authorRalph Campbell <ralph.campbell@qlogic.com>2008-01-15 15:58:13 -0800
committerRoland Dreier <rolandd@cisco.com>2008-01-16 14:42:35 -0800
commit0a69631b2869093d7306e8f66cca8eb0a05aa919 (patch)
tree32788676e5f262d540d8da36ec3f76edda9cb262
parentcdf71a10c7b6432d9b48e292cca2c62a0b9fa6cf (diff)
downloadop-kernel-dev-0a69631b2869093d7306e8f66cca8eb0a05aa919.zip
op-kernel-dev-0a69631b2869093d7306e8f66cca8eb0a05aa919.tar.gz
IB/ipath: Fix receiving UD messages with immediate data
This fixes a small bug in ipath_ud_rcv()'s handling of UD messages with immediate data. We need to test whether immediate data is present and update the header size accordingly *before* testing the packet size from the header against the actual received length. Otherwise the wrong header size will be used and all messages with immediate data will be dropped. This bug keeps MVAPICH-UD and HP MPI from working at all on ipath devices. Signed-off-by: Ralph Campbell <ralph.campbell@qlogic.com> Signed-off-by: Roland Dreier <rolandd@cisco.com>
-rw-r--r--drivers/infiniband/hw/ipath/ipath_ud.c44
1 files changed, 22 insertions, 22 deletions
diff --git a/drivers/infiniband/hw/ipath/ipath_ud.c b/drivers/infiniband/hw/ipath/ipath_ud.c
index 16a2a93..b3df6f3 100644
--- a/drivers/infiniband/hw/ipath/ipath_ud.c
+++ b/drivers/infiniband/hw/ipath/ipath_ud.c
@@ -455,6 +455,28 @@ void ipath_ud_rcv(struct ipath_ibdev *dev, struct ipath_ib_header *hdr,
}
}
+ /*
+ * The opcode is in the low byte when its in network order
+ * (top byte when in host order).
+ */
+ opcode = be32_to_cpu(ohdr->bth[0]) >> 24;
+ if (qp->ibqp.qp_num > 1 &&
+ opcode == IB_OPCODE_UD_SEND_ONLY_WITH_IMMEDIATE) {
+ if (header_in_data) {
+ wc.imm_data = *(__be32 *) data;
+ data += sizeof(__be32);
+ } else
+ wc.imm_data = ohdr->u.ud.imm_data;
+ wc.wc_flags = IB_WC_WITH_IMM;
+ hdrsize += sizeof(u32);
+ } else if (opcode == IB_OPCODE_UD_SEND_ONLY) {
+ wc.imm_data = 0;
+ wc.wc_flags = 0;
+ } else {
+ dev->n_pkt_drops++;
+ goto bail;
+ }
+
/* Get the number of bytes the message was padded by. */
pad = (be32_to_cpu(ohdr->bth[0]) >> 20) & 3;
if (unlikely(tlen < (hdrsize + pad + 4))) {
@@ -482,28 +504,6 @@ void ipath_ud_rcv(struct ipath_ibdev *dev, struct ipath_ib_header *hdr,
wc.byte_len = tlen + sizeof(struct ib_grh);
/*
- * The opcode is in the low byte when its in network order
- * (top byte when in host order).
- */
- opcode = be32_to_cpu(ohdr->bth[0]) >> 24;
- if (qp->ibqp.qp_num > 1 &&
- opcode == IB_OPCODE_UD_SEND_ONLY_WITH_IMMEDIATE) {
- if (header_in_data) {
- wc.imm_data = *(__be32 *) data;
- data += sizeof(__be32);
- } else
- wc.imm_data = ohdr->u.ud.imm_data;
- wc.wc_flags = IB_WC_WITH_IMM;
- hdrsize += sizeof(u32);
- } else if (opcode == IB_OPCODE_UD_SEND_ONLY) {
- wc.imm_data = 0;
- wc.wc_flags = 0;
- } else {
- dev->n_pkt_drops++;
- goto bail;
- }
-
- /*
* Get the next work request entry to find where to put the data.
*/
if (qp->r_reuse_sge)
OpenPOWER on IntegriCloud