summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorSukadev Bhattiprolu <sukadev@linux.vnet.ibm.com>2017-08-30 21:42:23 -0400
committerArnaldo Carvalho de Melo <acme@redhat.com>2017-09-01 14:46:00 -0300
commit2a118e1bd22cad57318520d37e3a184b8846c6a2 (patch)
treec3778a50f901edf633d1fbf6bb0a91549e8b5346
parent4fb205392022ba99a45dd01a62c6e2df046e400a (diff)
downloadop-kernel-dev-2a118e1bd22cad57318520d37e3a184b8846c6a2.zip
op-kernel-dev-2a118e1bd22cad57318520d37e3a184b8846c6a2.tar.gz
perf vendor events powerpc: Remove duplicate events
Some POWER PMU event names have multiple/alternate event codes. These alternate event codes were listed in the POWER9 JSON files for reference. But the perf tool does not seem to handle duplicates cleanly. 'perf list' shows such duplicate events only once, but 'perf stat' ends up counting the first event code twice, multiplexing if necessary and we end up with double the event counts. Remove the duplicate event codes from the JSON files for now. Reported-by: Michael Petlan <mpetlan@redhat.com> Signed-off-by: Sukadev Bhattiprolu <sukadev@linux.vnet.ibm.com> Cc: Andi Kleen <andi@firstfloor.org> Cc: Anton Blanchard <anton@au1.ibm.com> Cc: Jiri Olsa <jolsa@redhat.com> Cc: Michael Ellerman <mpe@ellerman.id.au> Link: http://lkml.kernel.org/r/20170830231506.GB20351@us.ibm.com Signed-off-by: Arnaldo Carvalho de Melo <acme@redhat.com>
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power9/frontend.json7
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power9/other.json120
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power9/pipeline.json7
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power9/pmc.json7
4 files changed, 3 insertions, 138 deletions
diff --git a/tools/perf/pmu-events/arch/powerpc/power9/frontend.json b/tools/perf/pmu-events/arch/powerpc/power9/frontend.json
index 7e62c46..c63a919 100644
--- a/tools/perf/pmu-events/arch/powerpc/power9/frontend.json
+++ b/tools/perf/pmu-events/arch/powerpc/power9/frontend.json
@@ -80,11 +80,6 @@
"BriefDescription": "Load Missed L1, counted at execution time (can be greater than loads finished). LMQ merges are not included in this count. i.e. if a load instruction misses on an address that is already allocated on the LMQ, this event will not increment for that load). Note that this count is per slice, so if a load spans multiple slices this event will increment multiple times for a single load."
},
{,
- "EventCode": "0x400F0",
- "EventName": "PM_LD_MISS_L1",
- "BriefDescription": "Load Missed L1, counted at execution time (can be greater than loads finished). LMQ merges are not included in this count. i.e. if a load instruction misses on an address that is already allocated on the LMQ, this event will not increment for that load). Note that this count is per slice, so if a load spans multiple slices this event will increment multiple times for a single load."
- },
- {,
"EventCode": "0x2E01A",
"EventName": "PM_CMPLU_STALL_LSU_FLUSH_NEXT",
"BriefDescription": "Completion stall of one cycle because the LSU requested to flush the next iop in the sequence. It takes 1 cycle for the ISU to process this request before the LSU instruction is allowed to complete"
@@ -374,4 +369,4 @@
"EventName": "PM_IPTEG_FROM_L31_ECO_MOD",
"BriefDescription": "A Page Table Entry was loaded into the TLB with Modified (M) data from another core's ECO L3 on the same chip due to a instruction side request"
}
-] \ No newline at end of file
+]
diff --git a/tools/perf/pmu-events/arch/powerpc/power9/other.json b/tools/perf/pmu-events/arch/powerpc/power9/other.json
index 00f3d2a..54cc3be 100644
--- a/tools/perf/pmu-events/arch/powerpc/power9/other.json
+++ b/tools/perf/pmu-events/arch/powerpc/power9/other.json
@@ -605,11 +605,6 @@
"BriefDescription": "RC retries on PB for any load from core (excludes DCBFs)"
},
{,
- "EventCode": "0x3689E",
- "EventName": "PM_L2_RTY_LD",
- "BriefDescription": "RC retries on PB for any load from core (excludes DCBFs)"
- },
- {,
"EventCode": "0xE08C",
"EventName": "PM_LSU0_ERAT_HIT",
"BriefDescription": "Primary ERAT hit. There is no secondary ERAT"
@@ -715,11 +710,6 @@
"BriefDescription": "Lifetime, sample of RD machine 0 valid"
},
{,
- "EventCode": "0x468B4",
- "EventName": "PM_L3_RD0_BUSY",
- "BriefDescription": "Lifetime, sample of RD machine 0 valid"
- },
- {,
"EventCode": "0x46080",
"EventName": "PM_L2_DISP_ALL_L2MISS",
"BriefDescription": "All successful Ld/St dispatches for this thread that were an L2 miss (excludes i_l2mru_tch_reqs)"
@@ -850,21 +840,11 @@
"BriefDescription": "RC mach 0 Busy. Used by PMU to sample ave RC lifetime (mach0 used as sample point)"
},
{,
- "EventCode": "0x2608C",
- "EventName": "PM_RC0_BUSY",
- "BriefDescription": "RC mach 0 Busy. Used by PMU to sample ave RC lifetime (mach0 used as sample point)"
- },
- {,
"EventCode": "0x36082",
"EventName": "PM_L2_LD_DISP",
"BriefDescription": "All successful I-or-D side load dispatches for this thread (excludes i_l2mru_tch_reqs)."
