summaryrefslogtreecommitdiffstats
path: root/sys/nfs
diff options
context:
space:
mode:
Diffstat (limited to 'sys/nfs')
-rw-r--r--sys/nfs/nfs.h12
-rw-r--r--sys/nfs/nfs_common.c11
-rw-r--r--sys/nfs/nfs_subs.c11
3 files changed, 0 insertions, 34 deletions
diff --git a/sys/nfs/nfs.h b/sys/nfs/nfs.h
index 2d009a1..e07a4f5 100644
--- a/sys/nfs/nfs.h
+++ b/sys/nfs/nfs.h
@@ -114,18 +114,6 @@
#endif
/*
- * Expected allocation sizes for major data structures. If the actual size
- * of the structure exceeds these sizes, then malloc() will be allocating
- * almost twice the memory required. This is used in nfs_init() to warn
- * the sysadmin that the size of a structure should be reduced.
- * (These sizes are always a power of 2. If the kernel malloc() changes
- * to one that does not allocate space in powers of 2 size, then this all
- * becomes bunk!)
- */
-#define NFS_SVCALLOC 256
-#define NFS_UIDALLOC 128
-
-/*
* Arguments to mount NFS
*/
#define NFS_ARGSVERSION 3 /* change when nfs_args changes */
diff --git a/sys/nfs/nfs_common.c b/sys/nfs/nfs_common.c
index 50bd75a..28fce31 100644
--- a/sys/nfs/nfs_common.c
+++ b/sys/nfs/nfs_common.c
@@ -1107,17 +1107,6 @@ nfs_init(vfsp)
nfsmount_zone = zinit("NFSMOUNT", sizeof(struct nfsmount), 0, 0, 1);
- /*
- * Check to see if major data structures haven't bloated.
- */
- if (sizeof (struct nfssvc_sock) > NFS_SVCALLOC) {
- printf("struct nfssvc_sock bloated (> %dbytes)\n",NFS_SVCALLOC);
- printf("Try reducing NFS_UIDHASHSIZ\n");
- }
- if (sizeof (struct nfsuid) > NFS_UIDALLOC) {
- printf("struct nfsuid bloated (> %dbytes)\n",NFS_UIDALLOC);
- printf("Try unionizing the nu_nickname and nu_flag fields\n");
- }
nfs_mount_type = vfsp->vfc_typenum;
nfsrtt.pos = 0;
rpc_vers = txdr_unsigned(RPC_VER2);
diff --git a/sys/nfs/nfs_subs.c b/sys/nfs/nfs_subs.c
index 50bd75a..28fce31 100644
--- a/sys/nfs/nfs_subs.c
+++ b/sys/nfs/nfs_subs.c
@@ -1107,17 +1107,6 @@ nfs_init(vfsp)
nfsmount_zone = zinit("NFSMOUNT", sizeof(struct nfsmount), 0, 0, 1);
- /*
- * Check to see if major data structures haven't bloated.
- */
- if (sizeof (struct nfssvc_sock) > NFS_SVCALLOC) {
- printf("struct nfssvc_sock bloated (> %dbytes)\n",NFS_SVCALLOC);
- printf("Try reducing NFS_UIDHASHSIZ\n");
- }
- if (sizeof (struct nfsuid) > NFS_UIDALLOC) {
- printf("struct nfsuid bloated (> %dbytes)\n",NFS_UIDALLOC);
- printf("Try unionizing the nu_nickname and nu_flag fields\n");
- }
nfs_mount_type = vfsp->vfc_typenum;
nfsrtt.pos = 0;
rpc_vers = txdr_unsigned(RPC_VER2);
OpenPOWER on IntegriCloud