1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
|
.\" Copyright (c) 2005 Chris Jones
.\" All rights reserved.
.\"
.\" This software was developed for the FreeBSD Project by Chris Jones
.\" thanks to the support of Google's Summer of Code program and
.\" mentoring by Lukas Ertl.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\" notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\" notice, this list of conditions and the following disclaimer in the
.\" documentation and/or other materials provided with the distribution.
.\"
.\" THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" $FreeBSD$
.\"
.Dd May 6, 2014
.Dt GVINUM 8
.Os
.Sh NAME
.Nm gvinum
.Nd Logical Volume Manager control program
.Sh SYNOPSIS
.Nm
.Op Ar command
.Op Fl options
.Sh COMMANDS
.Bl -tag -width indent
.It Ic attach Ar plex volume Op Cm rename
.It Ic attach Ar subdisk plex Oo Ar offset Oc Op Cm rename
Attach a plex to a volume, or a subdisk to a plex.
If offset is specified, the subdisk will be attached to the given offset within
the plex.
If rename is specified, the subdisk or plex will change name according to the
object it attaches to.
.It Ic checkparity Oo Fl f Oc Ar plex
Check the parity blocks of a RAID-5 plex.
The parity check will start at the
beginning of the plex if the
.Fl f
flag is specified, or otherwise at the location of the parity check pointer,
the first location at which plex's parity is incorrect.
All subdisks in the
plex must be up for a parity check.
.It Ic concat Oo Fl fv Oc Oo Fl n Ar name Oc Ar drives
Create a concatenated volume from the specified drives.
If no name is specified, a unique name will be set by
.Ic gvinum .
.It Ic create Oo Fl f Oc Op Ar description-file
Create a volume as described in
.Ar description-file .
If no
.Ar description-file
provided, opens an editor and provides the current
.Nm
configuration for editing.
The
.Fl f
flag will make gvinum ignore any errors regarding creating objects that already
exists.
However, in contrast to vinum, objects that are not properly named in the
.Ar description-file
will not be created when the
.Fl f
flag is given.
.It Ic detach Oo Fl f Oc Op Ar plex | subdisk
Detach a plex or subdisk from the volume or plex to which it is
attached.
.It Ic grow Ar plex device
Grow a plex by creating a gvinum drive and subdisk on device and attach it to
the plex.
If required by the plex organization, it will be put into the growable state.
.It Ic help
Provides a synopsis of
.Nm
commands and arguments.
.It Ic l | list Oo Fl rvV Oc Op Ar volume | plex | subdisk
.It Ic ld Oo Fl rvV Oc Op Ar drive ...
.It Ic ls Oo Fl rvV Oc Op Ar subdisk ...
.It Ic lp Oo Fl rvV Oc Op Ar plex ...
.It Ic lv Oo Fl rvV Oc Op Ar volume ...
List information about the relevant object(s).
The
.Fl r
flag provides recursive display, showing each object's subordinate objects in
proper relation.
The
.Fl v
and
.Fl V
flags provide progressively more detailed output.
.It Ic mirror Oo Fl fsv Oc Oo Fl n Ar name Oc Ar drives
Create a mirrored volume from the specified drives.
It requires at least a multiple of 2 drives.
If no name is specified, a unique name will be set by gvinum.
If the
.Fl s
flag is specified, a striped mirror will be created, and thus requires a
multiple of 4 drives.
.It Ic move | mv Fl f Ar drive subdisk Op Ar ...
Move the subdisk(s) to the specified drive.
The
.Fl f
flag is required, as all data on the indicated subdisk(s) will be destroyed as
part of the move.
This can currently only be done when the subdisk is
not being accessed.
.Pp
If a single subdisk is moved, and it forms a part of a RAID-5 plex, the moved
subdisks will need to be set to the
.Dq stale
state, and the plex will require a
.Ic start
command.
If multiple subdisk(s) is moved, and form part of a RAID-5 plex, the
moved disk(s) will need to be set to the
.Dq up
state and the plex will require a
.Ic rebuildparity
command.
If the subdisk(s) form part of a plex that is mirrored with other
plexes, the plex will require restarting and will sync once restarted.
Moving
more than one subdisk in a RAID-5 plex or subdisks from both sides of a
mirrored plex volume will destroy data.
Note that parity rebuilds and syncing
must be started manually after a move.
.It Ic printconfig
Write a copy of the current configuration to standard output.
.It Ic quit
Exit
.Nm
when running in interactive mode.
Normally this would be done by entering the
EOF character.
.It Ic raid5 Oo Fl fv Oc Oo Fl s Ar stripesize Oc Oo Fl n Ar name Oc Ar drives
Create a RAID-5 volume from the specified drives.
