diff options
author | Linus Torvalds <torvalds@g5.osdl.org> | 2006-09-27 14:41:24 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@g5.osdl.org> | 2006-09-27 14:41:24 -0700 |
commit | a77c64c1a641950626181b4857abb701d8f38ccc (patch) | |
tree | 9bfd2a99cc969b3d863d583b9ef18114a4fc4793 /Documentation | |
parent | ac7f6b5e44cb0982b98c31fa33298ba73fb5dcfc (diff) | |
parent | 0ba8821b12231386c8c1d506c682061f7225ae49 (diff) | |
download | op-kernel-dev-a77c64c1a641950626181b4857abb701d8f38ccc.zip op-kernel-dev-a77c64c1a641950626181b4857abb701d8f38ccc.tar.gz |
Merge branch 'upstream-linus' of master.kernel.org:/pub/scm/linux/kernel/git/jgarzik/netdev-2.6
* 'upstream-linus' of master.kernel.org:/pub/scm/linux/kernel/git/jgarzik/netdev-2.6: (48 commits)
[PATCH] bonding: update version number
[PATCH] git-netdev-all: pc300_tty build fix
[PATCH] Make PC300 WAN driver compile again
[PATCH] Modularize generic HDLC
[PATCH] more s2io __iomem annotations
[PATCH] restore __iomem annotations in e1000
[PATCH] 64bit bugs in s2io
[PATCH] bonding: Fix primary selection error at enslavement time
[PATCH] bonding: Don't mangle LACPDUs
[PATCH] bonding: Validate probe replies in ARP monitor
[PATCH] bonding: Don't release slaves when master is admin down
[PATCH] bonding: Add priv_flag to avoid event mishandling
[PATCH] bonding: Handle large hard_header_len
[PATCH] bonding: Remove unneeded NULL test
[PATCH] bonding: Format fix in seq_printf call
[PATCH] bonding: Convert delay value from s16 to int
[PATCH] bonding: Allow bonding to enslave a 10 Gig adapter
Delete unused drivers/net/gt64240eth.h
[PATCH] skge: fiber support
[PATCH] fix possible NULL ptr deref in forcedeth
...
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/networking/bonding.txt | 59 |
1 files changed, 59 insertions, 0 deletions
diff --git a/Documentation/networking/bonding.txt b/Documentation/networking/bonding.txt index afac780..dc942ea 100644 --- a/Documentation/networking/bonding.txt +++ b/Documentation/networking/bonding.txt @@ -192,6 +192,17 @@ or, for backwards compatibility, the option value. E.g., arp_interval Specifies the ARP link monitoring frequency in milliseconds. + + The ARP monitor works by periodically checking the slave + devices to determine whether they have sent or received + traffic recently (the precise criteria depends upon the + bonding mode, and the state of the slave). Regular traffic is + generated via ARP probes issued for the addresses specified by + the arp_ip_target option. + + This behavior can be modified by the arp_validate option, + below. + If ARP monitoring is used in an etherchannel compatible mode (modes 0 and 2), the switch should be configured in a mode that evenly distributes packets across all links. If the @@ -213,6 +224,54 @@ arp_ip_target maximum number of targets that can be specified is 16. The default value is no IP addresses. +arp_validate + + Specifies whether or not ARP probes and replies should be + validated in the active-backup mode. This causes the ARP + monitor to examine the incoming ARP requests and replies, and + only consider a slave to be up if it is receiving the + appropriate ARP traffic. + + Possible values are: + + none or 0 + + No validation is performed. This is the default. + + active or 1 + + Validation is performed only for the active slave. + + backup or 2 + + Validation is performed only for backup slaves. + + all or 3 + + Validation is performed for all slaves. + + For the active slave, the validation checks ARP replies to + confirm that they were generated by an arp_ip_target. Since + backup slaves do not typically receive these replies, the + validation performed for backup slaves is on the ARP request + sent out via the active slave. It is possible that some + switch or network configurations may result in situations + wherein the backup slaves do not receive the ARP requests; in + such a situation, validation of backup slaves must be + disabled. + + This option is useful in network configurations in which + multiple bonding hosts are concurrently issuing ARPs to one or + more targets beyond a common switch. Should the link between + the switch and target fail (but not the switch itself), the + probe traffic generated by the multiple bonding instances will + fool the standard ARP monitor into considering the links as + still up. Use of the arp_validate option can resolve this, as + the ARP monitor will only consider ARP requests and replies + associated with its own instance of bonding. + + This option was added in bonding version 3.1.0. + downdelay Specifies the time, in milliseconds, to wait before disabling |