summaryrefslogtreecommitdiffstats
path: root/arch/x86/ia32
diff options
context:
space:
mode:
authorH. Peter Anvin <hpa@zytor.com>2012-03-05 13:40:24 -0800
committerH. Peter Anvin <hpa@zytor.com>2012-03-05 15:35:18 -0800
commite7084fd52ed71249ab2ce7a7d89d601c9d1f904c (patch)
tree354bdaa09b665f4e6d01ffdab2a26f8ceca9d630 /arch/x86/ia32
parenta628b684d27d22631d1819890f13047ae9075241 (diff)
downloadop-kernel-dev-e7084fd52ed71249ab2ce7a7d89d601c9d1f904c.zip
op-kernel-dev-e7084fd52ed71249ab2ce7a7d89d601c9d1f904c.tar.gz
x32: Switch to a 64-bit clock_t
clock_t is used mainly to give the number of jiffies a certain process has burned. It is entirely feasible for a long-running process to consume more than 2^32 jiffies especially in a multiprocess system. As such, switch to a 64-bit clock_t for x32, just as we already switched to a 64-bit time_t. clock_t is only used in a handful of places, and as such it is really not a very significant change. The one that has the biggest impact is in struct siginfo, but since the *size* of struct siginfo doesn't change (it is padded to the hilt) it is fairly easy to make this a localized change. This also gets rid of sys_x32_times, however since this is a pretty late change don't compactify the system call numbers; we can reuse system call slot 521 next time we need an x32 system call. Reported-by: Gregory M. Lueck <gregory.m.lueck@intel.com> Signed-off-by: H. Peter Anvin <hpa@zytor.com> Cc: H. J. Lu <hjl.tools@gmail.com> Link: http://lkml.kernel.org/r/1329696488-16970-1-git-send-email-hpa@zytor.com
Diffstat (limited to 'arch/x86/ia32')
-rw-r--r--arch/x86/ia32/ia32_signal.c10
1 files changed, 8 insertions, 2 deletions
diff --git a/arch/x86/ia32/ia32_signal.c b/arch/x86/ia32/ia32_signal.c
index 25d80f3..bc09ed2 100644
--- a/arch/x86/ia32/ia32_signal.c
+++ b/arch/x86/ia32/ia32_signal.c
@@ -37,6 +37,7 @@
int copy_siginfo_to_user32(compat_siginfo_t __user *to, siginfo_t *from)
{
int err = 0;
+ bool ia32 = !is_ia32_task();
if (!access_ok(VERIFY_WRITE, to, sizeof(compat_siginfo_t)))
return -EFAULT;
@@ -66,8 +67,13 @@ int copy_siginfo_to_user32(compat_siginfo_t __user *to, siginfo_t *from)
case __SI_FAULT >> 16:
break;
case __SI_CHLD >> 16:
- put_user_ex(from->si_utime, &to->si_utime);
- put_user_ex(from->si_stime, &to->si_stime);
+ if (ia32) {
+ put_user_ex(from->si_utime, &to->si_utime);
+ put_user_ex(from->si_stime, &to->si_stime);
+ } else {
+ put_user_ex(from->si_utime, &to->_sifields._sigchld_x32._utime);
+ put_user_ex(from->si_stime, &to->_sifields._sigchld_x32._stime);
+ }
put_user_ex(from->si_status, &to->si_status);
/* FALL THROUGH */
default:
OpenPOWER on IntegriCloud