summaryrefslogtreecommitdiffstats
path: root/sys/dev/raidframe/rf_raid5.c
blob: c1261ad88c449bc0cc247142cc028fead1db4223 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
/*	$FreeBSD$ */
/*	$NetBSD: rf_raid5.c,v 1.4 2000/01/08 22:57:30 oster Exp $	*/
/*
 * Copyright (c) 1995 Carnegie-Mellon University.
 * All rights reserved.
 *
 * Author: Mark Holland
 *
 * Permission to use, copy, modify and distribute this software and
 * its documentation is hereby granted, provided that both the copyright
 * notice and this permission notice appear in all copies of the
 * software, derivative works or modified versions, and any portions
 * thereof, and that both notices appear in supporting documentation.
 *
 * CARNEGIE MELLON ALLOWS FREE USE OF THIS SOFTWARE IN ITS "AS IS"
 * CONDITION.  CARNEGIE MELLON DISCLAIMS ANY LIABILITY OF ANY KIND
 * FOR ANY DAMAGES WHATSOEVER RESULTING FROM THE USE OF THIS SOFTWARE.
 *
 * Carnegie Mellon requests users of this software to return to
 *
 *  Software Distribution Coordinator  or  Software.Distribution@CS.CMU.EDU
 *  School of Computer Science
 *  Carnegie Mellon University
 *  Pittsburgh PA 15213-3890
 *
 * any improvements or extensions that they make and grant Carnegie the
 * rights to redistribute these changes.
 */

/******************************************************************************
 *
 * rf_raid5.c -- implements RAID Level 5
 *
 *****************************************************************************/

#include <dev/raidframe/rf_types.h>
#include <dev/raidframe/rf_raid.h>
#include <dev/raidframe/rf_raid5.h>
#include <dev/raidframe/rf_dag.h>
#include <dev/raidframe/rf_dagffrd.h>
#include <dev/raidframe/rf_dagffwr.h>
#include <dev/raidframe/rf_dagdegrd.h>
#include <dev/raidframe/rf_dagdegwr.h>
#include <dev/raidframe/rf_dagutils.h>
#include <dev/raidframe/rf_general.h>
#include <dev/raidframe/rf_map.h>
#include <dev/raidframe/rf_utils.h>

typedef struct RF_Raid5ConfigInfo_s {
	RF_RowCol_t **stripeIdentifier;	/* filled in at config time and used
					 * by IdentifyStripe */
}       RF_Raid5ConfigInfo_t;

int 
rf_ConfigureRAID5(
    RF_ShutdownList_t ** listp,
    RF_Raid_t * raidPtr,
    RF_Config_t * cfgPtr)
{
	RF_RaidLayout_t *layoutPtr = &raidPtr->Layout;
	RF_Raid5ConfigInfo_t *info;
	RF_RowCol_t i, j, startdisk;

	/* create a RAID level 5 configuration structure */
	RF_MallocAndAdd(info, sizeof(RF_Raid5ConfigInfo_t), (RF_Raid5ConfigInfo_t *), raidPtr->cleanupList);
	if (info == NULL)
		return (ENOMEM);
	layoutPtr->layoutSpecificInfo = (void *) info;

	RF_ASSERT(raidPtr->numRow == 1);

	/* the stripe identifier must identify the disks in each stripe, IN
	 * THE ORDER THAT THEY APPEAR IN THE STRIPE. */
	info->stripeIdentifier = rf_make_2d_array(raidPtr->numCol, raidPtr->numCol, raidPtr->cleanupList);
	if (info->stripeIdentifier == NULL)
		return (ENOMEM);
	startdisk = 0;
	for (i = 0; i < raidPtr->numCol; i++) {
		for (j = 0; j < raidPtr->numCol; j++) {
			info->stripeIdentifier[i][j] = (startdisk + j) % raidPtr->numCol;
		}
		if ((--startdisk) < 0)
			startdisk = raidPtr->numCol - 1;
	}

	/* fill in the remaining layout parameters */
	layoutPtr->numStripe = layoutPtr->stripeUnitsPerDisk;
	layoutPtr->bytesPerStripeUnit = layoutPtr->sectorsPerStripeUnit << raidPtr->logBytesPerSector;
	layoutPtr->numDataCol = raidPtr->numCol - 1;
	layoutPtr->dataSectorsPerStripe = layoutPtr->numDataCol * layoutPtr->sectorsPerStripeUnit;
	layoutPtr->numParityCol = 1;
	layoutPtr->dataStripeUnitsPerDisk = layoutPtr->stripeUnitsPerDisk;

	raidPtr->totalSectors = layoutPtr->stripeUnitsPerDisk * layoutPtr->numDataCol * layoutPtr->sectorsPerStripeUnit;

	return (0);
}

int 
rf_GetDefaultNumFloatingReconBuffersRAID5(RF_Raid_t * raidPtr)
{
	return (20);
}

