s390/zcrypt: fixed ap poll timer behavior
The ap poll timer restart condition was wrong. Hence the poll timer was not restarted reliable when setting a new time interval via the poll_timeout sysfs attribute. Added missing timer locking. Reported-by: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Ingo Tuchscherer <ingo.tuchscherer@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
-rw-r--r--drivers/s390/crypto/ap_bus.c16
1 files changed, 7 insertions, 9 deletions
diff --git a/drivers/s390/crypto/ap_bus.c b/drivers/s390/crypto/ap_bus.c
index f0b9871..6e506a8 100644
--- a/drivers/s390/crypto/ap_bus.c
+++ b/drivers/s390/crypto/ap_bus.c
@@ -1158,11 +1158,12 @@ static ssize_t poll_timeout_store(struct bus_type *bus, const char *buf,
poll_timeout = time;
hr_time = ktime_set(0, poll_timeout);
- if (!hrtimer_is_queued(&ap_poll_timer) ||
- !hrtimer_forward(&ap_poll_timer, hrtimer_get_expires(&ap_poll_timer), hr_time)) {
- hrtimer_set_expires(&ap_poll_timer, hr_time);
- hrtimer_start_expires(&ap_poll_timer, HRTIMER_MODE_ABS);
- }
+ spin_lock_bh(&ap_poll_timer_lock);
+ hrtimer_cancel(&ap_poll_timer);
+ hrtimer_set_expires(&ap_poll_timer, hr_time);
+ hrtimer_start_expires(&ap_poll_timer, HRTIMER_MODE_ABS);
+ spin_unlock_bh(&ap_poll_timer_lock);
+
return count;
}
@@ -1528,14 +1529,11 @@ static inline void __ap_schedule_poll_timer(void)
ktime_t hr_time;
spin_lock_bh(&ap_poll_timer_lock);
- if (hrtimer_is_queued(&ap_poll_timer) || ap_suspend_flag)
- goto out;
- if (ktime_to_ns(hrtimer_expires_remaining(&ap_poll_timer)) <= 0) {
+ if (!hrtimer_is_queued(&ap_poll_timer) && !ap_suspend_flag) {
hr_time = ktime_set(0, poll_timeout);
hrtimer_forward_now(&ap_poll_timer, hr_time);
hrtimer_restart(&ap_poll_timer);
}
-out:
spin_unlock_bh(&ap_poll_timer_lock);
}
OpenPOWER on IntegriCloud