summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorUlf Hansson <ulf.hansson@linaro.org>2013-01-09 17:19:54 +0100
committerRussell King <rmk+kernel@arm.linux.org.uk>2013-01-23 10:17:00 +0000
commitf4670daef5e81aa312f5a18f571dbd8169ce079e (patch)
treec4e2bb8d20c215851312ff7955154e32af7a0f48
parent8259293aee1d44d7ebf0c644ef48db835653ebc3 (diff)
downloadop-kernel-dev-f4670daef5e81aa312f5a18f571dbd8169ce079e.zip
op-kernel-dev-f4670daef5e81aa312f5a18f571dbd8169ce079e.tar.gz
ARM: 7623/1: mmc: mmci: Fixup clock gating when freq is 0 for ST-variants
In the ST Micro variant, the MMCICLOCK register must not be used to gate the clock. Instead use MMCIPOWER register and by clearing the PWR_ON bit to do this. Signed-off-by: Johan Rudholm <johan.rudholm@stericsson.com> Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org> Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
-rw-r--r--drivers/mmc/host/mmci.c13
1 files changed, 13 insertions, 0 deletions
diff --git a/drivers/mmc/host/mmci.c b/drivers/mmc/host/mmci.c
index b43e1ab..04efcdf 100644
--- a/drivers/mmc/host/mmci.c
+++ b/drivers/mmc/host/mmci.c
@@ -60,6 +60,7 @@ static unsigned int fmax = 515633;
* @blksz_datactrl16: true if Block size is at b16..b30 position in datactrl register
* @pwrreg_powerup: power up value for MMCIPOWER register
* @signal_direction: input/out direction of bus signals can be indicated
+ * @pwrreg_clkgate: MMCIPOWER register must be used to gate the clock
*/
struct variant_data {
unsigned int clkreg;
@@ -72,6 +73,7 @@ struct variant_data {
bool blksz_datactrl16;
u32 pwrreg_powerup;
bool signal_direction;
+ bool pwrreg_clkgate;
};
static struct variant_data variant_arm = {
@@ -96,6 +98,7 @@ static struct variant_data variant_u300 = {
.sdio = true,
.pwrreg_powerup = MCI_PWR_ON,
.signal_direction = true,
+ .pwrreg_clkgate = true,
};
static struct variant_data variant_nomadik = {
@@ -107,6 +110,7 @@ static struct variant_data variant_nomadik = {
.st_clkdiv = true,
.pwrreg_powerup = MCI_PWR_ON,
.signal_direction = true,
+ .pwrreg_clkgate = true,
};
static struct variant_data variant_ux500 = {
@@ -119,6 +123,7 @@ static struct variant_data variant_ux500 = {
.st_clkdiv = true,
.pwrreg_powerup = MCI_PWR_ON,
.signal_direction = true,
+ .pwrreg_clkgate = true,
};
static struct variant_data variant_ux500v2 = {
@@ -132,6 +137,7 @@ static struct variant_data variant_ux500v2 = {
.blksz_datactrl16 = true,
.pwrreg_powerup = MCI_PWR_ON,
.signal_direction = true,
+ .pwrreg_clkgate = true,
};
/*
@@ -1150,6 +1156,13 @@ static void mmci_set_ios(struct mmc_host *mmc, struct mmc_ios *ios)
}
}
+ /*
+ * If clock = 0 and the variant requires the MMCIPOWER to be used for
+ * gating the clock, the MCI_PWR_ON bit is cleared.
+ */
+ if (!ios->clock && variant->pwrreg_clkgate)
+ pwr &= ~MCI_PWR_ON;
+
spin_lock_irqsave(&host->lock, flags);
mmci_set_clkreg(host, ios->clock);
OpenPOWER on IntegriCloud