summaryrefslogtreecommitdiffstats
path: root/contrib/wpa/wpa_supplicant/examples/p2p/p2p_stop_find.py
blob: f6c03b0272282a32a268064e83cfcddeaacac03d (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
#!/usr/bin/python
# Tests p2p_stop_find
######### MAY NEED TO RUN AS SUDO #############

import dbus
import sys, os
import time
import gobject
import threading
import getopt
from dbus.mainloop.glib import DBusGMainLoop

def usage():
	print "Usage:"
	print "  %s -i <interface_name> \ " \
		% sys.argv[0]
	print "  		[-w <wpas_dbus_interface>]"
	print "Options:"
	print "  -i = interface name"
	print "  -w = wpas dbus interface = fi.w1.wpa_supplicant1"
	print "Example:"
	print "  %s -i wlan0" % sys.argv[0]

# Required Signals
def deviceLost(devicepath):
	print "Device lost: %s" % (devicepath)

def p2pStateChange(status):
	print status
	os._exit(0)

class P2P_Stop_Find (threading.Thread):
	# Needed Variables
	global bus
	global wpas_object
	global interface_object
	global p2p_interface
	global interface_name
	global wpas
	global wpas_dbus_interface
	global path
	global timeout

	# Dbus Paths
	global wpas_dbus_opath
	global wpas_dbus_interfaces_opath
	global wpas_dbus_interfaces_interface
	global wpas_dbus_interfaces_p2pdevice

	# Constructor
	def __init__(self,interface_name,wpas_dbus_interface,timeout):
		# Initializes variables and threads
		self.interface_name = interface_name
		self.wpas_dbus_interface = wpas_dbus_interface
		self.timeout = timeout

		# Initializes thread and daemon allows for ctrl-c kill
		threading.Thread.__init__(self)
		self.daemon = True

		# Generating interface/object paths
		self.wpas_dbus_opath = "/" + \
				self.wpas_dbus_interface.replace(".","/")
		self.wpas_wpas_dbus_interfaces_opath = self.wpas_dbus_opath + \
				"/Interfaces"
		self.wpas_dbus_interfaces_interface = \
				self.wpas_dbus_interface + ".Interface"
		self.wpas_dbus_interfaces_p2pdevice = \
				self.wpas_dbus_interfaces_interface \
				+ ".P2PDevice"

		# Getting interfaces and objects
		DBusGMainLoop(set_as_default=True)
		self.bus = dbus.SystemBus()
		self.wpas_object = self.bus.get_object(
				self.wpas_dbus_interface,
				self.wpas_dbus_opath)
		self.wpas = dbus.Interface(self.wpas_object,
				self.wpas_dbus_interface)

		# Try to see if supplicant knows about interface
		# If not, throw an exception
		try:
			self.path = self.wpas.GetInterface(
					self.interface_name)
		except dbus.DBusException, exc:
			error = 'Error:\n  Interface ' + self.interface_name \
				+ ' was not found'
			print error
			usage()
			os._exit(0)

		self.interface_object = self.bus.get_object(
				self.wpas_dbus_interface, self.path)
		self.p2p_interface = dbus.Interface(self.interface_object,
				self.wpas_dbus_interfaces_p2pdevice)

		# Signals
		self.bus.add_signal_receiver(deviceLost,
			dbus_interface=self.wpas_dbus_interfaces_p2pdevice,
			signal_name="DeviceLost")
		self.bus.add_signal_receiver(p2pStateChange,
			dbus_interface=self.wpas_dbus_interfaces_p2pdevice,
			signal_name="P2PStateChanged")

	# Runs p2p_stop_find
	def run(self):
		# Allows other threads to keep working while MainLoop runs
		# Required for timeout implementation
		gobject.MainLoop().get_context().iteration(True)
		gobject.threads_init()
		self.p2p_interface.StopFind()
		gobject.MainLoop().run()


if __name__ == "__main__":
	# Needed because P2PStateChanged signal is not caught
	timeout = 5
	# Defaults for optional inputs
	wpas_dbus_interface = 'fi.w1.wpa_supplicant1'

	# interface_name is required
	interface_name = None

	# Using getopts to handle options
	try:
		options, args = getopt.getopt(sys.argv[1:],"ht:i:w:")

	except getopt.GetoptError:
		usage()
		quit()

	# If theres a switch, override default option
	for key, value in options:
		# Help
		if (key == "-h"):
			usage()
			quit()
		# Interface Name
		elif (key == "-i"):
			interface_name = value
		# Dbus interface
		elif (key == "-w"):
			wpas_dbus_interface = value
		else:
			assert False, "unhandled option"

	# Interface name is required and was not given
	if (interface_name == None):
		print "Error:\n  interface_name is required"
		usage()
		quit()

	# Constructor
	try:
		p2p_stop_find_test = P2P_Stop_Find(interface_name,
						wpas_dbus_interface,timeout)

	except:
		print "Error:\n  Invalid wpas_dbus_interface"
		usage()
		quit()

	# Start P2P_Find
	p2p_stop_find_test.start()

	try:
		time.sleep(int(p2p_stop_find_test.timeout))

	except:
		pass

	print "p2p find stopped"
	quit()
OpenPOWER on IntegriCloud