},
{,
- "EventCode": "0x1609E",
- "EventName": "PM_L2_LD_DISP",
- "BriefDescription": "All successful D side load dispatches for this thread (L2 miss + L2 hits)"
- },
- {,
"EventCode": "0xF8B0",
"EventName": "PM_L3_SW_PREF",
"BriefDescription": "L3 load prefetch, sourced from a software prefetch stream, was sent to the nest"
@@ -1040,11 +1020,6 @@
"BriefDescription": "L3 castouts in Mepf state for this thread"
},
{,
- "EventCode": "0x168A0",
- "EventName": "PM_L3_CO_MEPF",
- "BriefDescription": "L3 CO of line in Mep state (includes casthrough to memory). The Mepf state indicates that a line was brought in to satisfy an L3 prefetch request"
- },
- {,
"EventCode": "0x460A2",
"EventName": "PM_L3_LAT_CI_HIT",
"BriefDescription": "L3 Lateral Castins Hit"
@@ -1150,11 +1125,6 @@
"BriefDescription": "RC retries on PB for any store from core (excludes DCBFs)"
},
{,
- "EventCode": "0x4689E",
- "EventName": "PM_L2_RTY_ST",
- "BriefDescription": "RC retries on PB for any store from core (excludes DCBFs)"
- },
- {,
"EventCode": "0x24040",
"EventName": "PM_INST_FROM_L2_MEPF",
"BriefDescription": "The processor's Instruction cache was reloaded from local core's L2 hit without dispatch conflicts on Mepf state. due to an instruction fetch (not prefetch)"
@@ -1255,11 +1225,6 @@
"BriefDescription": "CO mach 0 Busy. Used by PMU to sample ave CO lifetime (mach0 used as sample point)"
},
{,
- "EventCode": "0x4608C",
- "EventName": "PM_CO0_BUSY",
- "BriefDescription": "CO mach 0 Busy. Used by PMU to sample ave CO lifetime (mach0 used as sample point)"
- },
- {,
"EventCode": "0x2C122",
"EventName": "PM_MRK_DATA_FROM_L3_DISP_CONFLICT_CYC",
"BriefDescription": "Duration in cycles to reload from local core's L3 with dispatch conflict due to a marked load"
@@ -1395,11 +1360,6 @@
"BriefDescription": "A Page Table Entry was loaded into the TLB from the local chip's Memory due to a instruction side request"
},
{,
- "EventCode": "0x40006",
- "EventName": "PM_ISLB_MISS",
- "BriefDescription": "Number of ISLB misses for this thread"
- },
- {,
"EventCode": "0xD8A8",
"EventName": "PM_ISLB_MISS",
"BriefDescription": "Instruction SLB miss - Total of all segment sizes"
@@ -1515,11 +1475,6 @@
"BriefDescription": "All successful I-side dispatches for this thread (excludes i_l2mru_tch reqs)."
