summaryrefslogtreecommitdiffstats
path: root/arch
diff options
context:
space:
mode:
authorGavin Shan <shangw@linux.vnet.ibm.com>2013-06-05 14:25:50 +0000
committerBenjamin Herrenschmidt <benh@kernel.crashing.org>2013-06-10 08:36:16 +1000
commitb8b3de224f194005ad87ede6fd022fcc2bef3b1a (patch)
tree9b86b3580c0e615700ecf84653f0364be8164154 /arch
parentc5df457ffe6db7569de9fb856de490b5317c97b4 (diff)
downloadop-kernel-dev-b8b3de224f194005ad87ede6fd022fcc2bef3b1a.zip
op-kernel-dev-b8b3de224f194005ad87ede6fd022fcc2bef3b1a.tar.gz
powerpc/eeh: Don't check RTAS token to get PE addr
RTAS token "ibm,get-config-addr-info" or ibm,get-config-addr-info2" are used to retrieve the PE address according to PCI address, which made up of domain/bus/slot/function. If we don't have those 2 tokens, the domain/bus/slot/function would be used as the address for EEH RTAS operations. Some older f/w might not have those 2 tokens and that blocks the EEH functionality to be initialized. It was introduced by commit e2af155c ("powerpc/eeh: pseries platform EEH initialization"). The patch skips the check on those 2 tokens so we can bring up EEH functionality successfully. And domain/bus/slot/function will be used as address for EEH RTAS operations. Cc: <stable@vger.kernel.org> # v3.4+ Reported-by: Robert Knight <knight@princeton.edu> Signed-off-by: Gavin Shan <shangw@linux.vnet.ibm.com> Tested-by: Robert Knight <knight@princeton.edu> Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
Diffstat (limited to 'arch')
-rw-r--r--arch/powerpc/platforms/pseries/eeh_pseries.c12
1 files changed, 5 insertions, 7 deletions
diff --git a/arch/powerpc/platforms/pseries/eeh_pseries.c b/arch/powerpc/platforms/pseries/eeh_pseries.c
index 19506f9..b456b15 100644
--- a/arch/powerpc/platforms/pseries/eeh_pseries.c
+++ b/arch/powerpc/platforms/pseries/eeh_pseries.c
@@ -83,7 +83,11 @@ static int pseries_eeh_init(void)
ibm_configure_pe = rtas_token("ibm,configure-pe");
ibm_configure_bridge = rtas_token("ibm,configure-bridge");
- /* necessary sanity check */
+ /*
+ * Necessary sanity check. We needn't check "get-config-addr-info"
+ * and its variant since the old firmware probably support address
+ * of domain/bus/slot/function for EEH RTAS operations.
+ */
if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE) {
pr_warning("%s: RTAS service <ibm,set-eeh-option> invalid\n",
__func__);
@@ -102,12 +106,6 @@ static int pseries_eeh_init(void)
pr_warning("%s: RTAS service <ibm,slot-error-detail> invalid\n",
__func__);
return -EINVAL;
- } else if (ibm_get_config_addr_info2 == RTAS_UNKNOWN_SERVICE &&
- ibm_get_config_addr_info == RTAS_UNKNOWN_SERVICE) {
- pr_warning("%s: RTAS service <ibm,get-config-addr-info2> and "
- "<ibm,get-config-addr-info> invalid\n",
- __func__);
- return -EINVAL;
} else if (ibm_configure_pe == RTAS_UNKNOWN_SERVICE &&
ibm_configure_bridge == RTAS_UNKNOWN_SERVICE) {
pr_warning("%s: RTAS service <ibm,configure-pe> and "
OpenPOWER on IntegriCloud