1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
|
.\" Copyright (c) 1990, 1991, 1993
.\" The Regents of the University of California. All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\" notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\" notice, this list of conditions and the following disclaimer in the
.\" documentation and/or other materials provided with the distribution.
.\" 3. All advertising materials mentioning features or use of this software
.\" must display the following acknowledgement:
.\" This product includes software developed by the University of
.\" California, Berkeley and its contributors.
.\" 4. Neither the name of the University nor the names of its contributors
.\" may be used to endorse or promote products derived from this software
.\" without specific prior written permission.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" @(#)startslip.1 8.1 (Berkeley) 6/5/93
.\" $FreeBSD$
.\"
.Dd June 5, 1993
.Dt STARTSLIP 1
.Os
.Sh NAME
.Nm startslip
.Nd dial up and login to a slip server
.Sh SYNOPSIS
.Nm
.Op Fl d
.Op Fl b Ar speed
.Oo
.Fl s Ar string1
.Op Fl s Ar string2 Op Ar ...\&
.Oc
.Op Fl h
.Op Fl l
.Op Fl L
.Op Fl A Ar annexname
.Op Fl U Ar upscript
.Op Fl D Ar downscript
.Op Fl t Ar script_timeout
.Op Fl W Ar maxtries
.Op Fl w Ar retry_pause
.Op Fl K Ar keepalive
.Op Fl O Ar outfill
.Op Fl S Ar unit
.Ar device user password
.Sh DESCRIPTION
The
.Nm
utility opens the specified
.Ar device .
Once carrier is asserted (if modem control is enabled)
.Nm
attempts to login as the specified
.Ar user
with the given
.Ar password .
Standard login: & Password: scheme assumed unless Annex option
specified (see
.Fl A ) .
If successful, it puts the device into the slip line discipline,
calls
.Ar upscript
and goes to wait mode.
If carrier drops (modem control enabled) or a
.Dv SIGHUP
is sent to
.Nm ,
it closes the device, calls
.Ar downscript
and attempts to repeat the dialup and login sequence.
If a
.Dv SIGTERM
is send to
.Nm ,
it closes the device, calls
.Ar downscript
and exits.
When
.Nm
called twice on the same device, previous copy killed by a
.Dv SIGTERM
before any operation.
.Pp
The following options are available:
.Bl -tag -width indent
.It Fl d
Print out debugging information.
.It Fl b Ar speed
Determine the baud rate used for
.Ar device ,
default value is 9600.
.It Fl t Ar script_timeout
Set login script timeout in seconds, default value is 90.
.It Fl w Ar retry_pause
Set connecting retry pause in seconds (increased from one retry to another),
default value is 60.
.It Fl W Ar maxtries
Set maximum number of connection retries for one session,
default value is 6.
Value 0 means infinite count.
.It Fl s Ar stringN
The optional
.Ar stringN
is written to
.Ar device .
Return character is added automatically.
For a dialup modem,
the string is used to specify a dial sequence.
No string written by default.
You can specify several
.Fl s Ar stringN
arguments to use with each try, f.e. several host phone numbers.
.It Fl A Ar annexname
The
.Nm
utility assumes it is connecting to a Xylogics Annex box and engages in an
appropriate dialog using the
.Ar user
and
.Ar password
arguments.
The
.Ar annexname
argument is a string that is used to match against the Annex prompt
to determine when a connection has been established.
.It Fl h
Use hardware (CTS/RTS) flow control for
.Ar device .
Default value is no flow control.
.It Fl l
Disable modem control (waiting for carrier and carrier drop sense) for
.Ar device .
Modem control is enabled by default.
.It Fl U Ar upscript
Specify a script to run when a SLIP interface becomes connected. This may
contain
.Xr ifconfig 8 ,
.Xr route 8 ,
and other appropriate commands. The arguments that
are passed to the script are "slX up".
Default value is
.Pa /sbin/ifconfig .
Dial sequence number (see
.Fl s )
passed via
.Ev LINE
environment variable.
.It Fl D Ar downscript
Specify a script to run when a SLIP connection goes away. The arguments that
are passed to the script are "slX down". Default value is
.Pa /sbin/ifconfig .
Dial sequence number (see
.Fl s )
passed via
.Ev LINE
environment variable.
.It Fl K Ar keepalive
Set SLIP "keep alive" timeout in seconds.
If FRAME_END not received during this
time period, a reconnect will occur.
Active "out fill" timeout expected from other
side.
Default value is no timeout.
.It Fl O Ar outfill
Set SLIP "out fill" timeout in seconds.
It causes at least one FRAME_END
to be sent during this timeout.
Needed for "keep alive" timeout on other side.
Default value is no timeout.
.It Fl S Ar unit
Set SLIP unit number directly.
Use with caution, no check for two
interfaces with same number made.
Default is dynamic assignment.
.It Fl L
Use uucp-style device locking.
You need it unless you start
.Nm
from external program which already does uucp locking.
Default case is no uucp locking to satisfy such programs.
.El
.Sh FILES
.Bl -tag -width /var/run/startslip.<device>.pid -compact
.It Pa /var/run/startslip.<device>.pid
pid stored here
.It Pa /usr/share/examples/startslip/*
.El
.Sh SEE ALSO
.Xr uustat 1 ,
.Xr slattach 8 ,
.Xr sliplogin 8
.Sh HISTORY
The
.Nm
appeared in
.Bx 4.4 .
|