If no name is specified, a unique name will be set by
.Ic gvinum .
This organization requires at least three drives.
.It Ic rename Oo Fl r Oc Ar drive | subdisk | plex | volume newname
Change the name of the specified object.
The
.Fl r
flag will recursively rename subordinate objects.
.Pp
Note that device nodes will not be renamed until
.Nm
is restarted.
.It Ic rebuildparity Oo Fl f Oc Ar plex
Rebuild the parity blocks of a RAID-5 plex.
The parity rebuild will start at
the beginning of the plex if the
.Fl f
flag is specified, or otherwise at the location of the parity check pointer.
All subdisks in the plex must be up for a parity check.
.It Ic resetconfig Oo Fl f Oc
Reset the complete
.Nm
configuration.
.It Ic rm Oo Fl r Oc Ar volume | plex | subdisk
Remove an object and, if
.Fl r
is specified, its subordinate objects.
.It Ic saveconfig
Save
.Nm
configuration to disk after configuration failures.
.It Ic setstate Oo Fl f Oc Ar state volume | plex | subdisk | drive
Set state without influencing other objects, for diagnostic purposes
only.
The
.Fl f
flag forces state changes regardless of whether they are legal.
.It Ic start
Read configuration from all vinum drives.
.It Ic start Oo Fl S Ar size Oc Ar volume | plex | subdisk
Allow the system to access the objects.
If necessary, plexes will be synced and rebuilt.
If a subdisk was added to a running RAID-5 or striped plex, gvinum will
expand into this subdisk and grow the whole RAID-5 array.
This can be done without unmounting your filesystem.
The
.Fl S
flag is currently ignored.
.It Ic stop Oo Fl f Oc Op Ar volume | plex | subdisk
Terminate access to the objects, or stop
.Nm
if no parameters are specified.
.It Ic stripe Oo Fl fv Oc Oo Fl n Ar name Oc Ar drives
Create a striped volume from the specified drives. If no name is specified,
a unique name will be set by
.Ic gvinum .
This organization requires at least two drives.
.El
.Sh DESCRIPTION
The
.Nm
utility communicates with the kernel component of the GVinum logical volume
manager.
It is designed either for interactive use, when started without
command line arguments, or to execute a single command if the command is
supplied on the command line.
In interactive mode,
.Nm
maintains a command line history.
.Sh OPTIONS
The
.Nm
commands may be followed by an option.
.Bl -tag -width indent
.It Fl f
The
.Fl f
.Pq Dq force
option overrides safety checks.
It should be used with extreme caution.
This
option is required in order to use the
.Ic move
command.
.It Fl r
The
.Fl r
.Pq Dq recursive
option applies the command recursively to subordinate objects.
For example, in
conjunction with the
.Ic lv
command, the
.Fl r
option will also show information about the plexes and subdisks belonging to
the volume.
It is also used by the
.Ic rename
command to indicate that subordinate objects such as subdisks should be renamed
to match the object(s) specified and by the
.Ic rm
command to delete plexes belonging to a volume and so on.
.It Fl v
The
.Fl v
.Pq Dq verbose
option provides more detailed output.
.It Fl V
The
.Fl V
.Pq Dq "very verbose"
option provides even more detailed output than
.Fl v .
.El
.Sh ENVIRONMENT
.Bl -tag -width ".Ev EDITOR"
.It Ev EDITOR
The name of the editor to use for editing configuration files, by
default
.Xr vi 1
is invoked.
.El
.Sh FILES
.Bl -tag -width ".Pa /dev/gvinum/plex"
.It Pa /dev/gvinum
directory with device nodes for
.Nm
objects
.El
.Sh EXAMPLES
To create a mirror on disks /dev/ada1 and /dev/ada2, create a filesystem,
mount, unmount and then stop
.Ic gvinum :
.Pp
.Dl "gvinum mirror /dev/ada1 /dev/ada2"
.Dl "newfs /dev/gvinum/gvinumvolume0"
.Dl "mount /dev/gvinum/gvinumvolume0 /mnt"
.Dl "..."
.Dl "unmount /mnt"
.Dl "gvinum stop"
.Pp
To create a striped mirror on disks /dev/ada1 /dev/ada2 /dev/ada3 and
/dev/ada4 named "data" and create a filesystem:
.Pp
.Dl "gvinum mirror -s -n data /dev/ada1 /dev/ada2 /dev/ada3 /dev/ada4"
.Dl "newfs /dev/gvinum/data"
.Pp
To create a raid5 array on disks /dev/ada1 /dev/ada2 and /dev/ada3,
with stripesize 493k you can use the raid5 command:
.Pp
.Dl "gvinum raid5 -s 493k /dev/ada1 /dev/ada2 /dev/ada3"
.Pp
Then the volume will be created automatically.