RF_HeadSepLimit_t 
rf_GetDefaultHeadSepLimitRAID5(RF_Raid_t * raidPtr)
{
	return (10);
}
#if !defined(__NetBSD__) && !defined(__FreeBSD__) && !defined(_KERNEL)
/* not currently used */
int 
rf_ShutdownRAID5(RF_Raid_t * raidPtr)
{
	return (0);
}
#endif

void 
rf_MapSectorRAID5(
    RF_Raid_t * raidPtr,
    RF_RaidAddr_t raidSector,
    RF_RowCol_t * row,
    RF_RowCol_t * col,
    RF_SectorNum_t * diskSector,
    int remap)
{
	RF_StripeNum_t SUID = raidSector / raidPtr->Layout.sectorsPerStripeUnit;
	*row = 0;
	*col = (SUID % raidPtr->numCol);
	*diskSector = (SUID / (raidPtr->Layout.numDataCol)) * raidPtr->Layout.sectorsPerStripeUnit +
	    (raidSector % raidPtr->Layout.sectorsPerStripeUnit);
}

void 
rf_MapParityRAID5(
    RF_Raid_t * raidPtr,
    RF_RaidAddr_t raidSector,
    RF_RowCol_t * row,
    RF_RowCol_t * col,
    RF_SectorNum_t * diskSector,
    int remap)
{
	RF_StripeNum_t SUID = raidSector / raidPtr->Layout.sectorsPerStripeUnit;

	*row = 0;
	*col = raidPtr->Layout.numDataCol - (SUID / raidPtr->Layout.numDataCol) % raidPtr->numCol;
	*diskSector = (SUID / (raidPtr->Layout.numDataCol)) * raidPtr->Layout.sectorsPerStripeUnit +
	    (raidSector % raidPtr->Layout.sectorsPerStripeUnit);
}

void 
rf_IdentifyStripeRAID5(
    RF_Raid_t * raidPtr,
    RF_RaidAddr_t addr,
    RF_RowCol_t ** diskids,
    RF_RowCol_t * outRow)
{
	RF_StripeNum_t stripeID = rf_RaidAddressToStripeID(&raidPtr->Layout, addr);
	RF_Raid5ConfigInfo_t *info = (RF_Raid5ConfigInfo_t *) raidPtr->Layout.layoutSpecificInfo;

	*outRow = 0;
	*diskids = info->stripeIdentifier[stripeID % raidPtr->numCol];
}

void 
rf_MapSIDToPSIDRAID5(
    RF_RaidLayout_t * layoutPtr,
    RF_StripeNum_t stripeID,
    RF_StripeNum_t * psID,
    RF_ReconUnitNum_t * which_ru)
{
	*which_ru = 0;
	*psID = stripeID;
}
/* select an algorithm for performing an access.  Returns two pointers,
 * one to a function that will return information about the DAG, and
 * another to a function that will create the dag.
 */
void 
rf_RaidFiveDagSelect(
    RF_Raid_t * raidPtr,
    RF_IoType_t type,
    RF_AccessStripeMap_t * asmap,
    RF_VoidFuncPtr * createFunc)
{
	RF_RaidLayout_t *layoutPtr = &(raidPtr->Layout);
	RF_PhysDiskAddr_t *failedPDA = NULL;
	RF_RowCol_t frow, fcol;
	RF_RowStatus_t rstat;
	int     prior_recon;

	RF_ASSERT(RF_IO_IS_R_OR_W(type));

	if (asmap->numDataFailed + asmap->numParityFailed > 1) {
		RF_ERRORMSG("Multiple disks failed in a single group!  Aborting I/O operation.\n");
		 /* *infoFunc = */ *createFunc = NULL;
		return;
	} else
		if (asmap->numDataFailed + asmap->numParityFailed == 1) {

			/* if under recon & already reconstructed, redirect
			 * the access to the spare drive and eliminate the
			 * failure indication */
			failedPDA = asmap->failedPDAs[0];
			frow = failedPDA->row;
			fcol = failedPDA->col;
			rstat = raidPtr->status[failedPDA->row];
			prior_recon = (rstat == rf_rs_reconfigured) || (
			    (rstat == rf_rs_reconstructing) ?
			    rf_CheckRUReconstructed(raidPtr->reconControl[frow]->reconMap, failedPDA->startSector) : 0
			    );
			if (prior_recon) {
				RF_RowCol_t or = failedPDA->row, oc = failedPDA->col;
				RF_SectorNum_t oo = failedPDA->startSector;

