-.\" Copyright (c) 2000 Michael Smith
-.\" All rights reserved.
-.\"
-.\" Redistribution and use in source and binary forms, with or without
-.\" modification, are permitted provided that the following conditions
-.\" are met:
-.\" 1. Redistributions of source code must retain the above copyright
-.\" notice, this list of conditions and the following disclaimer.
-.\" 2. The name of the author may not be used to endorse or promote products
-.\" derived from this software without specific prior written permission
-.\"
-.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
-.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
-.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
-.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
-.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
-.\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
-.\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
-.\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
-.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
-.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
-.\"
-.\" $FreeBSD$
-.\"
-.Dd April 10, 2000
-.Dt MLXCONTROL 8
-.Os
-.Sh NAME
-.Nm mlxcontrol
-.Nd Mylex DAC-family RAID management utility
-.Sh SYNOPSIS
-.Nm
-.Aq command
-.Op args
-.Nm
-status
-.Op Fl qv
-.Op Ar drive
-.Nm
-rescan
-.Ar controller
-.Op Ar controller ...
-.Nm
-detach
-.Ar drive
-.Op Ar drive ...
-.Nm
-detach
-.Fl a
-.Nm
-check
-.Ar drive
-.Nm
-config
-.Ar controller
-.Nm
-help
-.Ar command
-.Sh DESCRIPTION
-The
-.Nm
-utility provides status monitoring and management functions
-for devices attached
-to the
-.Xr mlx 4
-driver.
-.Pp
-Controller names are of the form "mlxN"
-where N is the unit number of the controller.
-Drive names are of the form "mlxdN"
-where N is the unit number of the drive.
-Do not specify the path to a device node.
-.Bl -tag -width rebuild
-.It status
-Print the status of controllers and system drives.
-If one or more drives are specified,
-only print information about these drives,
-otherwise print information
-about all controllers and drives in the system.
-With the
-.Fl v
-flag, display much more verbose information.
-With the
-.Fl q
-flag, do not print any output.
-This command returns
-0 if all drives tested are online,
-1 if one or more drives are critical and
-2 if one or more are offline.
-.It rescan
-Rescan one or more controllers for non-attached system drives
-(e.g.\& drives that have been
-detached or created subsequent to driver initialisation).
-If the
-.Fl a
-flag is supplied, rescan all controllers in the system.
-.It detach
-Detach one or more system drives.
-Drives must be unmounted
-and not opened by any other utility for this command to succeed.
-If the
-.Fl a
-flag is supplied, detach all system drives from the nominated controller.
-.It check
-Initiate a consistency check and repair pass on a redundant system drive
-(e.g.\& RAID1 or RAID5).
-The controller will scan the system drive and repair any inconsistencies.
-This command returns immediately;
-use the
-.Ar status
-command to monitor the progress of the check.
-.It rebuild
-Requires two arguments,
-.Ar controller
-and
-.Ar physdrive
-as specified in the
-output of the
-.Ar status
-command.
-All system drives using space on the physical drive
-.Ar physdrive
-are rebuilt, reconstructing all data on the drive.
-Note that each controller can only perform one rebuild at a time.
-This command returns immediately; use the
-.Ar status
-command to monitor the progress of the rebuild.
-.It config
-Print the current configuration from the nominated controller.
-This command will be updated
-to allow addition/deletion of system drives from a configuration
-in a future release.
-.It help
-Print usage information for
-.Ar command .
-.El
-.Sh AUTHORS
-The mlxcontrol utility was written by
-.An Michael Smith
-.Aq msmith@FreeBSD.org .
-.Sh BUGS
-The
-.Ar config
-command does not yet support modifying system drive configuration.
-.Pp
-Error log extraction is not yet supported.