier(struct notifier_block *nb,
@@ -200,7 +198,7 @@ int acpi_processor_set_thermal_limit(acpi_handle handle, int type)
int result = 0;
struct acpi_processor *pr = NULL;
struct acpi_device *device = NULL;
- int tx = 0;
+ int tx = 0, max_tx_px = 0;
ACPI_FUNCTION_TRACE("acpi_processor_set_thermal_limit");
@@ -259,19 +257,27 @@ int acpi_processor_set_thermal_limit(acpi_handle handle, int type)
/* if going down: T-states first, P-states later */
if (pr->flags.throttling) {
- if (tx == 0)
+ if (tx == 0) {
+ max_tx_px = 1;
ACPI_DEBUG_PRINT((ACPI_DB_INFO,
"At minimum throttling state\n"));
- else {
+ } else {
tx--;
goto end;
}
}
result = acpi_thermal_cpufreq_decrease(pr->id);
- if (result == -ERANGE)
+ if (result) {
+ /*
+ * We only could get -ERANGE, 1 or 0.
+ * In the first two cases we reached max freq again.
+ */
ACPI_DEBUG_PRINT((ACPI_DB_INFO,
"At minimum performance state\n"));
+ max_tx_px = 1;
+ } else
+ max_tx_px = 0;
break;
}
@@ -290,8 +296,10 @@ int acpi_processor_set_thermal_limit(acpi_handle handle, int type)
pr->limit.thermal.px, pr->limit.thermal.tx));
} else
result = 0;
-
- return_VALUE(result);
+ if (max_tx_px)
+ return_VALUE(1);
+ else
+ return_VALUE(result);
}
int acpi_processor_get_limit_info(struct acpi_processor *pr)
OpenPOWER on IntegriCloud