diff options
Diffstat (limited to 'share/man/man5/rc.conf.5')
-rw-r--r-- | share/man/man5/rc.conf.5 | 114 |
1 files changed, 114 insertions, 0 deletions
diff --git a/share/man/man5/rc.conf.5 b/share/man/man5/rc.conf.5 index 14c00a7..6ac4cc0 100644 --- a/share/man/man5/rc.conf.5 +++ b/share/man/man5/rc.conf.5 @@ -1964,6 +1964,120 @@ by default. Flags for .Xr isdntrace 8 . .\" ----------------------------------------------------- +.It Va pcvt_verbose +.Pq Vt bool +Set to +.Dq Li NO +by default. +When set to +.Dq Li YES , +verbose messages about the actions done by the start script are displayed. +.Em Note: +the pcvt driver must be comiled into the kernel before the pcvt related +options described here take any effect. +.It Va pcvt_keymap +.Pq Vt str +Set to +.Dq Li NO +by default. +Use this to configure a national keyboard mapping found in the +.Pa /usr/share/misc/keycap.pcvt +file of keyboard mappings. +(see also the manual pages +.Xr keycap 5 +and +.Xr keycap 3 +for usage of pcvt's keycap database and the manual page +.Xr kcon 1 +option -m for national keyboard mapping configuration). +.It Va pcvt_keydel +.Pq Vt int +Set to +.Dq Li NO +by default. +Used to set the keyboard key repeat delay value. Valid values are +in the range 0..3 for delay values of 250, 500, 750 and 1000 msec. +(See also the +.Xr kcon 1 +manual page). +.It Va pcvt_keyrate +.Pq Vt int +Set to +.Dq Li NO +by default. +Used to set the keyboard key repetition rate value. Valid values are +in the range 0..31 for repetition values of 2..30 characters per second. +.It Va pcvt_keyrepeat +.Pq Vt bool +Set to +.Dq Li NO +by default. +Set to +.Dq Li YES +to enable automatic keyboard key repeating. +.It Va pcvt_force24 +.Pq Vt bool +Set to +.Dq Li NO +by default. +Set to +.Dq Li YES +to force pcvt to use 24 lines only (in 25 lines mode) for compatibility +with the original VT220 terminal. +.It Va pcvt_hpext +.Pq Vt bool +Set to +.Dq Li NO +by default. +Set to +.Dq Li YES +to enable the display and funtionality of function key labels (as found +on Hewlett-Packard terminals such as the HP2392A and the HP700/92 in +ANSI mode). +.It Va pcvt_lines +.Pq Vt int +Set to +.Dq Li NO +by default resulting in a value of 25. +Used to set the number of lines on the screen. For VGA displays, valid +values are 25, 28, 40 and 50 lines. +(See also the +.Xr scon 1 +manual page). +.It Va pcvt_blanktime +.Pq Vt int +Set to +.Dq Li NO +by default. +Used to set the screen saver timeout in seconds for values greater than +zero. +.It Va pcvt_cursorh +.Pq Vt int +Set to +.Dq Li NO +by default. +Used to set the cursor top scanline. +(See also the +.Xr cursor 1 +manual page). +.It Va pcvt_cursorl +.Pq Vt int +Set to +.Dq Li NO +by default. +Used to set the cursor bottom scanline. +.It Va pcvt_monohigh +.Pq Vt bool +Set to +.Dq Li NO +by default. +Set to +.Dq Li YES +to set intensity to high on monochrome monitors. +(See also the +.Xr scon 1 +manual page, option -p, for more information on changing VGA palette +values). .El .Sh FILES .Bl -tag -width ".Pa /etc/defaults/rc.conf" -compact |