NVMe: Allocate queues only for online cpus
The driver previously requested allocating queues for the total possible number of CPUs so that blk-mq could rebalance these if CPUs were added after initialization. The number of hardware contexts can now be changed at runtime, so we only need to allocate the number of online queues since we can add more later. Suggested-by: Jeff Lien <jeff.lien@hgst.com> Signed-off-by: Keith Busch <keith.busch@intel.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Jens Axboe <axboe@fb.com>
-rw-r--r--drivers/nvme/host/pci.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/nvme/host/pci.c b/drivers/nvme/host/pci.c
index 0f093f1..3c7b625 100644
--- a/drivers/nvme/host/pci.c
+++ b/drivers/nvme/host/pci.c
@@ -1394,7 +1394,7 @@ static int nvme_setup_io_queues(struct nvme_dev *dev)
struct pci_dev *pdev = to_pci_dev(dev->dev);
int result, i, vecs, nr_io_queues, size;
- nr_io_queues = num_possible_cpus();
+ nr_io_queues = num_online_cpus();
result = nvme_set_queue_count(&dev->ctrl, &nr_io_queues);
if (result < 0)
return result;