summaryrefslogtreecommitdiffstats
path: root/sbin/camcontrol/camcontrol.8
diff options
context:
space:
mode:
Diffstat (limited to 'sbin/camcontrol/camcontrol.8')
-rw-r--r--sbin/camcontrol/camcontrol.816
1 files changed, 8 insertions, 8 deletions
diff --git a/sbin/camcontrol/camcontrol.8 b/sbin/camcontrol/camcontrol.8
index f26cb4c..dde3e19 100644
--- a/sbin/camcontrol/camcontrol.8
+++ b/sbin/camcontrol/camcontrol.8
@@ -547,7 +547,7 @@ information if the command fails since the
.Fl v
switch was not specified.
.Pp
-.Bd -literal -offset foobar
+.Bd -literal -offset indent
camcontrol tur da1 -E -C 4 -t 50 -v
.Ed
.Pp
@@ -559,7 +559,7 @@ flag) if the command fails. Since error recovery is turned on, the
disk will be spun up if it is not currently spinning.
.Nm camcontrol
will report whether the disk is ready.
-.Bd -literal -offset foobar
+.Bd -literal -offset indent
camcontrol cmd -n cd -u 1 -v -c "3C 00 00 00 00 00 00 00 0e 00" \e
-i 0xe "s1 i3 i1 i1 i1 i1 i1 i1 i1 i1 i1 i1"
.Ed
@@ -568,7 +568,7 @@ Issue a READ BUFFER command (0x3C) to cd1. Display the buffer size of cd1,
and display the first 10 bytes from the cache on cd1. Display SCSI sense
information if the command fails.
.Pp
-.Bd -literal -offset foobar
+.Bd -literal -offset indent
camcontrol cmd -n cd -u 1 -v -c "3B 00 00 00 00 00 00 00 0e 00" \e
-o 14 "00 00 00 00 1 2 3 4 5 6 v v v v" 7 8 9 8
.Ed
@@ -578,7 +578,7 @@ not including the (reserved) 4 byte header. Print out sense information if
the command fails. Be very careful with this command, improper use may
cause data corruption.
.Pp
-.Bd -literal -offset foobar
+.Bd -literal -offset indent
camcontrol modepage da3 -m 1 -e -P 3
.Ed
.Pp
@@ -599,20 +599,20 @@ changed.
.Pp
Set the number of concurrent transactions for da5 to 24.
.Pp
-.Bd -literal -offset foobar
+.Bd -literal -offset indent
camcontrol negotiate -n da -u 4 -T disable
.Ed
.Pp
Disable tagged queueing for da4.
.Pp
-.Bd -literal -offset foobar
+.Bd -literal -offset indent
camcontrol negotiate -n da -u 3 -R 20.000 -O 15 -a
.Ed
.Pp
Negotiate a sync rate of 20MHz and an offset of 15 with da3. Then send a
Test Unit Ready command to make the settings take effect.
.Pp
-.Bd -literal -offset foobar
+.Bd -literal -offset indent
camcontrol cmd -n da -u 3 -v -t 7200 -c "4 0 0 0 0 0"
.Ed
.Pp
@@ -667,7 +667,7 @@ in
The code that parses the generic command line arguments doesn't know that
some of the subcommands take multiple arguments. So if, for instance, you
tried something like this:
-.Bd -literal -offset foobar
+.Bd -literal -offset indent
camcontrol cmd -n da -u 1 -c "00 00 00 00 00 v" 0x00 -v
.Ed
.Pp
OpenPOWER on IntegriCloud