diff options
author | Andi Kleen <ak@suse.de> | 2005-07-28 21:15:42 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@g5.osdl.org> | 2005-07-28 21:46:01 -0700 |
commit | f8d311939f9d2b2a5e935df8dceb98b7cbe08d43 (patch) | |
tree | 02da12ff661ee3da44e29e4ca89df28dea8a4593 | |
parent | 37a47e65fa58d413a31f27ee88f6cb98583b6157 (diff) | |
download | op-kernel-dev-f8d311939f9d2b2a5e935df8dceb98b7cbe08d43.zip op-kernel-dev-f8d311939f9d2b2a5e935df8dceb98b7cbe08d43.tar.gz |
[PATCH] x86_64: Support more than 8 cores on AMD systems
Use physical mode instead of logical mode to address more CPUs. This is also
used in the CPU hotplug case to avoid a race.
Signed-off-by: Andi Kleen <ak@suse.de>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
-rw-r--r-- | arch/x86_64/kernel/genapic.c | 33 | ||||
-rw-r--r-- | arch/x86_64/kernel/genapic_flat.c | 62 |
2 files changed, 85 insertions, 10 deletions
diff --git a/arch/x86_64/kernel/genapic.c b/arch/x86_64/kernel/genapic.c index 69b9c25..30c843a 100644 --- a/arch/x86_64/kernel/genapic.c +++ b/arch/x86_64/kernel/genapic.c @@ -31,6 +31,7 @@ u8 x86_cpu_to_log_apicid[NR_CPUS] = { [0 ... NR_CPUS-1] = BAD_APICID }; extern struct genapic apic_cluster; extern struct genapic apic_flat; +extern struct genapic apic_physflat; struct genapic *genapic = &apic_flat; @@ -44,12 +45,7 @@ void __init clustered_apic_check(void) u8 clusters, max_cluster; u8 id; u8 cluster_cnt[NUM_APIC_CLUSTERS]; - - if (boot_cpu_data.x86_vendor == X86_VENDOR_AMD) { - /* AMD always uses flat mode right now */ - genapic = &apic_flat; - goto print; - } + int num_cpus = 0; #if defined(CONFIG_ACPI_BUS) /* @@ -64,15 +60,34 @@ void __init clustered_apic_check(void) #endif memset(cluster_cnt, 0, sizeof(cluster_cnt)); - for (i = 0; i < NR_CPUS; i++) { id = bios_cpu_apicid[i]; - if (id != BAD_APICID) - cluster_cnt[APIC_CLUSTERID(id)]++; + if (id == BAD_APICID) + continue; + num_cpus++; + cluster_cnt[APIC_CLUSTERID(id)]++; } + /* Don't use clustered mode on AMD platforms. */ + if (boot_cpu_data.x86_vendor == X86_VENDOR_AMD) { + genapic = &apic_physflat; +#ifndef CONFIG_CPU_HOTPLUG + /* In the CPU hotplug case we cannot use broadcast mode + because that opens a race when a CPU is removed. + Stay at physflat mode in this case. + It is bad to do this unconditionally though. Once + we have ACPI platform support for CPU hotplug + we should detect hotplug capablity from ACPI tables and + only do this when really needed. -AK */ + if (num_cpus <= 8) + genapic = &apic_flat; +#endif + goto print; + } + clusters = 0; max_cluster = 0; + for (i = 0; i < NUM_APIC_CLUSTERS; i++) { if (cluster_cnt[i] > 0) { ++clusters; diff --git a/arch/x86_64/kernel/genapic_flat.c b/arch/x86_64/kernel/genapic_flat.c index fdfa15f..adc9628 100644 --- a/arch/x86_64/kernel/genapic_flat.c +++ b/arch/x86_64/kernel/genapic_flat.c @@ -2,7 +2,7 @@ * Copyright 2004 James Cleverdon, IBM. * Subject to the GNU Public License, v.2 * - * Flat APIC subarch code. Maximum 8 CPUs, logical delivery. + * Flat APIC subarch code. * * Hacked for x86-64 by James Cleverdon from i386 architecture code by * Martin Bligh, Andi Kleen, James Bottomley, John Stultz, and @@ -119,3 +119,63 @@ struct genapic apic_flat = { .cpu_mask_to_apicid = flat_cpu_mask_to_apicid, .phys_pkg_id = phys_pkg_id, }; + +/* + * Physflat mode is used when there are more than 8 CPUs on a AMD system. + * We cannot use logical delivery in this case because the mask + * overflows, so use physical mode. + */ + +static cpumask_t physflat_target_cpus(void) +{ + return cpumask_of_cpu(0); +} + +static void physflat_send_IPI_mask(cpumask_t cpumask, int vector) +{ + send_IPI_mask_sequence(cpumask, vector); +} + +static void physflat_send_IPI_allbutself(int vector) +{ + cpumask_t allbutme = cpu_online_map; + int me = get_cpu(); + cpu_clear(me, allbutme); + physflat_send_IPI_mask(allbutme, vector); + put_cpu(); +} + +static void physflat_send_IPI_all(int vector) +{ + physflat_send_IPI_mask(cpu_online_map, vector); +} + +static unsigned int physflat_cpu_mask_to_apicid(cpumask_t cpumask) +{ + int cpu; + + /* + * We're using fixed IRQ delivery, can only return one phys APIC ID. + * May as well be the first. + */ + cpu = first_cpu(cpumask); + if ((unsigned)cpu < NR_CPUS) + return x86_cpu_to_apicid[cpu]; + else + return BAD_APICID; +} + +struct genapic apic_physflat = { + .name = "physical flat", + .int_delivery_mode = dest_LowestPrio, + .int_dest_mode = (APIC_DEST_PHYSICAL != 0), + .int_delivery_dest = APIC_DEST_PHYSICAL | APIC_DM_LOWEST, + .target_cpus = physflat_target_cpus, + .apic_id_registered = flat_apic_id_registered, + .init_apic_ldr = flat_init_apic_ldr,/*not needed, but shouldn't hurt*/ + .send_IPI_all = physflat_send_IPI_all, + .send_IPI_allbutself = physflat_send_IPI_allbutself, + .send_IPI_mask = physflat_send_IPI_mask, + .cpu_mask_to_apicid = physflat_cpu_mask_to_apicid, + .phys_pkg_id = phys_pkg_id, +}; |