diff options
author | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-05-20 07:28:06 -0700 |
---|---|---|
committer | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-05-21 07:22:10 -0700 |
commit | 5e99c2f1e0c86d27ed2a5261442126cd0935bc69 (patch) | |
tree | d18e443f9baee186c6c26b344cfdd0d166d82278 /Documentation/hwmon | |
parent | 199e0de7f5df31a4fc485d4aaaf8a07718252ace (diff) | |
download | op-kernel-dev-5e99c2f1e0c86d27ed2a5261442126cd0935bc69.zip op-kernel-dev-5e99c2f1e0c86d27ed2a5261442126cd0935bc69.tar.gz |
hwmon: Remove pkgtemp driver
After the merge of pkgtemp functionality into the coretemp driver,
the pkgtemp driver is no longer necessary. Remove it.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Cc: Fenghua Yu <fenghua.yu@intel.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/pkgtemp | 36 |
1 files changed, 0 insertions, 36 deletions
diff --git a/Documentation/hwmon/pkgtemp b/Documentation/hwmon/pkgtemp deleted file mode 100644 index c8e1fb0..0000000 --- a/Documentation/hwmon/pkgtemp +++ /dev/null @@ -1,36 +0,0 @@ -Kernel driver pkgtemp -====================== - -Supported chips: - * Intel family - Prefix: 'pkgtemp' - CPUID: - Datasheet: Intel 64 and IA-32 Architectures Software Developer's Manual - Volume 3A: System Programming Guide - -Author: Fenghua Yu - -Description ------------ - -This driver permits reading package level temperature sensor embedded inside -Intel CPU package. The sensors can be in core, uncore, memory controller, or -other components in a package. The feature is first implemented in Intel Sandy -Bridge platform. - -Temperature is measured in degrees Celsius and measurement resolution is -1 degree C. Valid temperatures are from 0 to TjMax degrees C, because the actual -value of temperature register is in fact a delta from TjMax. - -Temperature known as TjMax is the maximum junction temperature of package. -We get this from MSR_IA32_TEMPERATURE_TARGET. If the MSR is not accessible, -we define TjMax as 100 degrees Celsius. At this temperature, protection -mechanism will perform actions to forcibly cool down the package. Alarm -may be raised, if the temperature grows enough (more than TjMax) to trigger -the Out-Of-Spec bit. Following table summarizes the exported sysfs files: - -temp1_input - Package temperature (in millidegrees Celsius). -temp1_max - All cooling devices should be turned on. -temp1_crit - Maximum junction temperature (in millidegrees Celsius). -temp1_crit_alarm - Set when Out-of-spec bit is set, never clears. - Correct CPU operation is no longer guaranteed. |