summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorMichael Roth <mdroth@linux.vnet.ibm.com>2016-04-25 17:24:25 -0500
committerTimothy Pearson <tpearson@raptorengineering.com>2019-11-29 20:03:50 -0600
commit94a26e6515f45b8ea8537bdb6f6dd73e15d4e749 (patch)
tree64b3fa645d25764ff7900fdbe63c2be0dab5ce41
parent5706dd536f0f842e3b84ea1b51cd812d704d97ff (diff)
downloadhqemu-94a26e6515f45b8ea8537bdb6f6dd73e15d4e749.zip
hqemu-94a26e6515f45b8ea8537bdb6f6dd73e15d4e749.tar.gz
spapr_drc: fix aborts during DRC-count based hotplug
CPU/memory resources can be signalled en-masse via spapr_hotplug_req_add_by_count(), and when doing so, actually change the meaning of the 'drc' parameter passed to spapr_hotplug_req_event() to be a count rather than an index. f40eb92 added a hook in spapr_hotplug_req_event() to record when a device had been 'signalled' to the guest, but that code assumes that drc is always an index. In cases where it's a count, such as memory hotplug, the DRC lookup will fail, leading to an assert. Fix this by only explicitly setting the signalled state for cases where we are doing PCI hotplug. For other resources types, since we cannot selectively track whether a resource has been signalled in cases where we signal attach as a count, set the 'signalled' state to true immediately upon making the resource available via drck->attach(). Reported-by: Bharata B Rao <bharata@linux.vnet.ibm.com> Cc: Bharata B Rao <bharata@linux.vnet.ibm.com> Cc: david@gibson.dropbear.id.au Cc: qemu-ppc@nongnu.org Signed-off-by: Michael Roth <mdroth@linux.vnet.ibm.com> Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
-rw-r--r--hw/ppc/spapr_drc.c12
-rw-r--r--hw/ppc/spapr_events.c7
2 files changed, 14 insertions, 5 deletions
diff --git a/hw/ppc/spapr_drc.c b/hw/ppc/spapr_drc.c
index 3173940..1f5f1d7 100644
--- a/hw/ppc/spapr_drc.c
+++ b/hw/ppc/spapr_drc.c
@@ -364,7 +364,17 @@ static void attach(sPAPRDRConnector *drc, DeviceState *d, void *fdt,
drc->fdt = fdt;
drc->fdt_start_offset = fdt_start_offset;
drc->configured = coldplug;
- drc->signalled = coldplug;
+ /* 'logical' DR resources such as memory/cpus are in some cases treated
+ * as a pool of resources from which the guest is free to choose from
+ * based on only a count. for resources that can be assigned in this
+ * fashion, we must assume the resource is signalled immediately
+ * since a single hotplug request might make an arbitrary number of
+ * such attached resources available to the guest, as opposed to
+ * 'physical' DR resources such as PCI where each device/resource is
+ * signalled individually.
+ */
+ drc->signalled = (drc->type != SPAPR_DR_CONNECTOR_TYPE_PCI)
+ ? true : coldplug;
object_property_add_link(OBJECT(drc), "device",
object_get_typename(OBJECT(drc->dev)),
diff --git a/hw/ppc/spapr_events.c b/hw/ppc/spapr_events.c
index 269ab7e..049fb1b 100644
--- a/hw/ppc/spapr_events.c
+++ b/hw/ppc/spapr_events.c
@@ -442,6 +442,9 @@ static void spapr_hotplug_req_event(uint8_t hp_id, uint8_t hp_action,
switch (drc_type) {
case SPAPR_DR_CONNECTOR_TYPE_PCI:
hp->hotplug_type = RTAS_LOG_V6_HP_TYPE_PCI;
+ if (hp->hotplug_action == RTAS_LOG_V6_HP_ACTION_ADD) {
+ spapr_hotplug_set_signalled(drc);
+ }
break;
case SPAPR_DR_CONNECTOR_TYPE_LMB:
hp->hotplug_type = RTAS_LOG_V6_HP_TYPE_MEMORY;
@@ -462,10 +465,6 @@ static void spapr_hotplug_req_event(uint8_t hp_id, uint8_t hp_action,
rtas_event_log_queue(RTAS_LOG_TYPE_HOTPLUG, new_hp, true);
- if (hp->hotplug_action == RTAS_LOG_V6_HP_ACTION_ADD) {
- spapr_hotplug_set_signalled(drc);
- }
-
qemu_irq_pulse(xics_get_qirq(spapr->icp, spapr->check_exception_irq));
}
OpenPOWER on IntegriCloud