},
{,
- "EventCode": "0x3609E",
- "EventName": "PM_L2_INST",
- "BriefDescription": "All successful I-side dispatches that were an L2 miss for this thread (excludes i_l2mru_tch reqs)"
- },
- {,
"EventCode": "0x3504C",
"EventName": "PM_IPTEG_FROM_DL4",
"BriefDescription": "A Page Table Entry was loaded into the TLB from another chip's L4 on a different Node or Group (Distant) due to a instruction side request"
@@ -1690,11 +1645,6 @@
"BriefDescription": "All successful I-or-D side load dispatches for this thread that were L2 hits (excludes i_l2mru_tch_reqs)"
},
{,
- "EventCode": "0x2609E",
- "EventName": "PM_L2_LD_HIT",
- "BriefDescription": "All successful D side load dispatches for this thread that were L2 hits for this thread"
- },
- {,
"EventCode": "0x168AC",
"EventName": "PM_L3_CI_USAGE",
"BriefDescription": "Rotating sample of 16 CI or CO actives"
@@ -1795,21 +1745,11 @@
"BriefDescription": "Rotating sample of 8 WI valid"
},
{,
- "EventCode": "0x260B6",
- "EventName": "PM_L3_WI0_BUSY",
- "BriefDescription": "Rotating sample of 8 WI valid (duplicate)"
- },
- {,
"EventCode": "0x368AC",
"EventName": "PM_L3_CO0_BUSY",
"BriefDescription": "Lifetime, sample of CO machine 0 valid"
},
{,
- "EventCode": "0x468AC",
- "EventName": "PM_L3_CO0_BUSY",
- "BriefDescription": "Lifetime, sample of CO machine 0 valid"
- },
- {,
"EventCode": "0x2E040",
"EventName": "PM_DPTEG_FROM_L2_MEPF",
"BriefDescription": "A Page Table Entry was loaded into the TLB from local core's L2 hit without dispatch conflicts on Mepf state. due to a data side request. When using Radix Page Translation, this count excludes PDE reloads. Only PTE reloads are included"
@@ -1840,11 +1780,6 @@
"BriefDescription": "L3 PF received retry port 0, every retry counted"
},
{,
- "EventCode": "0x260AE",
- "EventName": "PM_L3_P0_PF_RTY",
- "BriefDescription": "L3 PF received retry port 0, every retry counted"
- },
- {,
"EventCode": "0x268B2",
"EventName": "PM_L3_LOC_GUESS_WRONG",
"BriefDescription": "Initial scope=node (LNS) but data from out side local node (near or far or rem). Prediction too Low"
@@ -1895,11 +1830,6 @@
"BriefDescription": "Lifetime, sample of snooper machine 0 valid"
},
{,
- "EventCode": "0x460AC",
- "EventName": "PM_L3_SN0_BUSY",
- "BriefDescription": "Lifetime, sample of snooper machine 0 valid"
- },
- {,
"EventCode": "0x3005C",
"EventName": "PM_BFU_BUSY",
"BriefDescription": "Cycles in which all 4 Binary Floating Point units are busy. The BFU is running at capacity"
@@ -1935,11 +1865,6 @@
"BriefDescription": "Lifetime, sample of PF machine 0 valid"
},
{,
- "EventCode": "0x460B4",
- "EventName": "PM_L3_PF0_BUSY",
- "BriefDescription": "Lifetime, sample of PF machine 0 valid"
- },
- {,
"EventCode": "0xC0B0",
"EventName": "PM_LSU_FLUSH_UE",
"BriefDescription": "Correctable ECC error on reload data, reported at critical data forward time"
@@ -2085,11 +2010,6 @@
"BriefDescription": "L3 CO received retry port 1 (memory only), every retry counted"
},
{,
- "EventCode": "0x468AE",
- "EventName": "PM_L3_P1_CO_RTY",
- "BriefDescription": "L3 CO received retry port 3 (memory only), every retry counted"
- },
- {,
"EventCode": "0xC0AC",
"EventName": "PM_LSU_FLUSH_EMSH",
"BriefDescription": "An ERAT miss was detected after a set-p hit. Erat tracker indicates fail due to tlbmiss and the instruction gets flushed because the instruction was working on the wrong address"
@@ -2195,11 +2115,6 @@
"BriefDescription": "SNP dispatched for a write and was M (true M); for DMA cacheinj this will pulse if rty/push is required (won't pulse if cacheinj is accepted)"
},
{,
- "EventCode": "0x46886",
- "EventName": "PM_L2_SN_M_WR_DONE",
- "BriefDescription": "SNP dispatched for a write and was M (true M); for DMA cacheinj this will pulse if rty/push is required (won't pulse if cacheinj is accepted)"
- },
- {,
"EventCode": "0x489C",
"EventName": "PM_BR_CORECT_PRED_TAKEN_CMPL",
"BriefDescription": "Conditional Branch Completed in which the HW correctly predicted the direction as taken. Counted at completion time"
@@ -2290,21 +2205,11 @@
"BriefDescription": "SN mach 0 Busy. Used by PMU to sample ave SN lifetime (mach0 used as sample point)"
},
{,
