summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorGuenter Roeck <guenter.roeck@ericsson.com>2011-03-06 10:56:52 -0800
committerGuenter Roeck <guenter.roeck@ericsson.com>2011-03-14 22:39:09 -0700
commitb49547a5df96bc755d6f96abb8503678af49d91c (patch)
treec7b09bb99d93bbb3becf765ce2103c38c321ba1a
parent954df6763cd84551a565a0c341d3401cf30b9d2d (diff)
downloadop-kernel-dev-b49547a5df96bc755d6f96abb8503678af49d91c.zip
op-kernel-dev-b49547a5df96bc755d6f96abb8503678af49d91c.tar.gz
hwmon: (pmbus) Improve support for paged temperature sensors
Assumption so far was that PMBus devices would support TEMP2 and TEMP3 registers only on page 0, and that only the TEMP1 register would be used/supported on other pages. Turns out that is not correct. UCD92xx devices support TEMP1 and TEMP2 on page 0, and TEMP2 on other pages. So it is necessary to change the core code such that it does not make a page based assumptions about temperature register support. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
-rw-r--r--drivers/hwmon/pmbus_core.c46
1 files changed, 28 insertions, 18 deletions
diff --git a/drivers/hwmon/pmbus_core.c b/drivers/hwmon/pmbus_core.c
index d025a11..e9dda58 100644
--- a/drivers/hwmon/pmbus_core.c
+++ b/drivers/hwmon/pmbus_core.c
@@ -797,6 +797,12 @@ static const int pmbus_temp_registers[] = {
PMBUS_READ_TEMPERATURE_3
};
+static const int pmbus_temp_flags[] = {
+ PMBUS_HAVE_TEMP,
+ PMBUS_HAVE_TEMP2,
+ PMBUS_HAVE_TEMP3
+};
+
static const int pmbus_fan_registers[] = {
PMBUS_READ_FAN_SPEED_1,
PMBUS_READ_FAN_SPEED_2,
@@ -871,17 +877,16 @@ static void pmbus_find_max_attr(struct i2c_client *client,
max_booleans += 2 * PMBUS_MAX_BOOLEANS_PER_FAN;
}
if (info->func[page] & PMBUS_HAVE_TEMP) {
- if (page == 0) {
- max_sensors +=
- ARRAY_SIZE(pmbus_temp_registers) *
- PMBUS_MAX_SENSORS_PER_TEMP;
- max_booleans +=
- ARRAY_SIZE(pmbus_temp_registers) *
- PMBUS_MAX_BOOLEANS_PER_TEMP;
- } else {
- max_sensors += PMBUS_MAX_SENSORS_PER_TEMP;
- max_booleans += PMBUS_MAX_BOOLEANS_PER_TEMP;
- }
+ max_sensors += PMBUS_MAX_SENSORS_PER_TEMP;
+ max_booleans += PMBUS_MAX_BOOLEANS_PER_TEMP;
+ }
+ if (info->func[page] & PMBUS_HAVE_TEMP2) {
+ max_sensors += PMBUS_MAX_SENSORS_PER_TEMP;
+ max_booleans += PMBUS_MAX_BOOLEANS_PER_TEMP;
+ }
+ if (info->func[page] & PMBUS_HAVE_TEMP3) {
+ max_sensors += PMBUS_MAX_SENSORS_PER_TEMP;
+ max_booleans += PMBUS_MAX_BOOLEANS_PER_TEMP;
}
}
data->max_sensors = max_sensors;
@@ -1273,18 +1278,23 @@ static void pmbus_find_attributes(struct i2c_client *client,
*/
in_index = 1;
for (page = 0; page < info->pages; page++) {
- int t, temps;
-
- if (!(info->func[page] & PMBUS_HAVE_TEMP))
- continue;
+ int t;
- temps = page ? 1 : ARRAY_SIZE(pmbus_temp_registers);
- for (t = 0; t < temps; t++) {
+ for (t = 0; t < ARRAY_SIZE(pmbus_temp_registers); t++) {
bool have_alarm = false;
+ /*
+ * A PMBus chip may support any combination of
+ * temperature registers on any page. So we can not
+ * abort after a failure to detect a register, but have
+ * to continue checking for all registers on all pages.
+ */
+ if (!(info->func[page] & pmbus_temp_flags[t]))
+ continue;
+
if (!pmbus_check_word_register
(client, page, pmbus_temp_registers[t]))
- break;
+ continue;
i0 = data->num_sensors;
pmbus_add_sensor(data, "temp", "input", in_index, page,
OpenPOWER on IntegriCloud