summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorMarc Zyngier <marc.zyngier@arm.com>2013-07-11 12:13:00 +0100
committerCatalin Marinas <catalin.marinas@arm.com>2013-07-19 15:57:08 +0100
commitff701306cd49aaff80fb852323b387812bc76491 (patch)
treef1a0a512999eca18132e785bf4d05d555fd28417
parentdb6f41063cbdb58b14846e600e6bc3f4e4c2e888 (diff)
downloadop-kernel-dev-ff701306cd49aaff80fb852323b387812bc76491.zip
op-kernel-dev-ff701306cd49aaff80fb852323b387812bc76491.tar.gz
arm64: use common reboot infrastructure
Commit 7b6d864b48d9 (reboot: arm: change reboot_mode to use enum reboot_mode) changed the way reboot is handled on arm, which has a direct impact on arm64 as we share the reset driver on the VE platform. The obvious fix is to move arm64 to use the same infrastructure. Signed-off-by: Marc Zyngier <marc.zyngier@arm.com> [catalin.marinas@arm.com: removed reboot_mode = REBOOT_HARD default setting] Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
-rw-r--r--arch/arm64/include/asm/system_misc.h3
-rw-r--r--arch/arm64/kernel/process.c2
2 files changed, 3 insertions, 2 deletions
diff --git a/arch/arm64/include/asm/system_misc.h b/arch/arm64/include/asm/system_misc.h
index a6e1750..7a18fab 100644
--- a/arch/arm64/include/asm/system_misc.h
+++ b/arch/arm64/include/asm/system_misc.h
@@ -23,6 +23,7 @@
#include <linux/compiler.h>
#include <linux/linkage.h>
#include <linux/irqflags.h>
+#include <linux/reboot.h>
struct pt_regs;
@@ -41,7 +42,7 @@ extern void show_pte(struct mm_struct *mm, unsigned long addr);
extern void __show_regs(struct pt_regs *);
void soft_restart(unsigned long);
-extern void (*arm_pm_restart)(char str, const char *cmd);
+extern void (*arm_pm_restart)(enum reboot_mode reboot_mode, const char *cmd);
#define UDBG_UNDEFINED (1 << 0)
#define UDBG_SYSCALL (1 << 1)
diff --git a/arch/arm64/kernel/process.c b/arch/arm64/kernel/process.c
index 46f02c3..1788bf6 100644
--- a/arch/arm64/kernel/process.c
+++ b/arch/arm64/kernel/process.c
@@ -132,7 +132,7 @@ void machine_restart(char *cmd)
/* Now call the architecture specific reboot code. */
if (arm_pm_restart)
- arm_pm_restart('h', cmd);
+ arm_pm_restart(reboot_mode, cmd);
/*
* Whoops - the architecture was unable to reboot.
OpenPOWER on IntegriCloud