summaryrefslogtreecommitdiffstats
path: root/Documentation/networking
diff options
context:
space:
mode:
authorDavid S. Miller <davem@davemloft.net>2017-03-24 13:45:07 -0700
committerDavid S. Miller <davem@davemloft.net>2017-03-24 13:45:07 -0700
commitba82427d4a0fdd92b01cb2a1c4c24990f37406a9 (patch)
treef482723e5448c72b606a85b998307eb203a6bf1b /Documentation/networking
parent6a18c312320766b6d13a12c681f77df04894f1a5 (diff)
parent584a88709bf4880ba5f8fed72da50512fbd9bdbb (diff)
downloadop-kernel-dev-ba82427d4a0fdd92b01cb2a1c4c24990f37406a9.zip
op-kernel-dev-ba82427d4a0fdd92b01cb2a1c4c24990f37406a9.tar.gz
Merge branch '40GbE' of git://git.kernel.org/pub/scm/linux/kernel/git/jkirsher/next-queue
Jeff Kirsher says: ==================== 40GbE Intel Wired LAN Driver Updates 2017-03-23 This series contains updates to i40e and i40e.txt documentation. Jake provides all the changes in the series which are centered around ntuple filter fixes and additional support. Fixed the current implementation of .set_rxnfc, where we were not reading the mask field for filter entries which was resulting in filters not behaving as expected and not working correctly. When cleaning up after disabling flow director support, ensure that the default input set is correctly reprogrammed. Since the hardware only supports a single input set for all flows of that type, the driver shall only allow the input set to change if there are no other configured filters for that flow type, so add support to detect when we can update the input set for each flow type. Align the driver to other drivers to partition the ring_cookie value into 8bits of VF index, along with 32bits of queue number instead of using the user-def field. Added support to parse the user-def field into a data structure format to allow future extensions of the user-def filed by keeping all the code that read/writes the field into a single location. Added support for flexible payloads passed via ethtool user-def field. We support a single flexible word (2byte) value per protocol type, and we handle the FLX_PIT register using a list of flexible entries so that each flow type may be configured separately. Enabled flow director filters for SCTPv4 packets using the ethtool ntuple interface to enable filters. Updated the documentation on the i40e driver to include the newly added support to ntuple filters. Reduced complexity of a if-continue-else-break section of code by taking advantage of using hlist_for_each_entry_continue() instead. ==================== Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'Documentation/networking')
-rw-r--r--Documentation/networking/i40e.txt72
1 files changed, 72 insertions, 0 deletions
diff --git a/Documentation/networking/i40e.txt b/Documentation/networking/i40e.txt
index a251bf4..57e616e 100644
--- a/Documentation/networking/i40e.txt
+++ b/Documentation/networking/i40e.txt
@@ -63,6 +63,78 @@ Additional Configurations
The latest release of ethtool can be found from
https://www.kernel.org/pub/software/network/ethtool
+
+ Flow Director n-ntuple traffic filters (FDir)
+ ---------------------------------------------
+ The driver utilizes the ethtool interface for configuring ntuple filters,
+ via "ethtool -N <device> <filter>".
+
+ The sctp4, ip4, udp4, and tcp4 flow types are supported with the standard
+ fields including src-ip, dst-ip, src-port and dst-port. The driver only
+ supports fully enabling or fully masking the fields, so use of the mask
+ fields for partial matches is not supported.
+
+ Additionally, the driver supports using the action to specify filters for a
+ Virtual Function. You can specify the action as a 64bit value, where the
+ lower 32 bits represents the queue number, while the next 8 bits represent
+ which VF. Note that 0 is the PF, so the VF identifier is offset by 1. For
+ example:
+
+ ... action 0x800000002 ...
+
+ Would indicate to direct traffic for Virtual Function 7 (8 minus 1) on queue
+ 2 of that VF.
+
+ The driver also supports using the user-defined field to specify 2 bytes of
+ arbitrary data to match within the packet payload in addition to the regular
+ fields. The data is specified in the lower 32bits of the user-def field in
+ the following way:
+
+ +----------------------------+---------------------------+
+ | 31 28 24 20 16 | 15 12 8 4 0|
+ +----------------------------+---------------------------+
+ | offset into packet payload | 2 bytes of flexible data |
+ +----------------------------+---------------------------+
+
+ As an example,
+
+ ... user-def 0x4FFFF ....
+
+ means to match the value 0xFFFF 4 bytes into the packet payload. Note that
+ the offset is based on the beginning of the payload, and not the beginning
+ of the packet. Thus
+
+ flow-type tcp4 ... user-def 0x8BEAF ....
+
+ would match TCP/IPv4 packets which have the value 0xBEAF 8bytes into the
+ TCP/IPv4 payload.
+
+ For ICMP, the hardware parses the ICMP header as 4 bytes of header and 4
+ bytes of payload, so if you want to match an ICMP frames payload you may need
+ to add 4 to the offset in order to match the data.
+
+ Furthermore, the offset can only be up to a value of 64, as the hardware
+ will only read up to 64 bytes of data from the payload. It must also be even
+ as the flexible data is 2 bytes long and must be aligned to byte 0 of the
+ packet payload.
+
+ When programming filters, the hardware is limited to using a single input
+ set for each flow type. This means that it is an error to program two
+ different filters with the same type that don't match on the same fields.
+ Thus the second of the following two commands will fail:
+
+ ethtool -N <device> flow-type tcp4 src-ip 192.168.0.7 action 5
+ ethtool -N <device> flow-type tcp4 dst-ip 192.168.15.18 action 1
+
+ This is because the first filter will be accepted and reprogram the input
+ set for TCPv4 filters, but the second filter will be unable to reprogram the
+ input set until all the conflicting TCPv4 filters are first removed.
+
+ Note that the user-defined flexible offset is also considered part of the
+ input set and cannot be programmed separately for multiple filters of the
+ same type. However, the flexible data is not part of the input set and
+ multiple filters may use the same offset but match against different data.
+
Data Center Bridging (DCB)
--------------------------
DCB configuration is not currently supported.
OpenPOWER on IntegriCloud