- "EventCode": "0x26090",
- "EventName": "PM_SN0_BUSY",
- "BriefDescription": "SN mach 0 Busy. Used by PMU to sample ave SN lifetime (mach0 used as sample point)"
- },
- {,
"EventCode": "0x360AE",
"EventName": "PM_L3_P0_CO_RTY",
"BriefDescription": "L3 CO received retry port 0 (memory only), every retry counted"
},
{,
- "EventCode": "0x460AE",
- "EventName": "PM_L3_P0_CO_RTY",
- "BriefDescription": "L3 CO received retry port 0 (memory only), every retry counted"
- },
- {,
"EventCode": "0x168A8",
"EventName": "PM_L3_WI_USAGE",
"BriefDescription": "Lifetime, sample of Write Inject machine 0 valid"
@@ -2340,26 +2245,11 @@
"BriefDescription": "L3 PF received retry port 1, every retry counted"
},
{,
- "EventCode": "0x268AE",
- "EventName": "PM_L3_P1_PF_RTY",
- "BriefDescription": "L3 PF received retry port 3, every retry counted"
- },
- {,
"EventCode": "0x46082",
"EventName": "PM_L2_ST_DISP",
"BriefDescription": "All successful D-side store dispatches for this thread "
},
{,
- "EventCode": "0x1689E",
- "EventName": "PM_L2_ST_DISP",
- "BriefDescription": "All successful D-side store dispatches for this thread (L2 miss + L2 hits)"
- },
- {,
- "EventCode": "0x36880",
- "EventName": "PM_L2_INST_MISS",
- "BriefDescription": "All successful I-side dispatches that were an L2 miss for this thread (excludes i_l2mru_tch reqs)"
- },
- {,
"EventCode": "0x4609E",
"EventName": "PM_L2_INST_MISS",
"BriefDescription": "All successful I-side dispatches that were an L2 miss for this thread (excludes i_l2mru_tch reqs)"
@@ -2430,11 +2320,6 @@
"BriefDescription": "# PPC Dispatched"
},
{,
- "EventCode": "0x300F2",
- "EventName": "PM_INST_DISP",
- "BriefDescription": "# PPC Dispatched"
- },
- {,
"EventCode": "0x4E05E",
"EventName": "PM_TM_OUTER_TBEGIN_DISP",
"BriefDescription": "Number of outer tbegin instructions dispatched. The dispatch unit determines whether the tbegin instruction is outer or nested. This is a speculative count, which includes flushed instructions"
@@ -2460,11 +2345,6 @@
"BriefDescription": "All successful D-side store dispatches for this thread that were L2 hits"
},
{,
- "EventCode": "0x2689E",
- "EventName": "PM_L2_ST_HIT",
- "BriefDescription": "All successful D-side store dispatches that were L2 hits for this thread"
- },
- {,
"EventCode": "0x360A8",
"EventName": "PM_L3_CO",
"BriefDescription": "L3 castout occurring (does not include casthrough or log writes (cinj/dmaw))"
diff --git a/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json b/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json
index 47a8256..bc2db63 100644
--- a/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json
+++ b/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json
@@ -420,11 +420,6 @@
"BriefDescription": "Final Pump Scope (Group) ended up larger than Initial Pump Scope (Chip) for an instruction fetch"
},
{,
- "EventCode": "0x10016",
- "EventName": "PM_DSLB_MISS",
- "BriefDescription": "Data SLB Miss - Total of all segment sizes"
- },
- {,
"EventCode": "0xD0A8",
"EventName": "PM_DSLB_MISS",
"BriefDescription": "Data SLB Miss - Total of all segment sizes"
@@ -554,4 +549,4 @@
"EventName": "PM_MRK_DATA_FROM_L21_SHR_CYC",
"BriefDescription": "Duration in cycles to reload with Shared (S) data from another core's L2 on the same chip due to a marked load"
}
-] \ No newline at end of file
+]
diff --git a/tools/perf/pmu-events/arch/powerpc/power9/pmc.json b/tools/perf/pmu-events/arch/powerpc/power9/pmc.json
index a2c95a9..3ef8a10 100644
--- a/tools/perf/pmu-events/arch/powerpc/power9/pmc.json
+++ b/tools/perf/pmu-events/arch/powerpc/power9/pmc.json
@@ -5,11 +5,6 @@
"BriefDescription": "Branches that are not strongly biased"
},
{,
- "EventCode": "0x40036",
- "EventName": "PM_BR_2PATH",
- "BriefDescription": "Branches that are not strongly biased"
- },
- {,
"EventCode": "0x40056",
"EventName": "PM_MEM_LOC_THRESH_LSU_HIGH",
"BriefDescription": "Local memory above threshold for LSU medium"
@@ -124,4 +119,4 @@
"EventName": "PM_1FLOP_CMPL",
"BriefDescription": "one flop (fadd, fmul, fsub, fcmp, fsel, fabs, fnabs, fres, fsqrte, fneg) operation completed"
}
-] \ No newline at end of file
+]
OpenPOWER on IntegriCloud