summaryrefslogtreecommitdiffstats
path: root/share/examples/atm/Startup
diff options
context:
space:
mode:
Diffstat (limited to 'share/examples/atm/Startup')
-rw-r--r--share/examples/atm/Startup127
1 files changed, 0 insertions, 127 deletions
diff --git a/share/examples/atm/Startup b/share/examples/atm/Startup
deleted file mode 100644
index 8898e45..0000000
--- a/share/examples/atm/Startup
+++ /dev/null
@@ -1,127 +0,0 @@
-HARP ATM Startup Configuration Instructions
-===========================================
-
-The following steps are required in order to use the HARP ATM software.
-See the file atm-config.sh for an example ATM startup script.
-
-1. Each ATM physical interface must be configured with one or more network
- interfaces. The physical interfaces are named:
-
- FORE Systems: hfa0, hfa1, ...
- Efficient Networks: hea0, hea1, ...
-
- The network interface names and the number of network interfaces for a
- particular physical interface are specified via the atm command. The
- network interface name prefix may be any alphabetic string, but the
- generated network interface names must be unique amongst all network
- interfaces, including non-ATM interfaces.
-
- To configure the network interfaces, type:
-
- atm set netif <interface_name> <netif_prefix> <netif_count>
-
- For example, the command:
-
- atm set netif hfa0 ni 3
-
- will generate the network interfaces ni0, ni1 and ni2 on the physical
- interface hfa0.
-
- For further details, see the man page atm(8).
-
-
-2. Each ATM network interface (netif) must be configured with an IP network
- address. Each network interface must be on a different IP subnet.
-
- To configure the network interface, type:
-
- ifconfig <netif_name> <IP_address> up
-
-
-3. Each ATM physical interface must have a signalling manager attached. The
- interfaces may have the same or different signalling managers.
-
- To attach a signalling manager, type:
-
- atm attach <interface_name> <signalling_manager_name>
-
- where <signalling_manager_name> may be:
-
- sigpvc - to only support PVCs on the interface;
- spans - to run FORE Systems SPANS signalling protocol across
- the interface, plus support of PVCs;
- uni30 - to run ATM Forum UNI 3.0 signalling protocol across
- the interface, plus support of PVCs;
- uni31 - to run ATM Forum UNI 3.1 signalling protocol across
- the interface, plus support of PVCs;
-
- For further details, see the man page atm(8).
-
-
-4. Each of the host's PVCs (if any) must be defined.
-
- To define a PVC, type:
-
- atm add pvc <interface_name> <vpi> <vci> <aal> <encaps> <owner> ....
-
- where <interface_name> is the name of the ATM physical interface
- over which the PVC is being defined;
- <vpi> is the VPI value for the PVC;
- <vci> is the VCI value for the PVC;
- <aal> is the AAL type which the PVC endpoints will use;
- <encaps> is the encapsulation which the PVC endpoints will use;
- <owner> specifies the the owner of the PVC, which may be:
- ip - the PVC is used for IP traffic;
-
- additional parameters may be required, depending on the PVC owner:
-
- for owner=ip,
- <netif_name> is the name of the PVC's network interface;
- <dst> specifies the IP address at the remote end of this PVC;
-
- For further details, see the man page atm(8).
-
-
-5. HARP includes an ILMI daemon, which will perform host address registration
- with the ATM switch for ATM Forum UNI interfaces. If ILMI support is
- available and activated in the ATM switch and the ILMI daemon is running
- (see ilmid(8)), no further registration procedures are required.
- The 'atm set prefix' command is not needed in this case.
-
- If ILMI address registration support is not available or activated, then
- the host must be manually registered with its switch. There should be
- a user command available on the switch in order to do the registration.
-
- For example, if you are using a FORE Systems switch, you should enter
- the following AMI command:
-
- > conf nsap route new <host_nsap> 152 <switch_port> 0
-
- If you are using a Cisco LightStream 1010 switch, you would use the
- following configuration command:
-
- > atm route <host_nsap> atm <atm_interface_#> internal
-
- For ATM Forum UNI interfaces, the 'atm set prefix' command must also
- be issued when not using ILMI address registration.
-
-
-6. HARP includes support for the Server Cache Synchronization Protocol (SCSP),
- which can synchronize the ATMARP caches of multiple ATMARP servers.
- Obviously, this is only useful on hosts which are ATMARP servers.
-
- To run SCSP between servers, two daemons, scspd and atmarpd, must be
- started. Scspd implements the SCSP protocol and atmarpd provides an
- interface between scspd and the ATMARP server in the kernel. Scspd
- requires a configuration file. It will look for a configuration
- file at /etc/scspd.conf unless told otherwise.
-
- An example of commands to start the two daemons is:
-
- # scspd
- # atmarpd <netif>
-
- See the man pages scspd(8) and atmarpd(8) for further information.
-
- @(#) $FreeBSD$
-
OpenPOWER on IntegriCloud