Documentation: DT: Add bmi160 imu binding
This adds documentation for Bosch BMI160 Inertial Measurement Unit device-tree bindings. Signed-off-by: Marcin Niestroj <m.niestroj@grinn-global.com> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/devicetree/bindings/iio/imu/bmi160.txt36
1 files changed, 36 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/iio/imu/bmi160.txt b/Documentation/devicetree/bindings/iio/imu/bmi160.txt
new file mode 100644
index 0000000..ae0112c
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/imu/bmi160.txt
@@ -0,0 +1,36 @@
+Bosch BMI160 - Inertial Measurement Unit with Accelerometer, Gyroscope
+and externally connectable Magnetometer
+
+https://www.bosch-sensortec.com/bst/products/all_products/bmi160
+
+Required properties:
+ - compatible : should be "bosch,bmi160"
+ - reg : the I2C address or SPI chip select number of the sensor
+ - spi-max-frequency : set maximum clock frequency (only for SPI)
+
+Optional properties:
+ - interrupt-parent : should be the phandle of the interrupt controller
+ - interrupts : interrupt mapping for IRQ, must be IRQ_TYPE_LEVEL_LOW
+ - interrupt-names : set to "INT1" if INT1 pin should be used as interrupt
+ input, set to "INT2" if INT2 pin should be used instead
+
+Examples:
+
+bmi160@68 {
+ compatible = "bosch,bmi160";
+ reg = <0x68>;
+
+ interrupt-parent = <&gpio4>;
+ interrupts = <12 IRQ_TYPE_LEVEL_LOW>;
+ interrupt-names = "INT1";
+};
+
+bmi160@0 {
+ compatible = "bosch,bmi160";
+ reg = <0>;
+ spi-max-frequency = <10000000>;
+
+ interrupt-parent = <&gpio2>;
+ interrupts = <12 IRQ_TYPE_LEVEL_LOW>;
+ interrupt-names = "INT2";
+};