diff options
author | Iain Paton <ipaton0@gmail.com> | 2012-06-27 08:55:11 +0000 |
---|---|---|
committer | Guenter Roeck <linux@roeck-us.net> | 2012-07-21 21:48:44 -0700 |
commit | 27f8b1355504744e7cfbb5756f120734d58644a8 (patch) | |
tree | 3f30ded2736a1692a8ff3ff92406775a11b8d7fb /Documentation/hwmon | |
parent | edf48f3a73b027a99c92edab2b07d78fe77523cc (diff) | |
download | op-kernel-dev-27f8b1355504744e7cfbb5756f120734d58644a8.zip op-kernel-dev-27f8b1355504744e7cfbb5756f120734d58644a8.tar.gz |
hwmon: Honeywell Humidicon HIH-6130/HIH-6131 humidity and temperature sensor driver
This is a new driver for the Honeywell Humidicon HIH-6130/HIH-6131 humidity sensor.
The driver is based on the existing Sensiron sht21 driver with the necessary changes
to the probe, update_measurements and conversion functions necessary to use the
Honeywell sensors.
There's no difference between the 6130 & 6131 other than the 6131 having an external
condensation filter attached.
Signed-off-by: Iain Paton <ipaton0@gmail.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/hih6130 | 37 |
1 files changed, 37 insertions, 0 deletions
diff --git a/Documentation/hwmon/hih6130 b/Documentation/hwmon/hih6130 new file mode 100644 index 0000000..73dae91 --- /dev/null +++ b/Documentation/hwmon/hih6130 @@ -0,0 +1,37 @@ +Kernel driver hih6130 +===================== + +Supported chips: + * Honeywell HIH-6130 / HIH-6131 + Prefix: 'hih6130' + Addresses scanned: none + Datasheet: Publicly available at the Honeywell website + http://sensing.honeywell.com/index.php?ci_id=3106&la_id=1&defId=44872 + +Author: + Iain Paton <ipaton0@gmail.com> + +Description +----------- + +The HIH-6130 & HIH-6131 are humidity and temperature sensors in a SO8 package. +The difference between the two devices is that the HIH-6131 has a condensation +filter. + +The devices communicate with the I2C protocol. All sensors are set to the same +I2C address 0x27 by default, so an entry with I2C_BOARD_INFO("hih6130", 0x27) +can be used in the board setup code. + +Please see Documentation/i2c/instantiating-devices for details on how to +instantiate I2C devices. + +sysfs-Interface +--------------- + +temp1_input - temperature input +humidity1_input - humidity input + +Notes +----- + +Command mode and alarms are not currently supported. |