Afterwards, you have to initialize the volume:
.Pp
.Dl "gvinum start myraid5vol"
.Pp
The initialization will start, and the states will be updated when it's
finished.
The list command will give you information about its progress.
.Pp
Imagine that one of the drives fails, and the output of 'printconfig' looks
something like this:
.Pp
.Dl "drive gvinumdrive1 device /dev/ada2"
.Dl "drive gvinumdrive2 device /dev/???"
.Dl "drive gvinumdrive0 device /dev/ada1"
.Dl "volume myraid5vol"
.Dl "plex name myraid5vol.p0 org raid5 986s vol myraid5vol"
.Dl "sd name myraid5vol.p0.s2 drive gvinumdrive2 len 32538s driveoffset 265s"
.Dl "plex myraid5vol.p0 plexoffset 1972s"
.Dl "sd name myraid5vol.p0.s1 drive gvinumdrive1 len 32538s driveoffset 265s"
.Dl "plex myraid5vol.p0 plexoffset 986s"
.Dl "sd name myraid5vol.p0.s0 drive gvinumdrive0 len 32538s driveoffset 265s"
.Dl "plex myraid5vol.p0 plexoffset 0s"
.Pp
Create a new drive with this configuration:
.Pp
.Dl "drive gdrive4 device /dev/ada4"
.Pp
Then move the stale subdisk to the new drive:
.Pp
.Dl "gvinum move gdrive4 myraid5vol.p0.s2"
.Pp
Then, initiate the rebuild:
.Pp
.Dl "gvinum start myraid5vol.p0"
.Pp
The plex will go up form degraded mode after the rebuild is finished.
The plex can still be used while the rebuild is in progress, although requests
might be delayed.
.Pp
Given the configuration as in the previous example, growing a RAID-5 or STRIPED
array is accomplished by using the grow command:
.Pp
.Dl "gvinum grow myraid5vol.p0 /dev/ada4"
.Pp
If everything went ok, the plex state should now be set to growable.
You can then start the growing with the
.Ic start
command:
.Pp
.Dl "gvinum start myraid5vol.p0"
.Pp
As with rebuilding, you can watch the progress using the
.Ic list
command.
.Pp
For a more advanced usage and detailed explanation of gvinum, the
handbook is recommended.
.Sh SEE ALSO
.Xr geom 4 ,
.Xr geom 8
.Sh HISTORY
The
.Nm
utility first appeared in
.Fx 5.3 .
The
.Nm vinum
utility, on which
.Nm
is based, was written by
.An "Greg Lehey" .
.Pp
The
.Nm
utility
was written by
.An "Lukas Ertl" .
The
.Ic move
and
.Ic rename
commands and
documentation were added by
.An "Chris Jones"
through the 2005 Google Summer
of Code program.
A partial rewrite of gvinum was done by
.An "Lukas Ertl"
and
.An "Ulf Lilleengen"
through the 2007 Google Summer of Code program.
The documentation have been updated to reflect the new functionality.
.Sh AUTHORS
.An Lukas Ertl Aq le@FreeBSD.org
.An Chris Jones Aq soc-cjones@FreeBSD.org
.An Ulf Lilleengen Aq lulf@FreeBSD.org
.Sh BUGS
Currently,
.Nm
does not rename devices in
.Pa /dev/gvinum
until reloaded.
.Pp
The
.Fl S
initsize flag to
.Ic start
is ignored.
.Pp
Moving subdisks that are not part of a mirrored or RAID-5 volume will
destroy data.
It is perhaps a bug to permit this.
.Pp
Plexes in which subdisks have been moved do not automatically sync or
rebuild parity.
This may leave data unprotected and is perhaps unwise.
.Pp
Currently,
.Nm
does not yet fully implement all of the functions found in
.Nm vinum .
Specifically, the following commands from
.Nm vinum
are not supported:
.Bl -tag -width indent
.It Ic debug
Cause the volume manager to enter the kernel debugger.
.It Ic debug Ar flags
Set debugging flags.
.It Ic dumpconfig Op Ar drive ...
List the configuration information stored on the specified drives, or all
drives in the system if no drive names are specified.
.It Ic info Op Fl vV
List information about volume manager state.
.It Ic label Ar volume
Create a volume label.
.It Ic resetstats Oo Fl r Oc Op Ar volume | plex | subdisk
Reset statistics counters for the specified objects, or for all objects if none
are specified.
.It Ic setdaemon Op Ar value
Set daemon configuration.
.El
|