				if (layoutPtr->map->flags & RF_DISTRIBUTE_SPARE) {	/* redirect to dist
											 * spare space */

					if (failedPDA == asmap->parityInfo) {

						/* parity has failed */
						(layoutPtr->map->MapParity) (raidPtr, failedPDA->raidAddress, &failedPDA->row,
						    &failedPDA->col, &failedPDA->startSector, RF_REMAP);

						if (asmap->parityInfo->next) {	/* redir 2nd component,
										 * if any */
							RF_PhysDiskAddr_t *p = asmap->parityInfo->next;
							RF_SectorNum_t SUoffs = p->startSector % layoutPtr->sectorsPerStripeUnit;
							p->row = failedPDA->row;
							p->col = failedPDA->col;
							p->startSector = rf_RaidAddressOfPrevStripeUnitBoundary(layoutPtr, failedPDA->startSector) +
							    SUoffs;	/* cheating:
									 * startSector is not
									 * really a RAID address */
						}
					} else
						if (asmap->parityInfo->next && failedPDA == asmap->parityInfo->next) {
							RF_ASSERT(0);	/* should not ever
									 * happen */
						} else {

							/* data has failed */
							(layoutPtr->map->MapSector) (raidPtr, failedPDA->raidAddress, &failedPDA->row,
							    &failedPDA->col, &failedPDA->startSector, RF_REMAP);

						}

				} else {	/* redirect to dedicated spare
						 * space */

					failedPDA->row = raidPtr->Disks[frow][fcol].spareRow;
					failedPDA->col = raidPtr->Disks[frow][fcol].spareCol;

					/* the parity may have two distinct
					 * components, both of which may need
					 * to be redirected */
					if (asmap->parityInfo->next) {
						if (failedPDA == asmap->parityInfo) {
							failedPDA->next->row = failedPDA->row;
							failedPDA->next->col = failedPDA->col;
						} else
							if (failedPDA == asmap->parityInfo->next) {	/* paranoid:  should
													 * never occur */
								asmap->parityInfo->row = failedPDA->row;
								asmap->parityInfo->col = failedPDA->col;
							}
					}
				}

				RF_ASSERT(failedPDA->col != -1);

				if (rf_dagDebug || rf_mapDebug) {
					printf("raid%d: Redirected type '%c' r %d c %d o %ld -> r %d c %d o %ld\n",
					       raidPtr->raidid, type, or, oc, 
					       (long) oo, failedPDA->row, 
					       failedPDA->col,
					       (long) failedPDA->startSector);
				}
				asmap->numDataFailed = asmap->numParityFailed = 0;
			}
		}
	/* all dags begin/end with block/unblock node therefore, hdrSucc &
	 * termAnt counts should always be 1 also, these counts should not be
	 * visible outside dag creation routines - manipulating the counts
	 * here should be removed */
	if (type == RF_IO_TYPE_READ) {
		if (asmap->numDataFailed == 0)
			*createFunc = (RF_VoidFuncPtr) rf_CreateFaultFreeReadDAG;
		else
			*createFunc = (RF_VoidFuncPtr) rf_CreateRaidFiveDegradedReadDAG;
	} else {


		/* if mirroring, always use large writes.  If the access
		 * requires two distinct parity updates, always do a small
		 * write.  If the stripe contains a failure but the access
		 * does not, do a small write. The first conditional
		 * (numStripeUnitsAccessed <= numDataCol/2) uses a
		 * less-than-or-equal rather than just a less-than because
		 * when G is 3 or 4, numDataCol/2 is 1, and I want
		 * single-stripe-unit updates to use just one disk. */
		if ((asmap->numDataFailed + asmap->numParityFailed) == 0) {
			if (rf_suppressLocksAndLargeWrites ||
			    (((asmap->numStripeUnitsAccessed <= (layoutPtr->numDataCol / 2)) && (layoutPtr->numDataCol != 1)) ||
				(asmap->parityInfo->next != NULL) || rf_CheckStripeForFailures(raidPtr, asmap))) {
				*createFunc = (RF_VoidFuncPtr) rf_CreateSmallWriteDAG;
			} else
				*createFunc = (RF_VoidFuncPtr) rf_CreateLargeWriteDAG;
		} else {
			if (asmap->numParityFailed == 1)
				*createFunc = (RF_VoidFuncPtr) rf_CreateNonRedundantWriteDAG;
			else
				if (asmap->numStripeUnitsAccessed != 1 && failedPDA->numSector != layoutPtr->sectorsPerStripeUnit)
					*createFunc = NULL;
				else
					*createFunc = (RF_VoidFuncPtr) rf_CreateDegradedWriteDAG;
		}
	}
}
OpenPOWER on IntegriCloud