summaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
authorDaniel Jeong <gshark.jeong@gmail.com>2014-03-03 06:52:09 -0300
committerMauro Carvalho Chehab <m.chehab@samsung.com>2014-03-11 09:57:33 -0300
commit00ae54a728e3ab8c08ab4c3e9f6a5beef9b4ca5a (patch)
tree623a80ad20d599610a9246d09837a16db5816008 /Documentation
parent341ef565f8287695709266e7533995ffcdcc7a38 (diff)
downloadop-kernel-dev-00ae54a728e3ab8c08ab4c3e9f6a5beef9b4ca5a.zip
op-kernel-dev-00ae54a728e3ab8c08ab4c3e9f6a5beef9b4ca5a.tar.gz
[media] controls.xml: Document addtional Flash fault bits
Descriptions for flash faults V4L2_FLASH_FAULT_UNDER_VOLTAGE, V4L2_FLASH_FAULT_INPUT_VOLTAGE, and V4L2_FLASH_FAULT_LED_OVER_TEMPERATURE. Removed spaces before tabs. Signed-off-by: Daniel Jeong <gshark.jeong@gmail.com> Signed-off-by: Sakari Ailus <sakari.ailus@iki.fi> Signed-off-by: Mauro Carvalho Chehab <m.chehab@samsung.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/DocBook/media/v4l/controls.xml18
1 files changed, 18 insertions, 0 deletions
diff --git a/Documentation/DocBook/media/v4l/controls.xml b/Documentation/DocBook/media/v4l/controls.xml
index 28bf173..0340b962 100644
--- a/Documentation/DocBook/media/v4l/controls.xml
+++ b/Documentation/DocBook/media/v4l/controls.xml
@@ -4390,6 +4390,24 @@ interface and may change in the future.</para>
<entry>The flash controller has detected a short or open
circuit condition on the indicator LED.</entry>
</row>
+ <row>
+ <entry><constant>V4L2_FLASH_FAULT_UNDER_VOLTAGE</constant></entry>
+ <entry>Flash controller voltage to the flash LED
+ has been below the minimum limit specific to the flash
+ controller.</entry>
+ </row>
+ <row>
+ <entry><constant>V4L2_FLASH_FAULT_INPUT_VOLTAGE</constant></entry>
+ <entry>The input voltage of the flash controller is below
+ the limit under which strobing the flash at full current
+ will not be possible.The condition persists until this flag
+ is no longer set.</entry>
+ </row>
+ <row>
+ <entry><constant>V4L2_FLASH_FAULT_LED_OVER_TEMPERATURE</constant></entry>
+ <entry>The temperature of the LED has exceeded its
+ allowed upper limit.</entry>
+ </row>
</tbody>
</entrytbl>
</row>
OpenPOWER on IntegriCloud