summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorAjit Khaparde <ajit.khaparde@emulex.com>2011-04-19 12:11:55 +0000
committerDavid S. Miller <davem@davemloft.net>2011-04-19 20:13:11 -0700
commitd0381c42aabdbd9402501d08ea44a89695ad58b4 (patch)
treeac4346135bd10d1fe86c9fc681896151085a0d74
parent187e87566d22b0d0e99b5ae7c6e18569ab5f6aee (diff)
downloadop-kernel-dev-d0381c42aabdbd9402501d08ea44a89695ad58b4.zip
op-kernel-dev-d0381c42aabdbd9402501d08ea44a89695ad58b4.tar.gz
be2net: add code to display default value of tx rate for VFs
This change will allow the default value of tx rate to be displayed when ip link show is called on a PF interface. Signed-off-by: Ajit Khaparde <ajit.khaparde@emulex.com> Signed-off-by: David S. Miller <davem@davemloft.net>
-rw-r--r--drivers/net/benet/be_main.c13
1 files changed, 13 insertions, 0 deletions
diff --git a/drivers/net/benet/be_main.c b/drivers/net/benet/be_main.c
index 77a6e7e..3529400 100644
--- a/drivers/net/benet/be_main.c
+++ b/drivers/net/benet/be_main.c
@@ -3082,9 +3082,22 @@ static int __devinit be_probe(struct pci_dev *pdev,
netif_carrier_off(netdev);
if (be_physfn(adapter) && adapter->sriov_enabled) {
+ u8 mac_speed;
+ bool link_up;
+ u16 vf, lnk_speed;
+
status = be_vf_eth_addr_config(adapter);
if (status)
goto unreg_netdev;
+
+ for (vf = 0; vf < num_vfs; vf++) {
+ status = be_cmd_link_status_query(adapter, &link_up,
+ &mac_speed, &lnk_speed, vf + 1);
+ if (!status)
+ adapter->vf_cfg[vf].vf_tx_rate = lnk_speed * 10;
+ else
+ goto unreg_netdev;
+ }
}
dev_info(&pdev->dev, "%s port %d\n", nic_name(pdev), adapter->port_num);
OpenPOWER on IntegriCloud