summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorJames Hogan <james.hogan@imgtec.com>2015-01-27 21:45:53 +0000
committerRalf Baechle <ralf@linux-mips.org>2015-03-31 12:04:12 +0200
commita1ec0e18833088673d2bdfe6e89b67b4f6ab00d7 (patch)
tree960b62524aedbc69dae741f4498e97679e0f434f
parentf0c5b8944b39896821e5d64b2d731564498160a9 (diff)
downloadop-kernel-dev-a1ec0e18833088673d2bdfe6e89b67b4f6ab00d7.zip
op-kernel-dev-a1ec0e18833088673d2bdfe6e89b67b4f6ab00d7.tar.gz
MIPS: perf: Allow sharing IRQ with timer
When requesting the performance counter overflow interrupt, pass flags which are compatible with the cevt-r4k driver, in particular IRQF_SHARED so that the two handlers can share the same IRQ. This is possible since release 2 of the architecture where there are separate pending interrupt bits for the timer interrupt and the performance counter interrupt. This will be necessary since the FDC interrupt can also be arbitrarily routed to a CPU interrupt, possibly sharing with the timer, the performance counters, or both, and it isn't scalable to have all the handlers able to call other handlers that may be on the same IRQ line. Shared handlers must also have a unique device pointer so they can be individually removed, so &mipspmu is now passed in for that instead of NULL. Signed-off-by: James Hogan <james.hogan@imgtec.com> Cc: Arnaldo Carvalho de Melo <acme@kernel.org> Cc: Ingo Molnar <mingo@redhat.com> Cc: Paul Mackerras <paulus@samba.org> Cc: Peter Zijlstra <a.p.zijlstra@chello.nl> Cc: linux-mips@linux-mips.org Cc: linux-kernel@vger.kernel.org Patchwork: https://patchwork.linux-mips.org/patch/9129/ Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
-rw-r--r--arch/mips/kernel/perf_event_mipsxx.c8
1 files changed, 5 insertions, 3 deletions
diff --git a/arch/mips/kernel/perf_event_mipsxx.c b/arch/mips/kernel/perf_event_mipsxx.c
index 76bc3bb..9d90efe 100644
--- a/arch/mips/kernel/perf_event_mipsxx.c
+++ b/arch/mips/kernel/perf_event_mipsxx.c
@@ -558,8 +558,10 @@ static int mipspmu_get_irq(void)
if (mipspmu.irq >= 0) {
/* Request my own irq handler. */
err = request_irq(mipspmu.irq, mipsxx_pmu_handle_irq,
- IRQF_PERCPU | IRQF_NOBALANCING | IRQF_NO_THREAD,
- "mips_perf_pmu", NULL);
+ IRQF_PERCPU | IRQF_NOBALANCING |
+ IRQF_NO_THREAD | IRQF_NO_SUSPEND |
+ IRQF_SHARED,
+ "mips_perf_pmu", &mipspmu);
if (err) {
pr_warn("Unable to request IRQ%d for MIPS performance counters!\n",
mipspmu.irq);
@@ -582,7 +584,7 @@ static int mipspmu_get_irq(void)
static void mipspmu_free_irq(void)
{
if (mipspmu.irq >= 0)
- free_irq(mipspmu.irq, NULL);
+ free_irq(mipspmu.irq, &mipspmu);
else if (cp0_perfcount_irq < 0)
perf_irq = save_perf_irq;
}
OpenPOWER on IntegriCloud