summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorMarko Kohtala <marko.kohtala@gmail.com>2006-01-06 00:19:49 -0800
committerLinus Torvalds <torvalds@g5.osdl.org>2006-01-06 08:33:57 -0800
commit6a19b41b35bf45fc27a46dccf26005b3f44c1aa1 (patch)
treed041d74fd511d1eba667492c060b61edc6f7b1cd
parent110bee75d2e03d3b4bcc74743dee5a21fe7b43bd (diff)
downloadop-kernel-dev-6a19b41b35bf45fc27a46dccf26005b3f44c1aa1.zip
op-kernel-dev-6a19b41b35bf45fc27a46dccf26005b3f44c1aa1.tar.gz
[PATCH] parport: Kconfig dependency fixes
Make drivers that use directly PC parport HW depend on PARPORT_PC rather than HW independent PARPORT. Signed-off-by: Marko Kohtala <marko.kohtala@gmail.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
-rw-r--r--drivers/block/Kconfig2
-rw-r--r--drivers/block/paride/Kconfig5
-rw-r--r--drivers/scsi/Kconfig8
3 files changed, 8 insertions, 7 deletions
diff --git a/drivers/block/Kconfig b/drivers/block/Kconfig
index c4b9d2a..139cbba 100644
--- a/drivers/block/Kconfig
+++ b/drivers/block/Kconfig
@@ -117,7 +117,7 @@ config BLK_DEV_XD
config PARIDE
tristate "Parallel port IDE device support"
- depends on PARPORT
+ depends on PARPORT_PC
---help---
There are many external CD-ROM and disk devices that connect through
your computer's parallel port. Most of them are actually IDE devices
diff --git a/drivers/block/paride/Kconfig b/drivers/block/paride/Kconfig
index 17ff405..c0d2854 100644
--- a/drivers/block/paride/Kconfig
+++ b/drivers/block/paride/Kconfig
@@ -4,11 +4,12 @@
# PARIDE doesn't need PARPORT, but if PARPORT is configured as a module,
# PARIDE must also be a module. The bogus CONFIG_PARIDE_PARPORT option
# controls the choices given to the user ...
+# PARIDE only supports PC style parports. Tough for USB or other parports...
config PARIDE_PARPORT
tristate
depends on PARIDE!=n
- default m if PARPORT=m
- default y if PARPORT!=m
+ default m if PARPORT_PC=m
+ default y if PARPORT_PC!=m
comment "Parallel IDE high-level drivers"
depends on PARIDE
diff --git a/drivers/scsi/Kconfig b/drivers/scsi/Kconfig
index 9e8254f..3c606cf 100644
--- a/drivers/scsi/Kconfig
+++ b/drivers/scsi/Kconfig
@@ -914,7 +914,7 @@ config SCSI_INIA100
config SCSI_PPA
tristate "IOMEGA parallel port (ppa - older drives)"
- depends on SCSI && PARPORT
+ depends on SCSI && PARPORT_PC
---help---
This driver supports older versions of IOMEGA's parallel port ZIP
drive (a 100 MB removable media device).
@@ -941,7 +941,7 @@ config SCSI_PPA
config SCSI_IMM
tristate "IOMEGA parallel port (imm - newer drives)"
- depends on SCSI && PARPORT
+ depends on SCSI && PARPORT_PC
---help---
This driver supports newer versions of IOMEGA's parallel port ZIP
drive (a 100 MB removable media device).
@@ -968,7 +968,7 @@ config SCSI_IMM
config SCSI_IZIP_EPP16
bool "ppa/imm option - Use slow (but safe) EPP-16"
- depends on PARPORT && (SCSI_PPA || SCSI_IMM)
+ depends on SCSI_PPA || SCSI_IMM
---help---
EPP (Enhanced Parallel Port) is a standard for parallel ports which
allows them to act as expansion buses that can handle up to 64
@@ -983,7 +983,7 @@ config SCSI_IZIP_EPP16
config SCSI_IZIP_SLOW_CTR
bool "ppa/imm option - Assume slow parport control register"
- depends on PARPORT && (SCSI_PPA || SCSI_IMM)
+ depends on SCSI_PPA || SCSI_IMM
help
Some parallel ports are known to have excessive delays between
changing the parallel port control register and good data being
OpenPOWER on IntegriCloud