diff options
author | Guenter Roeck <linux@roeck-us.net> | 2012-02-24 08:13:31 -0800 |
---|---|---|
committer | Guenter Roeck <guenter.roeck@ericsson.com> | 2012-03-18 18:27:49 -0700 |
commit | 56aad5d143cbce620c079e1acf761b71f59758a0 (patch) | |
tree | 39705a8f7d580d9d1b352aac5d5bc5e69393db15 /Documentation/hwmon/max34440 | |
parent | f15df57ded710bd018794a264b900975ce3599a0 (diff) | |
download | op-kernel-dev-56aad5d143cbce620c079e1acf761b71f59758a0.zip op-kernel-dev-56aad5d143cbce620c079e1acf761b71f59758a0.tar.gz |
hwmon: (max34440) Add support for 'lowest' output voltage attribute
MAX34440 and compatibles support reporting the lowest measured output voltage.
Add support for it.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Acked-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/hwmon/max34440')
-rw-r--r-- | Documentation/hwmon/max34440 | 1 |
1 files changed, 1 insertions, 0 deletions
diff --git a/Documentation/hwmon/max34440 b/Documentation/hwmon/max34440 index 8ab5153..36b335c 100644 --- a/Documentation/hwmon/max34440 +++ b/Documentation/hwmon/max34440 @@ -56,6 +56,7 @@ in[1-6]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. in[1-6]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. in[1-6]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. in[1-6]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. +in[1-6]_lowest Historical minimum voltage. in[1-6]_highest Historical maximum voltage. in[1-6]_reset_history Write any value to reset history. |