summaryrefslogtreecommitdiffstats
path: root/share/man/man4/geom_fox.4
blob: d6d2112bf7f6fdb14b77b8a3d4db81b6807cbc0a (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
.\"
.\" Copyright (c) 2006 Wilko Bulte
.\" All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\"    notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\"    notice, this list of conditions and the following disclaimer in the
.\"    documentation and/or other materials provided with the distribution.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" $FreeBSD$
.\"
.Dd September 12, 2015
.Dt GEOM_FOX 4
.Os
.Sh NAME
.Nm geom_fox
.Nd "GEOM based basic disk multipathing"
.Sh SYNOPSIS
To compile this driver into the kernel,
place the following line in your
kernel configuration file:
.Bd -ragged -offset indent
.Cd "options GEOM_FOX"
.Ed
.Pp
Alternatively, to load the driver as a
module at boot time, place the following line in
.Xr loader.conf 5 :
.Bd -literal -offset indent
geom_fox_load="YES"
.Ed
.Sh DESCRIPTION
.Bf -symbolic
This driver is obsolete.
Users are advised to use
.Xr gmultipath 8
instead.
.Ef
.Pp
The intent of the
.Nm
framework is to provide basic multipathing support to access direct
access devices.
Basic in the above sentence should be read as:
.Nm
only provides path failover functionality, not load balancing over
the available paths etc.
Using suitable hardware like SCSI or FibreChannel disks it is
possible to have multiple (typically 2) host bus adapters access
the same physical disk drive.
.Pp
Without a multipathing driver the
.Fx
kernel would probe the disks multiple times, resulting in the creation of
multiple
.Pa /dev
entries for the same underlying physical device.
A unique label written in the GEOM label area allows
.Nm
to detect multiple paths.
Using this information it creates a unique
.Pa da#.fox
device.
.Pp
The
.Nm
device is subsequently used by the
.Fx
kernel to access the disks.
Multiple physical access paths ensure that even in case of a path failure the
.Fx
kernel can continue to access the data.
.Pp
The
.Nm
driver will disallow write operations to the underlying devices once the
fox device has been opened for writing.
.Sh EXAMPLES
.Bl -bullet -compact
.It
.Nm
needs a label on the disk as follows in order to work properly:
.Bd -literal
"0123456789abcdef0123456789abcdef"
"GEOM::FOX       <--unique--id-->"
.Ed
.Pp
For the unique ID 16 bytes are available.
The
.Dq Li GEOM::FOX
is the magic to mark a
.Nm
device.
.Pp
The actual labelling is accomplished by
.Bd -literal
echo "GEOM::FOX       someid" | dd of=/dev/da2 conv=sync
.Ed
.Pp
For FibreChannel devices it is suggested to use the Node World Wide
Name (Node WWN) as this is guaranteed by the FibreChannel standard to
be worldwide unique.
The use of the Port WWN not recommended as each port of a given
device has a different WWN, thereby confusing things.
.Pp
The Node WWN can be obtained from a verbose boot as in for example
.Bd -literal
isp1: Target 1 (Loop 0x1) Port ID 0xe8 (role Target) Arrived
 Port WWN 0x21000004cfc8aca2
 Node WWN 0x20000004cfc8aca2
.Ed
.Pp
This Node WWN would then be used like so:
.Bd -literal
echo "GEOM::FOX       20000004cfc8aca2" | dd of=/dev/da2 conv=sync
.Ed
.Pp
For non-FibreChannel devices you could for example use the serial
number of the device.
Regardless of what you use, make sure the label is unique.
.Pp
Once the labelling has been performed and assuming the
.Nm
module is loaded the kernel will inform you that it has found a new
.Nm
device with a message similar to
.Bd -literal
Creating new fox (da2)
fox da2.fox lock 0xfffffc0000fdba20
.Ed
.Pp
.It
To check which physical devices match a given
.Nm
device:
.Bd -literal -offset indent
# geom fox list
Geom name: da2.fox
Providers:
1. Name: da2.fox
   Mediasize: 73407865344 (68G)
   Sectorsize: 512
   Mode: r0w0e0
Consumers:
1. Name: da2
   Mediasize: 73407865856 (68G)
   Sectorsize: 512
   Mode: r0w0e0
2. Name: da6
   Mediasize: 73407865856 (68G)
   Sectorsize: 512
   Mode: r0w0e0
.Ed
.Pp
.It
To check the status of the
.Nm
components:
.Bd -literal
# geom fox status
   Name  Status  Components
da2.fox     N/A  da2
                 da6
.Ed
.El
.Sh SEE ALSO
.Xr GEOM 4 ,
.Xr geom 8 ,
.Xr gmultipath 8
.Sh AUTHORS
.An -nosplit
The
.Nm
driver was written by
.An "Poul-Henning Kamp" Aq phk@FreeBSD.org .
This manual page was written by
.An "Wilko Bulte" Aq wilko@FreeBSD.org .
.Sh CAVEATS
The
.Nm
driver depends on the underlying hardware drivers to do the right thing in case
of a path failure.
If for example a hardware driver continues to retry forever,
.Nm
is not able to re-initiate the I/O to an alternative physical path.
.Pp
You have to be very sure to provide a unique label for each of the
.Nm
devices.
Safety belts are not provided.
For FibreChannel devices it is suggested to use the Port WWN of the device.
The World Wide Name is guaranteed to be worldwide unique per the
FibreChannel standard.
.Sh BUGS
The
.Nm
framework has only seen light testing.
There definitely might be dragons here.
.Pp
The name
.Nm
is completely obscure.
Just remember that any sly fox has multiple exits from its hole.
.Pp
The examples provided are too FibreChannel-centric.