summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorVivek Natarajan <vnatarajan@atheros.com>2009-11-30 16:50:53 +0530
committerJohn W. Linville <linville@tuxdriver.com>2009-12-07 16:51:18 -0500
commit7c3f4bbedc241ddcd3abe1f419c356e625231da1 (patch)
tree98b1141a86d4ac65ae930e1c0cb15cd6a17d2a01
parentbc83b6819289c031c439a5aa18ba0fd539d14f3e (diff)
downloadop-kernel-dev-7c3f4bbedc241ddcd3abe1f419c356e625231da1.zip
op-kernel-dev-7c3f4bbedc241ddcd3abe1f419c356e625231da1.tar.gz
mac80211: Fix dynamic power save for scanning.
Not only ps_sdata but also IEEE80211_CONF_PS is to be considered before restoring PS in scan_ps_disable(). For instance, when ps_sdata is set but CONF_PS is not set just because the dynamic timer is still running, a sw scan leads to setting of CONF_PS in scan_ps_disable instead of restarting the dynamic PS timer. Also for the above case, a null data frame is to be sent after returning to operating channel which was not happening with the current implementation. This patch fixes this too. Signed-off-by: Vivek Natarajan <vnatarajan@atheros.com> Reviewed-by: Kalle Valo <kalle.valo@nokia.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>
-rw-r--r--net/mac80211/ieee80211_i.h1
-rw-r--r--net/mac80211/scan.c20
2 files changed, 17 insertions, 4 deletions
diff --git a/net/mac80211/ieee80211_i.h b/net/mac80211/ieee80211_i.h
index 419f186..91dc863 100644
--- a/net/mac80211/ieee80211_i.h
+++ b/net/mac80211/ieee80211_i.h
@@ -746,6 +746,7 @@ struct ieee80211_local {
unsigned int wmm_acm; /* bit field of ACM bits (BIT(802.1D tag)) */
bool pspolling;
+ bool scan_ps_enabled;
/*
* PS can only be enabled when we have exactly one managed
* interface (and monitors) in PS, this then points there.
diff --git a/net/mac80211/scan.c b/net/mac80211/scan.c
index 4cf387c..f1a4c71 100644
--- a/net/mac80211/scan.c
+++ b/net/mac80211/scan.c
@@ -227,7 +227,8 @@ static bool ieee80211_prep_hw_scan(struct ieee80211_local *local)
static void ieee80211_scan_ps_enable(struct ieee80211_sub_if_data *sdata)
{
struct ieee80211_local *local = sdata->local;
- bool ps = false;
+
+ local->scan_ps_enabled = false;
/* FIXME: what to do when local->pspolling is true? */
@@ -235,12 +236,13 @@ static void ieee80211_scan_ps_enable(struct ieee80211_sub_if_data *sdata)
cancel_work_sync(&local->dynamic_ps_enable_work);
if (local->hw.conf.flags & IEEE80211_CONF_PS) {
- ps = true;
+ local->scan_ps_enabled = true;
local->hw.conf.flags &= ~IEEE80211_CONF_PS;
ieee80211_hw_config(local, IEEE80211_CONF_CHANGE_PS);
}
- if (!ps || !(local->hw.flags & IEEE80211_HW_PS_NULLFUNC_STACK))
+ if (!(local->scan_ps_enabled) ||
+ !(local->hw.flags & IEEE80211_HW_PS_NULLFUNC_STACK))
/*
* If power save was enabled, no need to send a nullfunc
* frame because AP knows that we are sleeping. But if the
@@ -261,7 +263,7 @@ static void ieee80211_scan_ps_disable(struct ieee80211_sub_if_data *sdata)
if (!local->ps_sdata)
ieee80211_send_nullfunc(local, sdata, 0);
- else {
+ else if (local->scan_ps_enabled) {
/*
* In !IEEE80211_HW_PS_NULLFUNC_STACK case the hardware
* will send a nullfunc frame with the powersave bit set
@@ -277,6 +279,16 @@ static void ieee80211_scan_ps_disable(struct ieee80211_sub_if_data *sdata)
*/
local->hw.conf.flags |= IEEE80211_CONF_PS;
ieee80211_hw_config(local, IEEE80211_CONF_CHANGE_PS);
+ } else if (local->hw.conf.dynamic_ps_timeout > 0) {
+ /*
+ * If IEEE80211_CONF_PS was not set and the dynamic_ps_timer
+ * had been running before leaving the operating channel,
+ * restart the timer now and send a nullfunc frame to inform
+ * the AP that we are awake.
+ */
+ ieee80211_send_nullfunc(local, sdata, 0);
+ mod_timer(&local->dynamic_ps_timer, jiffies +
+ msecs_to_jiffies(local->hw.conf.dynamic_ps_timeout));
}
}
OpenPOWER on IntegriCloud