summaryrefslogtreecommitdiffstats
path: root/block/cfq-iosched.c
diff options
context:
space:
mode:
authorChristoph Hellwig <hch@lst.de>2010-08-07 18:20:39 +0200
committerJens Axboe <jaxboe@fusionio.com>2010-08-07 18:20:39 +0200
commit7b6d91daee5cac6402186ff224c3af39d79f4a0e (patch)
treeb1518cf0b6c301178e0a320f80610cd5b3aa7625 /block/cfq-iosched.c
parent33659ebbae262228eef4e0fe990f393d1f0ed941 (diff)
downloadop-kernel-dev-7b6d91daee5cac6402186ff224c3af39d79f4a0e.zip
op-kernel-dev-7b6d91daee5cac6402186ff224c3af39d79f4a0e.tar.gz
block: unify flags for struct bio and struct request
Remove the current bio flags and reuse the request flags for the bio, too. This allows to more easily trace the type of I/O from the filesystem down to the block driver. There were two flags in the bio that were missing in the requests: BIO_RW_UNPLUG and BIO_RW_AHEAD. Also I've renamed two request flags that had a superflous RW in them. Note that the flags are in bio.h despite having the REQ_ name - as blkdev.h includes bio.h that is the only way to go for now. Signed-off-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Jens Axboe <jaxboe@fusionio.com>
Diffstat (limited to 'block/cfq-iosched.c')
-rw-r--r--block/cfq-iosched.c14
1 files changed, 7 insertions, 7 deletions
diff --git a/block/cfq-iosched.c b/block/cfq-iosched.c
index d4edeb8..eb4086f 100644
--- a/block/cfq-iosched.c
+++ b/block/cfq-iosched.c
@@ -458,7 +458,7 @@ static inline struct cfq_data *cic_to_cfqd(struct cfq_io_context *cic)
*/
static inline bool cfq_bio_sync(struct bio *bio)
{
- return bio_data_dir(bio) == READ || bio_rw_flagged(bio, BIO_RW_SYNCIO);
+ return bio_data_dir(bio) == READ || (bio->bi_rw & REQ_SYNC);
}
/*
@@ -646,10 +646,10 @@ cfq_choose_req(struct cfq_data *cfqd, struct request *rq1, struct request *rq2,
return rq1;
else if (rq_is_sync(rq2) && !rq_is_sync(rq1))
return rq2;
- if ((rq1->cmd_flags & REQ_RW_META) && !(rq2->cmd_flags & REQ_RW_META))
+ if ((rq1->cmd_flags & REQ_META) && !(rq2->cmd_flags & REQ_META))
return rq1;
- else if ((rq2->cmd_flags & REQ_RW_META) &&
- !(rq1->cmd_flags & REQ_RW_META))
+ else if ((rq2->cmd_flags & REQ_META) &&
+ !(rq1->cmd_flags & REQ_META))
return rq2;
s1 = blk_rq_pos(rq1);
@@ -1485,7 +1485,7 @@ static void cfq_remove_request(struct request *rq)
cfqq->cfqd->rq_queued--;
cfq_blkiocg_update_io_remove_stats(&(RQ_CFQG(rq))->blkg,
rq_data_dir(rq), rq_is_sync(rq));
- if (rq->cmd_flags & REQ_RW_META) {
+ if (rq->cmd_flags & REQ_META) {
WARN_ON(!cfqq->meta_pending);
cfqq->meta_pending--;
}
@@ -3177,7 +3177,7 @@ cfq_should_preempt(struct cfq_data *cfqd, struct cfq_queue *new_cfqq,
* So both queues are sync. Let the new request get disk time if
* it's a metadata request and the current queue is doing regular IO.
*/
- if ((rq->cmd_flags & REQ_RW_META) && !cfqq->meta_pending)
+ if ((rq->cmd_flags & REQ_META) && !cfqq->meta_pending)
return true;
/*
@@ -3231,7 +3231,7 @@ cfq_rq_enqueued(struct cfq_data *cfqd, struct cfq_queue *cfqq,
struct cfq_io_context *cic = RQ_CIC(rq);
cfqd->rq_queued++;
- if (rq->cmd_flags & REQ_RW_META)
+ if (rq->cmd_flags & REQ_META)
cfqq->meta_pending++;
cfq_update_io_thinktime(cfqd, cic);
OpenPOWER on IntegriCloud