summaryrefslogtreecommitdiffstats
path: root/usr.sbin/pciconf/pciconf.8
blob: 64d2f21a72f3ecb11ae7ae0cb7e4c308763426fa (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
.\" Copyright (c) 1997
.\"	Stefan Esser <se@FreeBSD.org>. All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\"    notice, this list of conditions and the following disclaimer.
.\"
.\" 2. Redistributions in binary form must reproduce the above copyright
.\"    notice, this list of conditions and the following disclaimer in the
.\"    documentation and/or other materials provided with the distribution.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" $FreeBSD$
.\"
.Dd November 7, 2007
.Dt PCICONF 8
.Os
.Sh NAME
.Nm pciconf
.Nd diagnostic utility for the PCI bus
.Sh SYNOPSIS
.Nm
.Fl l Op Fl cv
.Nm
.Fl a Ar selector
.Nm
.Fl r Oo Fl b | h Oc Ar selector addr Ns Op : Ns Ar addr2
.Nm
.Fl w Oo Fl b | h Oc Ar selector addr value
.Sh DESCRIPTION
The
.Nm
utility provides a command line interface to functionality provided by the
.Xr pci 4
.Xr ioctl 2
interface.
As such, some of the functions are only available to users with write
access to
.Pa /dev/pci ,
normally only the super-user.
.Pp
With the
.Fl l
option, it lists all devices found by the boot probe in the following format:
.Bd -literal
foo0@pci0:0:4:0: class=0x010000 card=0x00000000 chip=0x000f1000 rev=0x01 \
hdr=0x00
bar0@pci0:0:5:0: class=0x000100 card=0x00000000 chip=0x88c15333 rev=0x00 \
hdr=0x00
none0@pci0:0:6:0: class=0x020000 card=0x00000000 chip=0x802910ec rev=0x00 \
hdr=0x00
.Ed
.Pp
The first column gives the
device name, unit number, and
.Ar selector .
If there is no device configured in the kernel for the
.Tn PCI
device in question, the device name will be
.Dq none .
Unit numbers for unconfigured devices start at zero and are incremented for
each unconfigured device that is encountered.
The
.Ar selector
is in a form which may directly be used for the other forms of the command.
The second column is the class code, with the class byte printed as two
hex digits, followed by the sub-class and the interface bytes.
The third column gives the contents of the subvendorid register, introduced
in revision 2.1 of the
.Tn PCI
standard.
Note that it will be 0 for older cards.
The field consists of the card ID in the upper
half and the card vendor ID in the lower half of the value.
.Pp
The fourth column contains the chip device ID, which identifies the chip
this card is based on.
It consists of two fields, identifying the chip and
its vendor, as above.
The fifth column prints the chip's revision.
The sixth column describes the header type.
Currently assigned header types include 0 for most devices,
1 for
.Tn PCI
to
.Tn PCI
bridges, and 2 for
.Tn PCI
to
.Tn CardBus
bridges.
If the most significant bit
of the header type register is set for
function 0 of a
.Tn PCI
device, it is a
.Em multi-function
device, which contains several (similar or independent) functions on
one chip.
.Pp
If the
.Fl c
option is supplied,
.Nm
will list any capabilities supported by each device.
Each capability will be enumerated via a line in the following format:
.Bd -literal
    cap 10[40] = PCI-Express 1 root port
.Ed
.Pp
The first value after the
.Dq Li cap
prefix is the capability ID in hexadecimal.
The second value in the square brackets is the offset of the capability
in config space in hexadecimal.
The format of the text after the equals sign is capability-specific.
.Pp
If the
.Fl v
option is supplied,
.Nm
will attempt to load the vendor/device information database, and print
vendor, device, class and subclass identification strings for each device.
.Pp
All invocations of
.Nm
except for
.Fl l
require a
.Ar selector
of the form
.Li pci Ns Va domain Ns \&: Ns Va bus Ns \&: Ns Va device Ns \&: \
Ns Va function Ns ,
.Li pci Ns Va bus Ns \&: Ns Va device Ns \&: Ns Va function Ns , or
.Li pci Ns Va bus Ns \&: Ns Va device Ns .
In case of an abrigded form, omitted selector components are assumed to be 0.
An optional leading device name followed by @ and an optional final colon 
will be ignored; this is so that the first column in the output of
.Nm
.Fl l
can be used without modification.
All numbers are base 10.
.Pp
With the
.Fl a
flag,
.Nm
determines whether any driver has been assigned to the device
identified by
.Ar selector .
An exit status of zero indicates that the device has a driver;
non-zero indicates that it does not.
.Pp
The
.Fl r
option reads a configuration space register at byte offset
.Ar addr
of device
.Ar selector
and prints out its value in hexadecimal.
The optional second address
.Ar addr2
specifies a range to read.
The
.Fl w
option writes the
.Ar value
into a configuration space register at byte offset
.Ar addr
of device
.Ar selector .
For both operations, the flags
.Fl b
and
.Fl h
select the width of the operation;
.Fl b
indicates a byte operation, and
.Fl h
indicates a halfword (two-byte) operation.
The default is to read or
write a longword (four bytes).
.Sh ENVIRONMENT
The PCI vendor/device information database is normally read from
.Pa /usr/share/misc/pci_vendors .
This path can be overridden by setting the environment variable
.Ev PCICONF_VENDOR_DATABASE .
.Sh SEE ALSO
.Xr ioctl 2 ,
.\" .Xr pci 4 ,
.Xr devinfo 8 ,
.Xr kldload 8
.Sh HISTORY
The
.Nm
utility appeared first in
.Fx 2.2 .
The
.Fl a
option was added for
.Tn PCI
KLD support in
.Fx 3.0 .
.Sh AUTHORS
.An -nosplit
The
.Nm
utility was written by
.An Stefan Esser
and
.An Garrett Wollman .
.Sh BUGS
The
.Fl b
and
.Fl h
options are implemented in
.Nm ,
but not in the underlying
.Xr ioctl 2 .
.Pp
It might be useful to give non-root users access to the
.Fl a
and
.Fl r
options.
But only root will be able to execute a
.Nm kldload
to provide the device with a driver KLD, and reading of configuration space
registers may cause a failure in badly designed
.Tn PCI
chips.
OpenPOWER on IntegriCloud