summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorRoger Quadros <rogerq@ti.com>2014-09-10 08:57:11 -0700
committerTony Lindgren <tony@atomide.com>2014-09-10 08:57:11 -0700
commit5990047cef0c6a36eefcb166bd32d99a8f95c75b (patch)
treec444b9c92c5dba23df08b94c554c02ab0a7ac23d
parent2ce7598c9a453e0acd0e07be7be3f5eb39608ebd (diff)
downloadop-kernel-dev-5990047cef0c6a36eefcb166bd32d99a8f95c75b.zip
op-kernel-dev-5990047cef0c6a36eefcb166bd32d99a8f95c75b.tar.gz
ARM: dts: dra7-evm: Fix NAND GPMC timings
The nand timings were scaled down by 2 to account for the 2x rate returned by clk_get_rate(gpmc_fclk). As the clock data got fixed by [1], revert back to actual timings (i.e. scale them up by 2). Without this NAND doesn't work on dra7-evm. [1] - commit dd94324b983afe114ba9e7ee3649313b451f63ce ARM: dts: dra7xx-clocks: Fix the l3 and l4 clock rates Fixes: ff66a3c86e00 ("ARM: dts: dra7: add support for parallel NAND flash") Cc: <stable@vger.kernel.org> [3.16] Signed-off-by: Roger Quadros <rogerq@ti.com> Signed-off-by: Tony Lindgren <tony@atomide.com>
-rw-r--r--arch/arm/boot/dts/dra7-evm.dts27
1 files changed, 12 insertions, 15 deletions
diff --git a/arch/arm/boot/dts/dra7-evm.dts b/arch/arm/boot/dts/dra7-evm.dts
index e03fbf3..b40cdad 100644
--- a/arch/arm/boot/dts/dra7-evm.dts
+++ b/arch/arm/boot/dts/dra7-evm.dts
@@ -447,22 +447,19 @@
gpmc,device-width = <2>;
gpmc,sync-clk-ps = <0>;
gpmc,cs-on-ns = <0>;
- gpmc,cs-rd-off-ns = <40>;
- gpmc,cs-wr-off-ns = <40>;
+ gpmc,cs-rd-off-ns = <80>;
+ gpmc,cs-wr-off-ns = <80>;
gpmc,adv-on-ns = <0>;
- gpmc,adv-rd-off-ns = <30>;
- gpmc,adv-wr-off-ns = <30>;
- gpmc,we-on-ns = <5>;
- gpmc,we-off-ns = <25>;
- gpmc,oe-on-ns = <2>;
- gpmc,oe-off-ns = <20>;
- gpmc,access-ns = <20>;
- gpmc,wr-access-ns = <40>;
- gpmc,rd-cycle-ns = <40>;
- gpmc,wr-cycle-ns = <40>;
- gpmc,wait-pin = <0>;
- gpmc,wait-on-read;
- gpmc,wait-on-write;
+ gpmc,adv-rd-off-ns = <60>;
+ gpmc,adv-wr-off-ns = <60>;
+ gpmc,we-on-ns = <10>;
+ gpmc,we-off-ns = <50>;
+ gpmc,oe-on-ns = <4>;
+ gpmc,oe-off-ns = <40>;
+ gpmc,access-ns = <40>;
+ gpmc,wr-access-ns = <80>;
+ gpmc,rd-cycle-ns = <80>;
+ gpmc,wr-cycle-ns = <80>;
gpmc,bus-turnaround-ns = <0>;
gpmc,cycle2cycle-delay-ns = <0>;
gpmc,clk-activation-ns = <0>;
OpenPOWER on IntegriCloud